Well Pumps – Groundwater Hydraulics, TDH, Submersible & Turbine Design
A complete engineering guide to well pumps, covering aquifer hydraulics, drawdown, TDH calculation, submersible and turbine pump selection, cable sizing, screen design, installation, and long‑term maintenance.
1. Introduction: Groundwater as a Strategic Resource
Groundwater supplies approximately 40% of global irrigation and serves as the primary drinking water source for over 2 billion people. Extracting this resource reliably, efficiently, and sustainably requires well pumps engineered to operate in some of the most challenging conditions in fluid handling: submerged in corrosive water, suspended hundreds of meters below ground, and dependent on aquifer behavior that varies with season, climate, and pumping history.
Unlike surface pumps that are accessible for maintenance, well pumps — particularly submersible units — must operate for years without intervention. A single failure requires pulling the entire pump-motor-cable assembly from the well, often at significant cost and operational disruption. This article provides a comprehensive engineering guide to well pump selection, aquifer hydraulics, installation design, and long-term performance optimization.
2. Well Hydraulics: Understanding the Aquifer
2.1 Aquifer Properties
Before selecting a pump, the aquifer's hydraulic characteristics must be quantified:
| Parameter | Symbol | Unit | Definition | Typical Range |
|---|---|---|---|---|
| Transmissivity | T | m²/day | Rate of water transmission through aquifer thickness | 10–10,000 |
| Hydraulic conductivity | K | m/day | Permeability of aquifer material | 0.1–1,000 |
| Storativity | S | dimensionless | Volume of water released per unit area per unit head decline | 10⁻⁵–10⁻¹ |
| Specific capacity | Sc | m²/day | Well yield per unit drawdown | 10–5,000 |
| Static water level | SWL | m bgl | Water level before pumping begins | 0–200 |
Transmissivity from aquifer properties:
T = K · b
Where b = saturated aquifer thickness (m)
2.2 Theis Equation for Transient Drawdown
The fundamental equation governing well hydraulics in confined aquifers:
s(r,t) = (Q / 4πT) · W(u)
Where:
- s = Drawdown at distance r from well (m)
- Q = Pumping rate (m³/day)
- T = Transmissivity (m²/day)
- W(u) = Well function (exponential integral)
- u = (r²S) / (4Tt)
For small u (u < 0.01), the Cooper-Jacob approximation applies:
s = (2.3Q / 4πT) · log(2.25Tt / r²S)
Key insight: Drawdown increases linearly with pumping rate but logarithmically with time. Doubling the pumping rate doubles the drawdown; pumping for 10× longer only increases drawdown by a factor of 2.3.

2.3 Specific Capacity and Well Efficiency
Specific capacity is the most practical metric for well performance:
Sc = Q / sw
Where sw = drawdown in the pumping well (m)
Well efficiency compares actual specific capacity to theoretical:
ηwell = (Sc,actual / Sc,theoretical) × 100%
| Well Efficiency | Assessment | Action |
|---|---|---|
| > 80% | Excellent | Maintain current operation |
| 60–80% | Good | Monitor for decline |
| 40–60% | Fair | Investigate screen/formation damage |
| < 40% | Poor | Rehabilitation or redevelopment required |
2.4 Sustainable Yield
The maximum pumping rate that does not cause long-term aquifer depletion:
Qsustainable = (A · R · fsafe) / toperating
Where:
- A = Recharge area (m²)
- R = Annual recharge rate (m/year)
- fsafe = Safety factor (typically 0.5–0.7)
- toperating = Annual operating hours
Critical rule: Pumping at rates exceeding Qsustainable causes progressive water table decline, increased energy costs, and eventual well failure.
3. Total Dynamic Head (TDH) for Well Pumps
3.1 Complete TDH Equation
Total Dynamic Head for a well pump includes all elevation, pressure, and friction components:
TDH = Helevation + Hpressure + Hfriction - Hsuction
For submersible pumps (where the pump is below water level):
TDH = Hdischarge + Hpressure + Hfriction
Where:
- Hdischarge = Vertical distance from wellhead to discharge point (m)
- Hpressure = Required pressure at discharge, converted to head (m)
- Hfriction = Pipe friction losses (m)
3.2 Pump Setting Depth
The pump must be set deep enough to remain submerged during maximum drawdown:
Dsetting = Dstatic + smax + Hsubmergence + Hsafety
Where:
- Dstatic = Depth to static water level (m)
- smax = Maximum expected drawdown (m)
- Hsubmergence = Required submergence above pump intake (typically 1–3 m)
- Hsafety = Safety margin for seasonal decline (typically 2–5 m)
| Well Type | Typical Pump Setting Below Dynamic Water Level |
|---|---|
| Shallow well (<30 m) | 3–5 m |
| Deep well (30–100 m) | 5–10 m |
| Very deep well (>100 m) | 10–20 m |
| Artesian well | At or below aquifer top |
3.3 Friction Head Loss
Darcy-Weisbach equation for pipe friction:
Hf = f · (L/D) · (v²/2g)
For practical well pump design, the Hazen-Williams equation is commonly used for discharge pipes:
Hf = 10.67 · (L · Q1.852) / (C1.852 · D4.8704)
Where:
- L = Pipe length (m)
- Q = Flow rate (m³/s)
- C = Hazen-Williams coefficient (140–150 for PVC/PE, 120 for steel)
- D = Internal pipe diameter (m)
Rising main velocity limits:
| Pipe Diameter | Recommended Velocity | Maximum Velocity |
|---|---|---|
| < 50 mm | 0.8–1.2 m/s | 2.0 m/s |
| 50–100 mm | 1.0–1.5 m/s | 2.5 m/s |
| 100–200 mm | 1.2–2.0 m/s | 3.0 m/s |
| > 200 mm | 1.5–2.5 m/s | 3.5 m/s |
Excessive velocity causes water hammer, erosion, and excessive friction losses. Insufficient velocity allows air accumulation and sediment deposition.
4. Well Pump Type Selection
4.1 Selection by Depth and Flow Rate
The water source depth and required flow rate are the primary determinants of pump type:

4.2 Pump Type Characteristics
| Pump Type | Max Depth | Max Flow | Efficiency | Best Application |
|---|---|---|---|---|
| Shallow well jet pump | 8–10 m | 15 m³/h | 40–55% | Domestic, small irrigation, dug wells |
| Deep well jet pump | 30–45 m | 10 m³/h | 30–45% | Medium-depth domestic, limited flow |
| 4" submersible | 150–200 m | 25 m³/h | 55–70% | Domestic, small commercial, 4" wells |
| 6" submersible | 300–400 m | 80 m³/h | 65–78% | Commercial, agricultural, municipal |
| 8" submersible | 500–600 m | 200 m³/h | 70–82% | Large municipal, industrial, irrigation |
| 10–12" submersible | 700 m+ | 500 m³/h | 72–85% | Very large municipal, mine dewatering |
| Vertical turbine (line shaft) | 100–300 m | 5,000 m³/h | 75–88% | Large capacity, accessible for maintenance |
| Vertical turbine (submersible motor) | 300 m+ | 5,000 m³/h | 70–82% | Very deep, large capacity |
| Helical rotor (PC pump) | 200 m | 20 m³/h | 50–65% | High-viscosity water, variable speed, sand |
4.3 Jet Pump Hydraulics
Jet pumps use a venturi principle to multiply suction lift:
Htotal = Hsuction · M + Hdischarge
Where M = jet multiplier (typically 3–5 for shallow well, 1.5–2.5 for deep well)
Efficiency penalty: Jet pumps consume 30–50% more energy than submersible pumps for equivalent duty due to recirculation losses. They are generally suitable only for:
- Wells < 45 m deep
- Flow rates < 10 m³/h
- Temporary or portable installations
- Locations where submersible installation is impractical
5. Submersible Pump Design
5.1 Pump Construction
Submersible pumps consist of two main assemblies:
| Component | Function | Material Options |
|---|---|---|
| Pump end (bowl assembly) | Multi-stage centrifugal impellers develop head | Cast iron, 304 SS, 316 SS, duplex SS |
| Motor | Hermetically sealed, oil-filled or water-filled | Cast iron, 304 SS, 316 SS |
| Shaft | Transmits torque from motor to impellers | 416 SS, 17-4PH, Inconel |
| Bearings | Radial and thrust support | Ceramic, tungsten carbide, rubber |
| Mechanical seal | Isolates motor from pumped fluid | SiC/SiC, carbon/ceramic |
| Cable | Power transmission to motor | PVC, PE, EPR insulated |
5.2 Stage Count and Head Development
Each impeller stage develops a discrete head increment:
Htotal = nstages · Hstage
Where:
- Hstage = Head per stage at operating flow rate (m)
- nstages = Number of impeller stages
Typical stage heads at BEP:
| Impeller Type | Stage Head at BEP | Application |
|---|---|---|
| Radial flow (low ns) | 8–15 m | High head, low flow |
| Mixed flow (medium ns) | 5–10 m | Medium head, medium flow |
| Semi-axial (high ns) | 3–7 m | Low head, high flow |
Example: A 6" submersible pump with 20 stages, each developing 10 m at the operating flow rate:
Htotal = 20 × 10 = 200 m
5.3 Motor Cooling Requirements
Submersible motors rely on water flow past the motor housing for cooling:

Minimum flow velocity:
vmin = 0.08 + 0.0005 × Pmotor (m/s)
Where Pmotor = motor power (kW)
Consequences of insufficient cooling:
- Motor temperature rise above insulation class limit
- Reduced motor life (Arrhenius rule: life halves per 10°C increase)
- Thermal protection trip-out
- Winding insulation failure
5.4 Cable Sizing
Submersible pump cables must be sized for voltage drop and ampacity:
Voltage drop:
ΔV = I · Rcable · L · √3
For three-phase motors:
ΔV% = (√3 · I · L · (Rcosϕ + Xsinϕ) / Vline) × 100
Design limits:
- Maximum voltage drop: 5% of rated voltage
- Maximum cable temperature: 75°C (PVC), 90°C (XLPE/EPR)
| Motor Power | Current (400V, 3ph) | Max Depth (4 mm²) | Max Depth (10 mm²) | Max Depth (25 mm²) |
|---|---|---|---|---|
| 1.5 kW | 2.9 A | 150 m | 400 m | 800 m |
| 5.5 kW | 10.4 A | 40 m | 110 m | 220 m |
| 11 kW | 20.8 A | — | 55 m | 110 m |
| 22 kW | 41.6 A | — | 28 m | 55 m |
| 55 kW | 104 A | — | — | 22 m |
6. Well Screen and Filter Design
6.1 Screen Selection Criteria
The well screen is the critical interface between the aquifer and the pump:
| Screen Type | Slot Size Range | Application | Cost |
|---|---|---|---|
| Slotted PVC | 0.5–3 mm | Fine to medium sand, shallow wells | Low |
| Continuous slot (Johnson) | 0.1–3 mm | All sand/gravel aquifers | Medium |
| Wire-wound stainless steel | 0.1–10 mm | Medium to coarse gravel, corrosive water | High |
| Pre-packed screen | 0.2–1 mm | Fine sand, artificial filter pack | Very High |
| Open hole (rock) | N/A | Fractured bedrock, karst limestone | N/A |
6.2 Entrance Velocity Limit
Screen entrance velocity controls sand production and screen erosion:
ventrance = Q / Aopen
Where Aopen = total open area of screen (m²)
| Aquifer Material | Max Entrance Velocity |
|---|---|
| Fine sand | 0.03 m/s |
| Medium sand | 0.04 m/s |
| Coarse sand | 0.05 m/s |
| Gravel | 0.06 m/s |
| Fractured rock | 0.08 m/s |
Design rule: Select screen length to achieve entrance velocity below the aquifer-specific limit. Insufficient screen area causes:
- Excessive drawdown
- Sand pumping
- Screen erosion and failure
- Reduced well efficiency
6.3 Filter Pack Design
For naturally unstable formations, an artificial gravel pack stabilizes the aquifer:
D50,pack = (4 ~ 6) × D50,aquifer
Where D50 = median grain size
Pack thickness: 100–200 mm annular thickness around the screen
7. Installation and Commissioning
7.1 Installation Procedure
| Step | Action | Critical Check |
|---|---|---|
| 1 | Verify well diameter, depth, and water quality | Screen integrity, sediment level |
| 2 | Measure static water level and specific capacity | Baseline performance data |
| 3 | Select pump setting depth | Submergence > minimum requirement |
| 4 | Assemble pump, motor, and cable | Alignment, torque settings, cable seals |
| 5 | Lower assembly using proper clamps/cable guides | No cable damage, no sharp bends |
| 6 | Install check valve 5–10 m above pump | Prevents backspin and water hammer |
| 7 | Connect discharge piping | Pressure test for leaks |
| 8 | Wire motor to control panel | Phase rotation, voltage, overload settings |
| 9 | Start pump, measure performance | Flow, pressure, current, vibration |
| 10 | Record baseline data | Performance curve, water level, power |
7.2 Control Panel Requirements
| Feature | Function | Specification |
|---|---|---|
| Motor starter | Soft start or DOL | Match motor FLA |
| Overload protection | Prevent motor burnout | 115% of FLA |
| Underload protection | Detect dry running or broken shaft | 80% of normal current |
| Phase failure relay | Prevent single-phasing damage | All three phases monitored |
| Level controls | Prevent dry running | Float switch, pressure transducer, or probe |
| Hour meter | Maintenance scheduling | Non-resettable |
7.3 Step-Drawdown Test
Before finalizing pump selection, a step-drawdown test determines well performance:
| Step | Duration | Pumping Rate | Measurement |
|---|---|---|---|
| 1 | 60–120 min | 0.5 × Qestimated | Water level every 15 min |
| 2 | 60–120 min | 0.75 × Qestimated | Water level every 15 min |
| 3 | 60–120 min | 1.0 × Qestimated | Water level every 15 min |
| 4 | 60–120 min | 1.25 × Qestimated | Water level every 15 min |
| Recovery | Until SWL restored | Pump off | Water level every 15 min |
Analysis: Plot sw/Q vs. Q to identify well losses (turbulent) and aquifer losses (linear). Excessive well losses indicate screen blockage or poor well development.
8. Maintenance and Troubleshooting
8.1 Predictive Maintenance Schedule
| Interval | Inspection | Indicator of Problem |
|---|---|---|
| Monthly | Current draw, discharge pressure | Current increase = wear or blockage |
| Quarterly | Water quality (sand, turbidity) | Sand = screen failure or insufficient submergence |
| Annually | Flow test vs. baseline | >10% decline = rehabilitation needed |
| 3–5 years | Downhole camera inspection | Screen corrosion, biofouling, sediment |
| 5–10 years | Pull pump for overhaul | Bearing wear, impeller erosion, seal condition |
8.2 Common Failure Modes
| Symptom | Probable Cause | Diagnostic Action | Corrective Measure |
|---|---|---|---|
| No water / low flow | Pump off-depth, drawdown exceeds setting, screen blockage | Sounding, camera inspection | Lower pump, clean/redevelop well |
| Reduced pressure / flow | Worn impellers, increased clearances, partial blockage | Compare to baseline curve | Pull pump, replace wear parts |
| High current draw | Mechanical binding, sand locking, incorrect voltage | Vibration analysis, electrical test | Pull pump, inspect bearings/impellers |
| Low current / underload | Broken shaft, dry running, check valve failure | Current signature, pressure check | Replace shaft, verify level controls |
| Motor overheating | Insufficient cooling flow, high ambient temperature, overload | Temperature monitoring, flow verification | Increase submergence, verify screen |
| Sand in discharge | Screen failure, inadequate filter pack, excessive entrance velocity | Grain size analysis, camera | Replace screen, add gravel pack |
8.3 Well Rehabilitation
When specific capacity declines >25% from baseline:
| Method | Application | Expected Recovery |
|---|---|---|
| Surge block / jetting | Screen blockage, sediment fill | 20–40% |
| Acidization (HCl) | Carbonate scale, iron oxide | 30–60% |
| Polyphosphate treatment | Clay swelling, fine particle migration | 20–40% |
| Chlorination | Biofouling, iron bacteria | 30–50% |
| Physical brushing | Hard scale, corrosion deposits | 40–70% |
9. Standards and Specifications
| Standard | Scope | Application |
|---|---|---|
| API RP 11S4 | Electric submersible pump installations | Oil & gas artificial lift |
| ANSI/HI 14.6 | Rotodynamic pumps for hydraulic performance acceptance tests | All centrifugal well pumps |
| IEC 60034-1 | Rotating electrical machines — rating and performance | Submersible motors |
| NEMA MG-1 | Motors and generators | North American motor specifications |
| ISO 10816-7 | Mechanical vibration — industrial pumps | Vibration acceptance criteria |
| AWWA E101 | Vertical turbine pumps | Municipal water supply |
| ASTM A53/A106 | Pipe specifications | Rising main and discharge piping |
10. Conclusion
Well pump engineering sits at the intersection of hydrogeology, mechanical design, and electrical engineering. A successful installation requires understanding not just the pump's performance curve, but the aquifer's response to pumping, the well's construction quality, and the long-term operational environment.
Key takeaways:
- Know your aquifer — transmissivity, storativity, and specific capacity determine sustainable yield and pump setting depth.
- TDH is everything — accurate calculation of elevation, pressure, and friction head prevents under- or over-sizing.
- Submersible pumps dominate deep wells — their efficiency, reliability, and depth capability make them the default choice for most applications.
- Motor cooling and cable sizing are critical for deep installations — voltage drop and thermal management determine motor life.
- Well screen design controls sand production and well efficiency — entrance velocity and filter pack selection are as important as pump selection.
- Baseline testing enables predictive maintenance — step-drawdown tests and performance monitoring catch problems before they become failures.
A well-designed well pump system, properly matched to the aquifer and application, can operate reliably for 15–25 years with minimal intervention. The cost of thorough upfront engineering is always less than the cost of premature failure.
References & Further Reading
- Theis, C.V. (1935). "The Relation Between the Lowering of the Piezometric Surface and the Rate and Duration of Discharge of a Well Using Ground-Water Storage." Transactions, American Geophysical Union.
- Cooper, H.H. & Jacob, C.E. (1946). "A Generalized Graphical Method for Evaluating Formation Constants and Summarizing Well-Field History." Transactions, American Geophysical Union.
- Driscoll, F.G. (2008). Groundwater and Wells, 3rd Edition. Johnson Screens.
- Roscoe Moss Company. Handbook of Ground Water Development. John Wiley & Sons.
- Grundfos. Submersible Pump Handbook. Technical Publication.
- Franklin Electric. Submersible Motor Application Manual.
- ANSI/HI 14.6-2022. Rotodynamic Pumps for Hydraulic Performance Acceptance Tests.
- AWWA E101-88 (R13). Vertical Turbine Pumps — Line Shaft and Submersible Types.
Related News
LATEST
INFORMATION
Get the latest product information of the company
NAVIGATION
PRODUCTS
CONTACT US
Telephone: +86 13305761511
Email: info@cntecho.com
Add: RM. 602, BUILDING B, NO.1551 SHUANGSHUI RD., LUQIAO DIST., TAIZHOU CITY, ZHEJIANG, CHINA
Copyright © 2026 TECHO ELECTRICAL & MECHANICAL (TAIZHOU) CO., LTD. All Rights Reserved.