TECHO ELECTRICAL & MECHANICAL

BLOG

Sep 15,2026

Reluctance Motors: SRM, SynRM, Control & Selection

Learn how reluctance motors work, including SRM and SynRM design, torque equations, control methods, selection, applications and maintenance.


1. The Fundamental Idea: Magnetic Reluctance and Rotor Alignment

Magnetic reluctance is analogous to electrical resistance: it expresses how strongly a magnetic path opposes flux. A path made of ferromagnetic steel with a small air gap has low reluctance; a path interrupted by a larger air gap or a flux barrier has higher reluctance. A salient rotor is shaped so that magnetic flux flows more easily along one rotor axis than along the perpendicular axis.

When a stator phase is energized, the rotor experiences a tendency to align its low-reluctance axis with the stator magnetic field. This geometric alignment is the source of reluctance torque. In a simple singly excited magnetic system with current held constant, electromagnetic torque can be expressed from magnetic co-energy as:

T_e=1/2i²dL(\theta)/d\theta

Where i is phase current, L(\theta) is phase inductance as a function of rotor angle \theta, and T_e is electromagnetic torque. Positive torque is produced where inductance increases with rotor angle. This equation is especially useful for understanding SRMs.

Magnetic termMeaningRelevance in reluctance-motor design
Magnetic flux \PhiMagnetic field quantity carried through the circuit.Must be controlled to avoid excessive steel saturation and loss.
Reluctance \mathcalROpposition of a magnetic path to flux.Rotor geometry intentionally varies reluctance by position.
Inductance LFlux-linkage per unit current.Changes with rotor angle; its gradient creates reluctance torque.
SaliencyDifference between magnetic properties along rotor axes.A larger useful difference between L_d and L_q increases SynRM torque potential.
Aligned positionRotor/stator teeth or low-reluctance paths aligned.Maximum phase inductance for an SRM phase; torque becomes zero at full alignment.
Unaligned positionRotor/stator teeth maximally offset.Minimum phase inductance; useful reference for phase turn-on timing.
Flux barrierAir-filled or nonmagnetic region in a SynRM rotor.Forces anisotropy by impeding cross-axis flux.

2. The Two Major Families: SRM and SynRM

Switched reluctance motors (SRMs)

An SRM has salient poles on both stator and rotor. The stator carries concentrated phase windings; the rotor is commonly a laminated steel structure with no magnets, no rotor windings, no commutator, and no cage bars. The inverter energizes phases in a carefully timed sequence. Each phase attracts the rotor toward alignment with its energized stator poles, after which the controller turns that phase off and energizes the next appropriate phase.

JMAG notes that an SRM has no magnets and no rotor windings; its article uses a common 12/8 configuration as an example [1]. Other pole combinations such as 6/4 and 8/6 are widely used. The number of stator phases and the rotor/stator pole combination influence torque ripple, switching frequency, fault tolerance, manufacturing, and control complexity.

Synchronous reluctance motors (SynRMs)

A SynRM generally uses a conventional three-phase distributed stator winding and a rotor with flux barriers or flux guides that create a strong difference between the direct-axis and quadrature-axis magnetic paths. The rotor has no windings or magnets in a pure SynRM. It runs at the synchronous speed of the rotating stator field, so it requires a controlled inverter for starting and operation.

JMAG describes the SynRM as a pure AC machine requiring sinusoidal polyphase current, usually from a current-regulated PWM inverter; synchronism is maintained by control of current phase, with a resolver, equivalent transducer, or sensorless position detection [2]. In industrial systems, SynRMs are frequently paired with dedicated VFDs and vector-control algorithms.

FeatureSwitched reluctance motor (SRM)Synchronous reluctance motor (SynRM)
Stator winding styleConcentrated, separately excited phase coilsUsually distributed three-phase AC stator winding
RotorSalient steel teeth; no magnets or windingsFlux-barrier/anisotropic laminated rotor; no magnets or windings in pure SynRM
ExcitationSequential switched phase currentSinusoidal or vector-controlled multiphase current
Typical converterIndependent asymmetric half-bridge per phase or equivalentThree-phase PWM inverter / VFD
Speed behaviorBroad controlled speed range; not inherently synchronous in the AC-machine senseRuns synchronously with commanded rotating field
Main control challengeTurn-on/turn-off angle, current profile, torque ripple, acoustic noiseRotor-angle estimation, d–q current control, flux management, power factor
Main system strengthVery robust rotor; fault-tolerant phase structure; magnet-freeHigh-efficiency industrial variable-speed drive potential; magnet-free rotor
Common challengeNoise, vibration, torque ripple, specialized converter/controlRequires inverter and benefits from accurate vector control; saliency/power-factor trade-offs

3. SRM Construction and the Switched-Phase Torque Cycle

An SRM phase winding sits on stator poles. When a particular phase is energized while the relevant rotor poles are approaching alignment, the inductance of that phase rises with rotor angle. According to T_e=1/2i²dL/d\theta, this positive inductance gradient produces positive torque. Once alignment is reached, the torque from that phase falls to zero. If current remains applied after the aligned point, dL/d\theta becomes negative and the phase can produce braking torque. The controller must therefore extinguish phase current before the rotor moves too far beyond alignment.

This timing requirement explains why the inverter and rotor-position information are fundamental parts of an SRM system. JMAG highlights that phase current must be switched off slightly before full alignment, allowing time for flux linkage to decay so negative torque is avoided [1].

SRM rotor positionInductance trend dL/d\thetaDesired phase-current actionTorque result
Fully unalignedNear zero gradientPrepare phase for energization when appropriateMinimal torque from that phase
Entering overlapPositiveTurn phase on; build currentPositive torque begins
Rising-inductance regionPositiveRegulate current to deliver target torquePositive torque production
Near alignmentGradient falling toward zeroBegin turn-off early enough for current decayTorque tapers toward zero
Beyond alignmentNegativePhase should be offEnergized phase would produce negative torque

The SRM phase-voltage equation shows why high-speed control is demanding:

v=Ri+d\lambda(i,\theta)/dt

For a simplified unsaturated form, where flux linkage \lambda=L(\theta)i:

v=Ri+Ldi/dt+iωdL/d\theta

The final term is the motion-induced voltage. As speed rises, it becomes harder to build and extinguish phase current within the available rotor-angle interval. High-speed SRM designs therefore depend on sufficient DC-bus voltage, correctly selected turn-on/turn-off angles, phase-inductance characteristics, and inverter capability.

4. SynRM Construction, Rotor Saliency, and Synchronous Torque

A SynRM rotor is designed to offer a low-reluctance path along its direct axis and a high-reluctance path along its quadrature axis. It typically uses multiple internal flux barriers formed by air regions or nonmagnetic gaps in a laminated steel rotor. The barriers make it difficult for flux to cross the q-axis while allowing flux to travel more readily along the d-axis. The difference creates magnetic saliency.

JMAG explains that in a SynRM the d-axis is the high-inductance axis and the q-axis is the low-inductance axis because q-axis flux must cross flux barriers [2]. The motor controller uses rotor-angle information to orient stator current such that the interaction with this inductance difference produces torque.

For a pure SynRM in a simplified d–q model, reluctance torque is:

T_e=3/2p(L_d-L_q)i_di_q

Where p is the number of pole pairs, L_d and L_q are d-axis and q-axis inductances, and i_d and i_q are current components in the rotor reference frame. The controller chooses the d–q current ratio to generate the required torque while managing current, voltage, losses, and power factor.

SynRM design variableEffect on performanceSelection/control implication
Saliency ratio L_d/L_qRaises potential reluctance torque when useful inductance contrast increases.Must be balanced against saturation, mechanical strength, manufacturing, and power factor.
Flux-barrier geometryShapes d- and q-axis magnetic paths.Determines torque density, ripple, loss, and rotor structural integrity.
Rotor position angleDefines d–q transformation and current-vector orientation.Requires resolver, encoder, inductive sensor, or validated sensorless estimator.
d-axis current i_dEstablishes magnetizing flux in a pure SynRM.Too little can limit torque; too much increases current and losses.
q-axis current i_qParticipates in torque production.Regulated by vector control to meet torque demand.
Inverter voltageLimits attainable flux/current at higher speed.Defines base-speed and field-weakening envelope.
Rotor mechanical designMust withstand centrifugal stress around flux barriers.High-speed designs require detailed rotor stress validation.

5. SRM and SynRM: Which Reluctance Technology Fits the Application?

The choice should not be made solely on the statement “both motors are magnet-free.” Their system behavior is different. An SRM can be attractive where rotor robustness, high-speed operation, fault tolerance, harsh environment capability, or avoidance of permanent magnets dominates. A SynRM is often attractive in industrial variable-speed applications where a conventional three-phase VFD architecture, smooth torque, and high efficiency are desired.

ABB positions synchronous reluctance technology as combining permanent-magnet-like performance potential with induction-motor simplicity and serviceability; its commercial SynRM systems are designed to pair motor and VFD as a coordinated efficiency solution [3]. The exact performance is model- and drive-dependent, so any efficiency, power-density, or lifecycle claim should be validated against the selected motor-drive combination and duty cycle.

Application requirementSRM fitSynRM fitEngineering note
Extreme rotor robustnessStrongStrongBoth have magnet- and winding-free rotors in their pure forms.
Simple standard three-phase inverterModerateStrongSynRM usually uses a conventional three-phase PWM inverter; SRM needs phase-independent switching.
High-speed capabilityStrong with appropriate designStrong with rotor stress and inverter validationEvaluate bearing, rotor, switching, and voltage limits.
Low acoustic noiseRequires careful design/controlOften easier to optimizeSRM radial-force and torque-ripple control must be addressed early.
Harsh temperature / magnet avoidanceStrongStrongCheck insulation, bearings, electronics, and rotor mechanical integrity.
Broad industrial VFD integrationMore specializedStrongSynRM drive tuning and motor data must be matched.
Fault-tolerant operationStrong due to phase separationApplication-dependentSRM phase topology can offer useful redundancy strategies.
Precise servo-like motionPossible but control-intensiveStrong with encoder/vector controlComplete control-loop design determines outcome.

6. Control Strategies and Power-Electronics Requirements

SRM converter and control

Each SRM phase must be energized and demagnetized independently. A popular arrangement uses an asymmetric bridge with two controllable switches and two diodes per phase, allowing positive voltage for current buildup and negative voltage for rapid current decay. The drive needs DC-bus management, phase-current sensing, rotor-position sensing or estimation, commutation-angle calculation, current regulation, protection, and a torque-sharing strategy.

At lower speed, current-chopping control can maintain the target current by rapidly switching the phase voltage. At higher speed, there may not be enough time for high-frequency regulation; the controller often operates in a single-pulse or angle-controlled mode. Torque sharing overlaps phase torque contributions to reduce net ripple.

SynRM vector control

SynRMs are commonly controlled with field-oriented control. The inverter measures or estimates currents, obtains rotor position, transforms phase currents into d–q components, compares them with command values, and regulates the current vector with PWM. The result can deliver smooth torque and speed control, but it relies on accurate machine parameters, position information, current sensing, inverter voltage, and thermal management.

Control topicSRM approachSynRM approach
Torque commandPhase-current reference and conduction-angle scheduled–q current references, often MTPA-/efficiency-oriented
Rotor positionEncoder/resolver/Hall-like sensing or sensorless estimationResolver, encoder, inductive sensor, or sensorless observer
Current controlPer-phase current chopping or pulse-angle controlThree-phase vector current regulation
High-speed limitationCurrent-rise/decay time within narrow conduction windowInverter voltage, flux control, switching frequency, rotor stress
Torque-ripple reductionPhase overlap and optimized current shapingSinusoidal/vector current control and parameter tuning
Core protectionPhase overcurrent, DC-bus overvoltage, loss of positionPhase overcurrent, DC-bus overvoltage, loss of position/observer lock
System commissioningInductance map, angle calibration, current limits, torque mapMotor parameter identification, angle calibration, current-loop tuning

7. Torque Ripple, Noise, and Vibration: The Key Reluctance-Motor Design Challenge

Reluctance motors can be highly robust, but they must be designed consciously for NVH—noise, vibration, and harshness. In SRMs, the pulsed torque waveform and radial magnetic forces can excite stator structural modes. The resulting acoustic output is not determined by the motor alone: the controller’s phase currents, switching frequency, turn-on/turn-off angles, torque sharing, mechanical housing, mounting, and load inertia all contribute.

SynRMs generally produce smoother torque under sinusoidal/vector control, but they are still susceptible to electromagnetic noise, inverter harmonics, mechanical resonance, and rotor/air-gap variation. Acoustic targets should be included in the motor-drive specification at the beginning, rather than treated as a final packaging problem.

NVH contributorTypical mechanismMitigation direction
SRM torque rippleIndividual phase torque pulses do not sum to perfectly constant output torque.Optimize phase overlap, current profiles, torque-sharing function, pole count, and mechanical filtering.
Radial magnetic forceAir-gap forces excite stator teeth and housing.Stiffen structure, optimize pole geometry/current waveform, avoid resonant frequencies.
PWM switchingInverter switching creates current ripple and audible components.Choose appropriate switching strategy/frequency; validate loss and EMI trade-offs.
Rotor/stator eccentricityUneven air gap amplifies electromagnetic forces.Control manufacturing tolerances, bearing fit, shaft alignment, and rotor balance.
Load resonanceCoupling, gearbox, or driven equipment resonates with torque pulsation.Perform system modal assessment; alter control bandwidth, coupling, inertia, or structural stiffness.
Flux saturationNonlinear inductance distorts force and torque waveforms.Use saturation-aware control maps and magnetic design validation.

8. Performance Curves and What to Request from a Supplier

Reluctance motors cannot be selected responsibly using only nominal power and frame size. Request curves and test data that show speed–torque capability, efficiency map, current demand, thermal limits, noise behavior where relevant, inverter compatibility, and overload envelope. For SRMs, operating performance depends heavily on the controller’s current and commutation angles. For SynRMs, performance depends on the inverter, current vector, field-weakening strategy, and rotor-position implementation.

Data to requestWhy it matters
Continuous and peak torque–speed curveSeparates thermal-safe capability from short-duration transient capability.
Efficiency map or stated operating-point efficiencyEnables real duty-cycle and energy-cost evaluation.
Phase resistance/inductance or d–q parameter dataRequired for controller matching, simulation, and loss estimation.
DC-bus voltage and inverter-current requirementsConfirms speed headroom and controller sizing.
Position-feedback requirementsDetermines encoder/resolver/sensorless architecture, startup behavior, and wiring.
Thermal model or temperature-rise dataIdentifies continuous limits at actual ambient and mounting conditions.
Noise/vibration dataEssential for appliances, occupied spaces, instruments, and precision machinery.
Rotor inertia and mechanical speed limitNeeded for acceleration, overspeed, bearing, and rotor-stress analysis.
Environmental and enclosure ratingsConfirms suitability for dust, moisture, washdown, corrosives, hazardous areas, and altitude.
Cable/EMI guidanceImportant because inverter-driven machines are system-level electromagnetic products.

9. Practical Selection Workflow

Begin with the load, then size the motor and converter as one system. A reluctance motor can be excellent when its inherent strengths match the application; it can be disappointing when the controller, NVH target, speed range, or thermal environment is treated as an afterthought.

StepWhat to determineWhy it matters
1Speed range, continuous torque, peak torque, duty cycleEstablishes the required operating envelope.
2Load inertia and required acceleration/decelerationDetermines transient torque and DC-bus energy management.
3Supply type and DC-bus constraintsDefines inverter topology, voltage headroom, protection, and regenerative path.
4Space, mass, and mounting envelopeConstrains frame, cooling, shaft, bearings, and structural resonance.
5Environmental conditionsDetermines insulation, enclosure, bearing seals, material compatibility, and derating.
6Acoustic/vibration targetOften determines whether SRM is viable or what mitigation is necessary.
7Control and feedback requirementsDefines sensorless versus sensored architecture and the needed processing/performance level.
8Efficiency and lifecycle goalsGuides SynRM versus SRM versus induction/PM alternatives on a total-system basis.
9Fault behavior and service modelEvaluates phase faults, lock-rotor protection, diagnostics, repairability, and spare strategy.
10End-product validationConfirms performance with the actual load, cable, enclosure, ambient, and supply.

Example: First-pass SRM torque calculation

Assume a phase is operating where its inductance gradient is approximately dL/d\theta=0.020\ H/rad, and the controller applies a 10 A phase current. In a simplified constant-current, unsaturated calculation:

T_e=1/2i²dL/d\theta

T_e=1/2×10²×0.020=1.0\ N·m

This is an instantaneous phase-torque estimate, not a final shaft-rating calculation. Real machines experience magnetic saturation, current rise/decay dynamics, phase overlap, torque ripple, iron loss, mechanical loss, thermal limits, and inverter constraints. The example nevertheless shows the central SRM principle: torque increases with the square of phase current and with the positive inductance gradient.

Example: SynRM synchronous speed

For a 4-pole SynRM driven at 50 Hz:

N_s=120f/P=120×50/4=1,500\ rpm

With correct inverter control, the rotor runs at the commanded synchronous speed rather than at the slightly lower speed associated with induction-motor slip. When frequency is changed by the drive, the synchronous speed changes proportionally. The inverter must manage both frequency and voltage/current to maintain appropriate flux and torque.

10. Applications: Where Reluctance Motors Add Value

Reluctance motors are not universal replacements for induction or permanent-magnet motors. They are strong candidates when robust magnet-free rotors, high-speed capability, harsh-environment tolerance, system efficiency, or supply-chain considerations are important—and when the required electronics and control sophistication fit the product.

ApplicationPromising reluctance-motor optionWhy it can fit
Variable-speed pumps and fansSynRM + matched VFDEfficient industrial variable-speed architecture with magnet-free rotor.
Compressors and HVAC equipmentSynRM or optimized SRMHigh-speed capability and system-level efficiency opportunities.
Industrial automationSynRM with vector controlSmooth controllable torque/speed using three-phase inverter architecture.
High-temperature or magnet-sensitive environmentsSRM or SynRMMagnet-free rotor avoids permanent-magnet temperature and material concerns.
Harsh-duty traction/actuation conceptsSRMRobust simple rotor and potential phase-fault strategies.
Appliances and vacuum/blower systemsOptimized SRM or SynRMMotor choice depends heavily on acoustic target and controller cost.
Pumps in chemical, water, and process industriesSynRM + VFDVariable-speed efficiency, controllability, and low-maintenance rotor design.
Specialized high-speed drivesSRM or SynRMRequires rotor stress, bearing, inverter-voltage, and NVH validation.

11. Maintenance and Troubleshooting

The absence of brushes, commutators, and rotor windings in pure SRM and SynRM designs eliminates several traditional maintenance mechanisms. However, the system still contains bearings, stator insulation, inverter semiconductors, cooling paths, current sensors, position feedback devices, connectors, and cables. Reliability depends on the complete electromechanical assembly.

SymptomPossible causesInitial investigation
SRM will not startIncorrect rotor-position reference, phase wiring error, insufficient current, locked loadVerify position-sensor alignment, phase sequence, DC bus, current limit, and rotor freedom.
SynRM loses synchronismIncorrect angle estimate, current/voltage limit, rapid load change, drive parameter errorReview drive fault log, position feedback, current loops, load transient, and motor parameters.
Excessive acoustic noisePoor timing/current profile, resonance, saturation, loose mount, PWM interactionCompare NVH versus speed/load; inspect mounting and tune current/commutation strategy.
OverheatingExcess RMS current, high ambient, weak cooling, core loss, inverter lossMeasure phase currents, stator/case temperature, controller temperature, airflow, and duty profile.
Torque shortfallUnder-voltage, current limit, incorrect parameters, saturation, load frictionVerify actual DC-bus voltage, current command, magnetic/control map, and driven-load torque.
Sensorless instabilityWeak observability at low speed, poor model parameters, EMI, abrupt load disturbanceUse validated startup logic, filter/tune estimator, inspect harness/grounding, consider feedback sensor.
Bearing failureMisalignment, contamination, overload, vibration, inadequate lubricationInspect mechanical alignment, radial/axial loads, seals, lubrication, and structural resonance.

Conclusion: Reluctance Motors Reward System-Level Engineering

Reluctance motors derive useful torque from geometry, magnetic anisotropy, and intelligently controlled current. Their rotors can be exceptionally robust because pure SRM and SynRM designs have neither permanent magnets nor rotor windings. But this mechanical simplicity is paired with an essential requirement: the inverter, rotor-position strategy, current control, thermal design, and structural NVH behavior must be engineered as one system.

Choose an SRM when its separate-phase architecture, robust rotor, broad speed potential, and magnet-free design outweigh the complexity of specialized switching and NVH optimization. Choose a SynRM when you need a magnet-free synchronous motor that fits naturally into a three-phase VFD architecture, particularly in variable-speed industrial applications. In either case, validate the final motor-drive-load assembly—not merely the motor nameplate—against torque, speed, current, temperature, noise, efficiency, protection, and duty-cycle requirements.

References

Editorial note: This article is intended for engineering education and preliminary product selection. Final motor, inverter, rotor-position sensing, protection, thermal, mechanical, EMC, and safety decisions must be validated using the chosen supplier’s technical documentation and testing in the intended end-product environment.

LATEST

INFORMATION

Get the latest product information of the company

%{tishi_zhanwei}%

CONTACT US

Telephone: +86 13305761511
Email: info@cntecho.com

Add: RM. 602, BUILDING B, NO.1551 SHUANGSHUI RD., LUQIAO DIST., TAIZHOU CITY, ZHEJIANG, CHINA

 


Copyright © 2026 TECHO ELECTRICAL & MECHANICAL (TAIZHOU) CO., LTD. All Rights Reserved.

Business License

Search for the product name you want to search

TECHO ELECTRICAL & MECHANICAL

%{tishi_zhanwei}%