1. Introduction

The YE2 series high-efficiency three-phase asynchronous motor represents a pivotal milestone in China's industrial motor evolution — bridging the gap between legacy standard-efficiency designs and modern premium-efficiency requirements. Developed in response to GB 18613-2012 (China's mandatory motor energy efficiency standard) and harmonized with IEC 60034-30-1 IE2 international efficiency classification, the YE2 series established the foundation for energy-conscious motor design in the Chinese manufacturing sector.

While subsequent regulatory updates (notably GB 18613-2020, effective June 1, 2021) have elevated the minimum efficiency requirement from IE2 to IE3 for most general-purpose motors, the YE2 series remains extensively deployed across existing industrial infrastructure, export markets with IE2 acceptance, and applications where IE2 represents the optimal balance of efficiency and capital cost. Understanding the YE2 series is therefore essential for maintenance engineers, procurement professionals, and system designers operating across diverse regulatory environments.

2. Regulatory Framework & Efficiency Classification

2.1 IEC 60034-30-1 Efficiency Classes

Efficiency ClassDesignationTypical Full-Load EfficiencyLoss Reduction vs. IE1Regulatory Status
IE1Standard Efficiency91.7%BaselinePhased out in EU, China
IE2High Efficiency93.2%~20% lowerMandatory in some regions
IE3Premium Efficiency94.5%~35% lowerMandatory in EU, China
IE4Super Premium95.6%~50% lowerVoluntary premium
IE5Ultra-Premium96.7%~60% lowerEmerging standard

2.2 GB 18613 Evolution: YE2's Regulatory Context

Standard VersionEffective DateMinimum RequirementYE2 Compliance Status
GB 18613-20062008EFF2 (approx. IE1)Not applicable
GB 18613-20122012–2021.5.31Grade 3 = IE2Fully compliant
GB 18613-20202021.6.1 onwardsGrade 3 = IE3Non-compliant for new domestic sales

2.3 Global MEPS Comparison (IE2 Relevance)

Region / CountryRegulationIE2 StatusImplementation Date
European UnionEU 2019/1781Allowed only with VFD2021
ChinaGB 18613-2020Phased out for new sales2021.6.1
USADOE 10 CFR 431Equivalent to NEMA Premium2016
BrazilABNT NBR 17094Minimum (IE3 equivalent)2019
IndiaIS 12615Minimum (IE2 level)2019

3. Design Standards & Construction

3.1 Compliance Standards

StandardScopeYE2 Compliance
IEC 60034-1Rating and performanceFull compliance
IEC 60034-2-1Methods for determining lossesFull compliance (IE2 testing)
IEC 60034-5Degrees of protection (IP code)IP55 standard
IEC 60034-30-1Efficiency classesIE2 class compliance
GB 18613-2012Minimum allowable energy efficiencyGrade 3 compliance

3.2 Construction Features

ComponentSpecificationEngineering Benefit
Frame (H63–H160)Die-cast aluminum alloy (ADC12)Lightweight, excellent heat dissipation
Frame (H180–H355)Cast iron (HT250)High mechanical strength, vibration damping
Stator CoreCold-rolled silicon steel (50W470)Low core loss, high magnetic permeability
Rotor BarsHigh-conductivity aluminum die-castLow rotor resistance, high starting torque
Winding WireQZ-2/155 (Class F) enameled copperHigh thermal endurance, excellent dielectric
Insulation SystemClass F (155°C) with Class B rise25K safety margin ensures long life

3.3 Model Nomenclature System

YE2 - □□□ □ - □ - □
        │      │   │   │   └── Mounting code (B3/B5/B35/V1/etc.)
        │      │   │   └────── Pole number (2/4/6/8)
        │      │   └────────── Core length code (S/M/L/1/2)
        │      └─────────────── Frame size (center height in mm)
        └────────────────────── Series designation (Y + E2 = IE2 Efficiency)
        Example: YE2-132M-4-B3
        YE2: High-efficiency three-phase asynchronous motor (IE2 class)
        132: Center height = 132 mm
        M: Medium frame length
        4: 4-pole (1,500 r/min synchronous, ~1,440 r/min rated)
        B3: Foot-mounted, horizontal shaft

4. Technical Specifications & Performance Data

4.1 Standard Operating Conditions

ParameterSpecification
Rated Voltage380 V (3-phase), 50 Hz (standard)
Power Range0.12 kW – 315 kW (standard series)
Frame SizeH63 – H355 (IEC 60072)
Protection ClassIP55 (standard); IP54 / IP56 / IP65 (optional)
Insulation ClassClass F (155°C) with Class B (130°C) temperature rise
Cooling MethodIC411 (Totally Enclosed Fan-Cooled, TEFC)
Duty TypeS1 (Continuous Duty)
ConnectionStar (Y) for ≤ 3 kW; Delta (Δ) for ≥ 4 kW

4.2 Efficiency Data — 4-Pole (1,500 r/min synchronous)

ModelPower (kW)Speed (r/min)Efficiency (%)Power FactorCurrent (A)
YE2-801-40.551,40571.00.751.50
YE2-90S-41.11,44576.20.772.60
YE2-100L1-42.21,44081.00.814.65
YE2-112M-44.01,44084.20.827.90
YE2-132M-47.51,44087.00.8414.0
YE2-160M-4111,45088.40.8520.0
YE2-180M-418.51,45590.00.8632.5
YE2-200L-4301,46091.40.8651.5
YE2-225M-4451,46092.50.8774.5
YE2-280S-4751,47093.60.88120.0
YE2-315M-41321,47094.50.88206.0

5. Efficiency Analysis & Loss Breakdown

5.1 Motor Loss Components

The total losses in an induction motor comprise five principal components: 
Ploss = Pstator_cu + Protor_cu + Piron + Pfriction_windage + Pstray

Loss ComponentIE1 (Baseline)IE2 (YE2)IE3 (YE3)Reduction Strategy
Stator copper loss32%28%24%Increased copper cross-section
Rotor aluminum loss18%16%14%Optimized rotor slot geometry
Core (iron) loss28%25%22%Thinner laminations; higher grade steel
Friction & windage12%12%12%Optimized fan design
Stray load loss10%9%8%Improved winding distribution

5.3 IE2 vs. IE3: Upgrade Economics

Power (kW)IE2 Efficiency (%)IE3 Efficiency (%)Efficiency GainSimple Payback (years)
1.581.385.5+4.2%1.8–2.4
5.587.089.2+2.2%2.5–3.8
1189.491.2+1.8%3.0–4.5
2290.592.1+1.6%3.5–5.2
9093.994.8+0.9%5.5–8.8

6. Dimensional Data & Mounting Configurations

6.1 Foot-Mounted (B3) Dimensions (mm)

FrameABCDEHL
8012510050194080285
112M190140702860112400
132M216178893880132508
160M25421010842110160600
200L31830513355110200780
280S457368190751402801,020

6.3 Mounting Configuration Availability

CodeDescriptionH63–H112H132–H160H180–H225H250–H355
B3Foot-mounted, horizontal✓✓✓✓
B5Flange-mounted, large flange✓✓✓✓
B35Foot + large flange✓✓✓✓
V1Vertical, shaft downward✓✓✓✓

7. Torque Characteristics & Starting Performance

7.1 Torque-Speed Relationship

The electromagnetic torque of an induction motor is given by: 
T = (3p / 2πf) × (V12 × (R'2/s)) / [ (R1 + R'2/s)2 + (X1 + X'2)2 ]

Pole NumberSynchronous Speed (r/min)Typical Rated Speed (r/min)Typical Slip (%)
23,0002,890–2,9800.7–3.7
41,5001,440–1,4702.0–4.0
61,000960–9901.0–4.0
8750710–7401.3–5.3

7.2 Starting Torque Requirements by Load Type

Load TypeRequired Tst/TnYE2 SuitabilityStarting Method
Centrifugal pump1.2–1.5ExcellentDOL up to 5.5 kW
Fan (low inertia)1.3–1.8ExcellentDOL up to 11 kW
Fan (high inertia)1.8–2.5GoodStar-delta or soft starter
Conveyor (loaded)2.0–2.8MarginalHigh-torque motor or soft starter
Crane / Hoist2.5–3.5PoorHigh-slip or specialized motor

8. Application Engineering

8.1 Industry Application Matrix

Industry SectorTypical ApplicationPreferred YE2 SpecDuty Considerations
Water SupplyRaw water pumps, booster pumps4-pole, IP55, cast ironContinuous duty; possible VFD
HVACChilled water pumps, cooling towers4-pole or 6-pole, IP55Continuous duty; variable load
Food & BeverageMixers, conveyors, packaging4-pole, IP55 or IP65Washdown duty; food-grade
Mining & QuarryingCrushers, screens, conveyors4-pole, IP55, cast ironDust; vibration; heavy duty
Oil & GasPump jacks, transfer pumps4-pole, IP55 or IP56Hazardous area options

8.2 Pump Application Power Sizing

For centrifugal pump applications: 
Phydraulic = (Q × H) / 367 [kW] 
Pmotor = (Q × H) / (367 × ηp × ηm) × SF

Sizing Example: HVAC chilled water circulation pump 
Q = 80 m³/h, H = 32 m, Pump efficiency = 75% 
Pmotor = (80 × 32) / (367 × 0.75 × 0.857) × 1.10 = 11.94 kW 
Selected: YE2-160M-4 (11 kW) — slightly below calculated but within acceptable margin for pump service factor.

8.3 Variable Frequency Drive (VFD) Compatibility

ParameterYE2 with VFDNotes
Minimum speed25–30 Hz (50%–60%)Below this, motor cooling may be insufficient
Maximum speed50–55 Hz (100%–110%)Do not exceed without manufacturer approval
Recommended VFD typeScalar (V/Hz) or Sensorless VectorVector control preferred for torque-critical
Cable length< 50 m without filterLong cables cause voltage reflection
Derating5–10% below 30 HzReduced self-cooling at low speed

9. Comparative Analysis: YE2 vs. Alternative Motor Series

Evaluation CriteriaYE2 (IE2)Y3/YE3 (IE3)YX3/YE4 (IE4)Y Series (IE1)
Efficiency classIE2 (High)IE3 (Premium)IE4 (Super Premium)IE1 (Standard)
Full-load eff. (11 kW)88.4%91.2%92.5%87.6%
Purchase price index100 (baseline)110–120130–15085–90
China domestic (post-2021)RestrictedFully compliantFully compliantPhased out
Export market acceptanceGoodExcellentPremium nicheDeclining
Best applicationExport; retrofit; cost-sensitiveNew installations; high-runContinuous duty; energy-criticalNon-regulated markets only

10. Quality Assurance & Certifications

CertificationStandardYE2 Status
CCCGB standardsCertified (pre-2021)
CE MarkingEU Low Voltage DirectiveCertified
ISO 9001ISO 9001:2015Certified
IECIEC 60034 seriesCompliant
EACTR CU 004/2011Certified

11. Maintenance & Troubleshooting

11.1 Preventive Maintenance Schedule

IntervalComponentActionIndicator of Required Service
MonthlyBearing temperatureRecord readingsRising trend > 2°C/month
MonthlyVibrationMeasure and recordIncrease > 10% from baseline
QuarterlyTerminal connectionsCheck tightnessLoose, discolored, or corroded
Semi-annuallyInsulation resistanceMegger test (500V DC)< 100 MΩ
AnnuallyCoupling alignmentLaser or dial checkDeviation > 50% of spec

11.2 Common Faults & Remedies

SymptomProbable CauseDiagnostic ActionCorrective Measure
Motor overheatingOverload; low voltage; blocked coolingCheck current vs. nameplate; measure voltageReduce load; improve ventilation
Excessive vibrationUnbalance; misalignment; bearing wearBalance check; alignment; vibration spectrumRebalance; realign; replace bearings
High currentOverload; single-phasing; mechanical bindingCompare to nameplate; check phase balanceReduce load; correct supply; free binding
Noise (mechanical)Bearing failure; rubbing; loose fanVibration analysis; visual inspectionReplace bearing; correct clearance
Insulation failureMoisture; overheating; contaminationMegger test; inspect windingsDry windings; correct cause; rewind

12. Conclusion

The YE2 series high-efficiency three-phase asynchronous motor occupies a significant position in the evolution of industrial motor efficiency. As the first Chinese motor series purpose-designed to meet IE2 / GB 18613-2012 Grade 3 efficiency requirements, the YE2 established the technical and commercial foundation for subsequent IE3 and IE4 developments.

For procurement professionals and system designers, the YE2 series offers proven efficiency (20% lower losses than IE1), global interchangeability, regulatory flexibility for export markets, and cost-effectiveness for moderate-run applications.

However, the regulatory landscape has shifted decisively toward IE3 as the new baseline. For new installations in regulated markets, YE3 (IE3) or higher should be specified. The YE2 series is best reserved for export markets where IE2 remains the accepted standard, replacement applications where upgrading to IE3 is not economically justified, and cost-sensitive projects with low operating hours.

Get Expert Support for YE2 Motor Selection

Choose TITECHO's YE2 series for proven reliability, global interchangeability, and cost-effective efficiency in export and retrofit applications. Our engineering team responds within 24 hours!

📞 +86 13305761511

✉️ info@cntecho.com

💬 WhatsApp: Nancy / Jahor

Get Free Custom Quote Now → 

LATEST

INFORMATION

Get the latest product information of the company

%{tishi_zhanwei}%

CONTACT US

Telephone: +86 13305761511
Email: info@cntecho.com

Add: RM. 602, BUILDING B, NO.1551 SHUANGSHUI RD., LUQIAO DIST., TAIZHOU CITY, ZHEJIANG, CHINA

 


Copyright © 2026 TECHO ELECTRICAL & MECHANICAL (TAIZHOU) CO., LTD. All Rights Reserved.

Business License

Search for the product name you want to search

TECHO ELECTRICAL & MECHANICAL

%{tishi_zhanwei}%