Jul 03,2026
YE2 High‑Efficiency Motor Overview
An in‑depth overview of YE2 high‑efficiency motors, including IE2 efficiency classification, regulatory background, performance tables, and engineering design features.
1. Introduction
The YE2 series high-efficiency three-phase asynchronous motor represents a pivotal milestone in China's industrial motor evolution — bridging the gap between legacy standard-efficiency designs and modern premium-efficiency requirements. Developed in response to GB 18613-2012 (China's mandatory motor energy efficiency standard) and harmonized with IEC 60034-30-1 IE2 international efficiency classification, the YE2 series established the foundation for energy-conscious motor design in the Chinese manufacturing sector.
While subsequent regulatory updates (notably GB 18613-2020, effective June 1, 2021) have elevated the minimum efficiency requirement from IE2 to IE3 for most general-purpose motors, the YE2 series remains extensively deployed across existing industrial infrastructure, export markets with IE2 acceptance, and applications where IE2 represents the optimal balance of efficiency and capital cost. Understanding the YE2 series is therefore essential for maintenance engineers, procurement professionals, and system designers operating across diverse regulatory environments.
2. Regulatory Framework & Efficiency Classification
2.1 IEC 60034-30-1 Efficiency Classes
| Efficiency Class | Designation | Typical Full-Load Efficiency | Loss Reduction vs. IE1 | Regulatory Status |
|---|---|---|---|---|
| IE1 | Standard Efficiency | 91.7% | Baseline | Phased out in EU, China |
| IE2 | High Efficiency | 93.2% | ~20% lower | Mandatory in some regions |
| IE3 | Premium Efficiency | 94.5% | ~35% lower | Mandatory in EU, China |
| IE4 | Super Premium | 95.6% | ~50% lower | Voluntary premium |
| IE5 | Ultra-Premium | 96.7% | ~60% lower | Emerging standard |
2.2 GB 18613 Evolution: YE2's Regulatory Context
| Standard Version | Effective Date | Minimum Requirement | YE2 Compliance Status |
|---|---|---|---|
| GB 18613-2006 | 2008 | EFF2 (approx. IE1) | Not applicable |
| GB 18613-2012 | 2012–2021.5.31 | Grade 3 = IE2 | Fully compliant |
| GB 18613-2020 | 2021.6.1 onwards | Grade 3 = IE3 | Non-compliant for new domestic sales |
2.3 Global MEPS Comparison (IE2 Relevance)
| Region / Country | Regulation | IE2 Status | Implementation Date |
|---|---|---|---|
| European Union | EU 2019/1781 | Allowed only with VFD | 2021 |
| China | GB 18613-2020 | Phased out for new sales | 2021.6.1 |
| USA | DOE 10 CFR 431 | Equivalent to NEMA Premium | 2016 |
| Brazil | ABNT NBR 17094 | Minimum (IE3 equivalent) | 2019 |
| India | IS 12615 | Minimum (IE2 level) | 2019 |
3. Design Standards & Construction
3.1 Compliance Standards
| Standard | Scope | YE2 Compliance |
|---|---|---|
| IEC 60034-1 | Rating and performance | Full compliance |
| IEC 60034-2-1 | Methods for determining losses | Full compliance (IE2 testing) |
| IEC 60034-5 | Degrees of protection (IP code) | IP55 standard |
| IEC 60034-30-1 | Efficiency classes | IE2 class compliance |
| GB 18613-2012 | Minimum allowable energy efficiency | Grade 3 compliance |
3.2 Construction Features
| Component | Specification | Engineering Benefit |
|---|---|---|
| Frame (H63–H160) | Die-cast aluminum alloy (ADC12) | Lightweight, excellent heat dissipation |
| Frame (H180–H355) | Cast iron (HT250) | High mechanical strength, vibration damping |
| Stator Core | Cold-rolled silicon steel (50W470) | Low core loss, high magnetic permeability |
| Rotor Bars | High-conductivity aluminum die-cast | Low rotor resistance, high starting torque |
| Winding Wire | QZ-2/155 (Class F) enameled copper | High thermal endurance, excellent dielectric |
| Insulation System | Class F (155°C) with Class B rise | 25K safety margin ensures long life |
3.3 Model Nomenclature System
YE2 - □□□ □ - □ - □
│ │ │ │ └── Mounting code (B3/B5/B35/V1/etc.)
│ │ │ └────── Pole number (2/4/6/8)
│ │ └────────── Core length code (S/M/L/1/2)
│ └─────────────── Frame size (center height in mm)
└────────────────────── Series designation (Y + E2 = IE2 Efficiency)
Example: YE2-132M-4-B3
YE2: High-efficiency three-phase asynchronous motor (IE2 class)
132: Center height = 132 mm
M: Medium frame length
4: 4-pole (1,500 r/min synchronous, ~1,440 r/min rated)
B3: Foot-mounted, horizontal shaft4. Technical Specifications & Performance Data
4.1 Standard Operating Conditions
| Parameter | Specification |
|---|---|
| Rated Voltage | 380 V (3-phase), 50 Hz (standard) |
| Power Range | 0.12 kW – 315 kW (standard series) |
| Frame Size | H63 – H355 (IEC 60072) |
| Protection Class | IP55 (standard); IP54 / IP56 / IP65 (optional) |
| Insulation Class | Class F (155°C) with Class B (130°C) temperature rise |
| Cooling Method | IC411 (Totally Enclosed Fan-Cooled, TEFC) |
| Duty Type | S1 (Continuous Duty) |
| Connection | Star (Y) for ≤ 3 kW; Delta (Δ) for ≥ 4 kW |
4.2 Efficiency Data — 4-Pole (1,500 r/min synchronous)
| Model | Power (kW) | Speed (r/min) | Efficiency (%) | Power Factor | Current (A) |
|---|---|---|---|---|---|
| YE2-801-4 | 0.55 | 1,405 | 71.0 | 0.75 | 1.50 |
| YE2-90S-4 | 1.1 | 1,445 | 76.2 | 0.77 | 2.60 |
| YE2-100L1-4 | 2.2 | 1,440 | 81.0 | 0.81 | 4.65 |
| YE2-112M-4 | 4.0 | 1,440 | 84.2 | 0.82 | 7.90 |
| YE2-132M-4 | 7.5 | 1,440 | 87.0 | 0.84 | 14.0 |
| YE2-160M-4 | 11 | 1,450 | 88.4 | 0.85 | 20.0 |
| YE2-180M-4 | 18.5 | 1,455 | 90.0 | 0.86 | 32.5 |
| YE2-200L-4 | 30 | 1,460 | 91.4 | 0.86 | 51.5 |
| YE2-225M-4 | 45 | 1,460 | 92.5 | 0.87 | 74.5 |
| YE2-280S-4 | 75 | 1,470 | 93.6 | 0.88 | 120.0 |
| YE2-315M-4 | 132 | 1,470 | 94.5 | 0.88 | 206.0 |
5. Efficiency Analysis & Loss Breakdown
5.1 Motor Loss Components
The total losses in an induction motor comprise five principal components:
Ploss = Pstator_cu + Protor_cu + Piron + Pfriction_windage + Pstray
| Loss Component | IE1 (Baseline) | IE2 (YE2) | IE3 (YE3) | Reduction Strategy |
|---|---|---|---|---|
| Stator copper loss | 32% | 28% | 24% | Increased copper cross-section |
| Rotor aluminum loss | 18% | 16% | 14% | Optimized rotor slot geometry |
| Core (iron) loss | 28% | 25% | 22% | Thinner laminations; higher grade steel |
| Friction & windage | 12% | 12% | 12% | Optimized fan design |
| Stray load loss | 10% | 9% | 8% | Improved winding distribution |
5.3 IE2 vs. IE3: Upgrade Economics
| Power (kW) | IE2 Efficiency (%) | IE3 Efficiency (%) | Efficiency Gain | Simple Payback (years) |
|---|---|---|---|---|
| 1.5 | 81.3 | 85.5 | +4.2% | 1.8–2.4 |
| 5.5 | 87.0 | 89.2 | +2.2% | 2.5–3.8 |
| 11 | 89.4 | 91.2 | +1.8% | 3.0–4.5 |
| 22 | 90.5 | 92.1 | +1.6% | 3.5–5.2 |
| 90 | 93.9 | 94.8 | +0.9% | 5.5–8.8 |
6. Dimensional Data & Mounting Configurations
6.1 Foot-Mounted (B3) Dimensions (mm)
| Frame | A | B | C | D | E | H | L |
|---|---|---|---|---|---|---|---|
| 80 | 125 | 100 | 50 | 19 | 40 | 80 | 285 |
| 112M | 190 | 140 | 70 | 28 | 60 | 112 | 400 |
| 132M | 216 | 178 | 89 | 38 | 80 | 132 | 508 |
| 160M | 254 | 210 | 108 | 42 | 110 | 160 | 600 |
| 200L | 318 | 305 | 133 | 55 | 110 | 200 | 780 |
| 280S | 457 | 368 | 190 | 75 | 140 | 280 | 1,020 |
6.3 Mounting Configuration Availability
| Code | Description | H63–H112 | H132–H160 | H180–H225 | H250–H355 |
|---|---|---|---|---|---|
| B3 | Foot-mounted, horizontal | ✓ | ✓ | ✓ | ✓ |
| B5 | Flange-mounted, large flange | ✓ | ✓ | ✓ | ✓ |
| B35 | Foot + large flange | ✓ | ✓ | ✓ | ✓ |
| V1 | Vertical, shaft downward | ✓ | ✓ | ✓ | ✓ |
7. Torque Characteristics & Starting Performance
7.1 Torque-Speed Relationship
The electromagnetic torque of an induction motor is given by:
T = (3p / 2πf) × (V12 × (R'2/s)) / [ (R1 + R'2/s)2 + (X1 + X'2)2 ]
| Pole Number | Synchronous Speed (r/min) | Typical Rated Speed (r/min) | Typical Slip (%) |
|---|---|---|---|
| 2 | 3,000 | 2,890–2,980 | 0.7–3.7 |
| 4 | 1,500 | 1,440–1,470 | 2.0–4.0 |
| 6 | 1,000 | 960–990 | 1.0–4.0 |
| 8 | 750 | 710–740 | 1.3–5.3 |
7.2 Starting Torque Requirements by Load Type
| Load Type | Required Tst/Tn | YE2 Suitability | Starting Method |
|---|---|---|---|
| Centrifugal pump | 1.2–1.5 | Excellent | DOL up to 5.5 kW |
| Fan (low inertia) | 1.3–1.8 | Excellent | DOL up to 11 kW |
| Fan (high inertia) | 1.8–2.5 | Good | Star-delta or soft starter |
| Conveyor (loaded) | 2.0–2.8 | Marginal | High-torque motor or soft starter |
| Crane / Hoist | 2.5–3.5 | Poor | High-slip or specialized motor |
8. Application Engineering
8.1 Industry Application Matrix
| Industry Sector | Typical Application | Preferred YE2 Spec | Duty Considerations |
|---|---|---|---|
| Water Supply | Raw water pumps, booster pumps | 4-pole, IP55, cast iron | Continuous duty; possible VFD |
| HVAC | Chilled water pumps, cooling towers | 4-pole or 6-pole, IP55 | Continuous duty; variable load |
| Food & Beverage | Mixers, conveyors, packaging | 4-pole, IP55 or IP65 | Washdown duty; food-grade |
| Mining & Quarrying | Crushers, screens, conveyors | 4-pole, IP55, cast iron | Dust; vibration; heavy duty |
| Oil & Gas | Pump jacks, transfer pumps | 4-pole, IP55 or IP56 | Hazardous area options |
8.2 Pump Application Power Sizing
For centrifugal pump applications:
Phydraulic = (Q × H) / 367 [kW]
Pmotor = (Q × H) / (367 × ηp × ηm) × SF
Sizing Example: HVAC chilled water circulation pump
Q = 80 m³/h, H = 32 m, Pump efficiency = 75%
Pmotor = (80 × 32) / (367 × 0.75 × 0.857) × 1.10 = 11.94 kW
Selected: YE2-160M-4 (11 kW) — slightly below calculated but within acceptable margin for pump service factor.
8.3 Variable Frequency Drive (VFD) Compatibility
| Parameter | YE2 with VFD | Notes |
|---|---|---|
| Minimum speed | 25–30 Hz (50%–60%) | Below this, motor cooling may be insufficient |
| Maximum speed | 50–55 Hz (100%–110%) | Do not exceed without manufacturer approval |
| Recommended VFD type | Scalar (V/Hz) or Sensorless Vector | Vector control preferred for torque-critical |
| Cable length | < 50 m without filter | Long cables cause voltage reflection |
| Derating | 5–10% below 30 Hz | Reduced self-cooling at low speed |
9. Comparative Analysis: YE2 vs. Alternative Motor Series
| Evaluation Criteria | YE2 (IE2) | Y3/YE3 (IE3) | YX3/YE4 (IE4) | Y Series (IE1) |
|---|---|---|---|---|
| Efficiency class | IE2 (High) | IE3 (Premium) | IE4 (Super Premium) | IE1 (Standard) |
| Full-load eff. (11 kW) | 88.4% | 91.2% | 92.5% | 87.6% |
| Purchase price index | 100 (baseline) | 110–120 | 130–150 | 85–90 |
| China domestic (post-2021) | Restricted | Fully compliant | Fully compliant | Phased out |
| Export market acceptance | Good | Excellent | Premium niche | Declining |
| Best application | Export; retrofit; cost-sensitive | New installations; high-run | Continuous duty; energy-critical | Non-regulated markets only |
10. Quality Assurance & Certifications
| Certification | Standard | YE2 Status |
|---|---|---|
| CCC | GB standards | Certified (pre-2021) |
| CE Marking | EU Low Voltage Directive | Certified |
| ISO 9001 | ISO 9001:2015 | Certified |
| IEC | IEC 60034 series | Compliant |
| EAC | TR CU 004/2011 | Certified |
11. Maintenance & Troubleshooting
11.1 Preventive Maintenance Schedule
| Interval | Component | Action | Indicator of Required Service |
|---|---|---|---|
| Monthly | Bearing temperature | Record readings | Rising trend > 2°C/month |
| Monthly | Vibration | Measure and record | Increase > 10% from baseline |
| Quarterly | Terminal connections | Check tightness | Loose, discolored, or corroded |
| Semi-annually | Insulation resistance | Megger test (500V DC) | < 100 MΩ |
| Annually | Coupling alignment | Laser or dial check | Deviation > 50% of spec |
11.2 Common Faults & Remedies
| Symptom | Probable Cause | Diagnostic Action | Corrective Measure |
|---|---|---|---|
| Motor overheating | Overload; low voltage; blocked cooling | Check current vs. nameplate; measure voltage | Reduce load; improve ventilation |
| Excessive vibration | Unbalance; misalignment; bearing wear | Balance check; alignment; vibration spectrum | Rebalance; realign; replace bearings |
| High current | Overload; single-phasing; mechanical binding | Compare to nameplate; check phase balance | Reduce load; correct supply; free binding |
| Noise (mechanical) | Bearing failure; rubbing; loose fan | Vibration analysis; visual inspection | Replace bearing; correct clearance |
| Insulation failure | Moisture; overheating; contamination | Megger test; inspect windings | Dry windings; correct cause; rewind |
12. Conclusion
The YE2 series high-efficiency three-phase asynchronous motor occupies a significant position in the evolution of industrial motor efficiency. As the first Chinese motor series purpose-designed to meet IE2 / GB 18613-2012 Grade 3 efficiency requirements, the YE2 established the technical and commercial foundation for subsequent IE3 and IE4 developments.
For procurement professionals and system designers, the YE2 series offers proven efficiency (20% lower losses than IE1), global interchangeability, regulatory flexibility for export markets, and cost-effectiveness for moderate-run applications.
However, the regulatory landscape has shifted decisively toward IE3 as the new baseline. For new installations in regulated markets, YE3 (IE3) or higher should be specified. The YE2 series is best reserved for export markets where IE2 remains the accepted standard, replacement applications where upgrading to IE3 is not economically justified, and cost-sensitive projects with low operating hours.
Get Expert Support for YE2 Motor Selection
Choose TITECHO's YE2 series for proven reliability, global interchangeability, and cost-effective efficiency in export and retrofit applications. Our engineering team responds within 24 hours!
📞 +86 13305761511
✉️ info@cntecho.com
💬 WhatsApp: Nancy / Jahor
Related News
LATEST
INFORMATION
Get the latest product information of the company
NAVIGATION
PRODUCTS
CONTACT US
Telephone: +86 13305761511
Email: info@cntecho.com
Add: RM. 602, BUILDING B, NO.1551 SHUANGSHUI RD., LUQIAO DIST., TAIZHOU CITY, ZHEJIANG, CHINA
Copyright © 2026 TECHO ELECTRICAL & MECHANICAL (TAIZHOU) CO., LTD. All Rights Reserved.