TECHO ELECTRICAL & MECHANICAL

BLOG

Jun 26,2026

QJ Deep Well Submersible Pump | High‑Head Water Supply

The QJ deep well submersible pump delivers high‑head, high‑efficiency groundwater extraction for agricultural, municipal, and industrial water supply systems.


Introduction: The Engineering of Deep Aquifer Extraction

The QJ series deep well submersible pump is a vertically integrated, multi-stage centrifugal pump-motor unit engineered specifically for groundwater extraction from boreholes and wells exceeding 25 meters in depth. Unlike surface-mounted pumps limited by atmospheric suction constraints, the QJ series operates fully submerged at the aquifer level, utilizing positive pressure head to lift water from depths of 25 meters to over 300 meters. This fundamental design principle eliminates the 10.33-meter theoretical suction limit imposed by atmospheric pressure, enabling reliable water supply from deep confined aquifers.

Designed in accordance with GB/T 2816 and IEC 60034-1 standards, the QJ series features a slender, modular construction with the pump section positioned above a water-filled or oil-filled submersible motor. With flow capacities from 5 m³/h to 600 m³/h, heads up to 300 meters, and power ratings from 0.75 kW to 450 kW, the QJ series addresses the complete spectrum of groundwater extraction requirements.

1. Deep Well Pumping Fundamentals: Physics & Hydraulics

1.1 Atmospheric Limitations & Submersible Advantage

The maximum theoretical suction lift for any surface-mounted pump is determined by atmospheric pressure:

Hsuction,max = Patm / (ρ × g) = 101325 / (1000 × 9.81) ≈ 10.33 m

The QJ series overcomes this limitation by operating below the water surface, where the pump inlet is always under positive pressure:

Pinlet = Patm + ρghsubmergence

1.2 Multi-Stage Head Accumulation

Htotal = n × Hstage × ηstage

Example Calculation: 
For a QJ100-523-4 pump extracting water from 80 m depth with 20 m discharge pressure: 
Required head: Htotal = 80 + 20 = 100 m 
Stage head: 5 m/stage 
Stages required: n = 100 / 5 = 20 stages 
Selected pump: 23 stages (provides 115 m head with margin for drawdown and friction)

1.3 Hydraulic Power & Efficiency

Pshaft = (ρ × g × Q × H) / (1000 × ηoverall)

Practical Calculation Example: 
For a QJ200-80-55 pump (Q=80 m³/h = 0.0222 m³/s, H=150 m, ηoverall = 0.78): 
Pshaft = (1000 × 9.81 × 0.0222 × 150) / (1000 × 0.78) ≈ 41.9 kW 
The installed 55 kW motor provides adequate service factor for voltage fluctuation and transient overload conditions.

1.4 Well Drawdown & Aquifer Hydraulics

Hdynamic = Hstatic + s   |   s = (Q / 2πT) × ln(R / rw)

Critical Design Rule: The QJ pump must be set at least 3–5 meters below the anticipated maximum dynamic water level to prevent intake vortex formation and air entrainment.

2. QJ Series Technical Specifications

2.1 General Operating Parameters

ParameterSpecification
Pump TypeVertical multi-stage submersible centrifugal pump
Standard ComplianceGB/T 2816, IEC 60034-1
Power Range0.75 kW – 450 kW
Flow Range5 m³/h – 600 m³/h
Head Range11 m – 300 m
Voltage / FrequencyThree-phase 380 V / 50 Hz (standard); 660 V, 3000 V, 6000 V (high-power)
Rotational Speed2850 RPM (2-pole, 50 Hz); 3450 RPM (2-pole, 60 Hz)
Well Casing Diameter100 mm – 400 mm (4" – 16")
Submergence Requirement≥ 1 m below dynamic water level; ≥ 3 m above well bottom
Medium Temperature≤ 40°C (standard); ≤ 80°C (high-temp option)
Sand Content≤ 0.01% (150 g/m³ maximum for standard construction)
Protection / InsulationIP68 (continuous submersion) / Class F (155°C)

2.2 Model Nomenclature

Example: 100QJ5-23-4 
100: Applicable minimum well casing diameter = 100 mm (4 inch) 
QJ: QJ series deep well submersible pump 
5: Design flow rate = 5 m³/h 
23: Total head = 23 m 
4: Motor power = 4 kW

Variant Codes:

  • QJ: Standard cast iron construction
  • QJ-S: Full stainless steel construction (AISI 304/316)
  • QJ-H / QJ-R / QJ-K: High-head, Hot water, or Mine drainage variants

3. Performance Data Tables

3.1 Small-Duty Range: 100 mm Well Casing (4"), 0.75 kW – 7.5 kW

ModelFlow Q (m³/h)Head H (m)Power P (kW)StagesEfficiency η (%)
100QJ2-50/8-1.12501.1860
100QJ5-100/15-351003.01568
100QJ8-100/14-481004.01470
100QJ8-200/27-7.582007.52772

3.2 Medium-Duty Range: 150 mm – 200 mm Well Casing (6" – 8")

ModelFlow Q (m³/h)Head H (m)Power P (kW)StagesEfficiency η (%)
150QJ20-100/10-1120100111072
150QJ32-150/12-2232150221276
200QJ50-100/6-225010022676
200QJ80-150/6-458015045680

3.3 Large-Duty Range: 250 mm – 400 mm Well Casing (10" – 16")

ModelFlow Q (m³/h)Head H (m)Power P (kW)StagesEfficiency η (%)
250QJ100-100/4-4510010045480
300QJ200-150/6-132200150132683
300QJ300-200/4-200300200200485
400QJ500-100/2-200500100200285
400QJ600-50/1-13260050132184

Note: Efficiency values represent overall pump-motor efficiency at the Best Efficiency Point. Stage count indicates the number of impeller/diffuser pairs.

4. Structural Design & Material Engineering

4.1 Pump Section Architecture

ComponentMaterialFunction
ImpellerCast iron / Stainless steelConverts rotational energy to fluid kinetic energy
DiffuserCast iron / Stainless steelConverts kinetic energy to pressure; guides flow
Pump ShaftStainless steel (2Cr13 / 304 / 316)Transmits torque from motor; resists corrosion
Bearing BushRubber or PTFERadial support for pump shaft; wear compensation

4.2 Submersible Motor Design

ParameterWater-Filled MotorOil-Filled Motor
Cooling MediumWater (well water or deionized)Transformer oil (insulating oil)
BearingsWater-lubricated rubber bearingsOil-lubricated ball/roller bearings
MaintenanceMinimal; water replacement every 2–3 yearsOil replacement every 1–2 years
Temperature Limit≤ 40°C (standard)≤ 80°C (standard)

The submersible motor incorporates a Kingsbury-type or tilting-pad thrust bearing to absorb the substantial downward hydraulic thrust generated by the multi-stage impeller arrangement.

5. Installation Engineering & Well Design

5.1 Well Casing Sizing & Pump Setting Depth

Dcasing ≥ Dpump + 2 × Cclearance   |   Dsetting = Hstatic + smax + 1 m (safety) + 3 m (bottom clearance)

5.2 Cable Sizing & Voltage Drop

Voltage Drop (%) = (√3 × I × L × Rcable / Vnominal) × 100

Maximum allowable voltage drop: 5% (3% recommended for optimal motor performance). Undersized cables lead to increased motor current, reduced efficiency, and potential starting failure.

6. Application Engineering & Selection Guidelines

6.1 Duty Point & Aquifer Yield Matching

The optimal pump selection positions the system operating point at or near the Best Efficiency Point (BEP): 
Qoperating ≈ 0.8 × QBEP to 1.05 × QBEP

The pump flow rate must not exceed the sustainable aquifer yield: 
Qpump ≤ 0.9 × Qaquifer

6.2 Typical Application Scenarios

ApplicationRecommended Model RangeKey Selection Criteria
Agricultural irrigation (large farms)200QJ80-100 to 300QJ200-100High flow; continuous duty; energy efficiency
Municipal water supply (cities)250QJ140-150 to 400QJ400-100Very high flow; multiple pump configuration; SCADA
Industrial process water150QJ32-100 to 300QJ200-150Water quality compliance; continuous duty
Mine dewatering200QJ50-200 to 250QJ140-200Abrasion resistance; high head; reliability
Geothermal extraction200QJ80-150 to 300QJ200-150High temperature tolerance; corrosion resistance

7. Control Systems & Protection

7.1 Standard Control & VFD Operation

The QJ series is compatible with VFD operation for soft starting, flow modulation, and energy savings. VFD constraints include a minimum frequency of 30 Hz to maintain adequate cooling and bearing lubrication, and sine wave filters are recommended for cable runs >100 m.

7.2 Maximum Starts Per Hour

Motor PowerMax Starts/Hour (Single-Phase)Max Starts/Hour (Three-Phase)
≤ 0.75 kW300300
1.1 – 4.0 kW100300
5.5 – 22 kW50100
≥ 30 kW2050

8. Maintenance Protocol & Troubleshooting

8.1 Scheduled Maintenance

Inspection ItemFrequencyAction
Discharge pressure & flowWeeklyCompare to baseline; investigate deviations >10%
Water quality (sand content)Monthly>150 g/m³ requires investigation; >500 g/m³ shutdown
Motor insulation resistanceAnnuallyMegger test; >5 MΩ minimum
Pump lift & inspectionEvery 2–3 yearsInspect impellers, diffusers, bearings, seals

8.2 Common Faults & Remedies

SymptomProbable CauseRemedy
Reduced flow/headImpeller wear; sand erosionLift pump; inspect impellers; replace worn stages
Motor overload/tripHigh sand content; binding bearingsCheck water quality; inspect bearings; verify supply
Motor overheatingInsufficient cooling water flowVerify submergence depth; check cooling circuit
Frequent cyclingUndersized pressure tank; leakInstall larger pressure tank; repair leaks

9. Ordering Information & Custom Engineering

9.1 Required Specification Data

ParameterExample Value
Pump Model200QJ50-100/6-22
Well Casing Diameter200 mm (8 inch)
Static Water Level / Drawdown45 m / 15 m
Required Flow / Total Dynamic Head50 m³/h / 100 m
Fluid Temperature / Sand Content≤ 30°C / < 50 g/m³
Motor TypeWater-filled

9.2 Custom Engineering Options

  • AISI 304/316 full stainless steel: For corrosive groundwater (high chloride, acidic, or saline)
  • High-chrome impellers: For abrasive water with elevated sand content
  • Hot water execution: Up to 80°C with high-temperature seals and motor cooling
  • High-voltage motors: 3000 V or 6000 V for installations >200 kW (reduces cable size)
  • SCADA integration: Remote monitoring of flow, pressure, power, vibration, and temperature

10. Why Choose QJ Series for Your Groundwater Extraction?

Engineering CriterionQJ Series Advantage
Depth CapabilityExtracts from 25 m to 300+ m; eliminates atmospheric suction limitations
High EfficiencyMulti-stage optimization achieves 65–82% overall pump-motor efficiency
Modular DesignCustomizable stage count for precise head matching; reduced inventory
ReliabilitySubmersible motor eliminates surface weather exposure; IP68 protection
Energy SavingsIE3 motor option; VFD compatibility for variable-demand systems
Low MaintenanceWater-filled or oil-filled motors with 2–3 year service intervals
Application VersatilityFlow range 5–600 m³/h; covers domestic to municipal-scale water supply

Get a Free Custom Quote for QJ Deep Well Submersible Pumps

Choose TITECHO's QJ series for high-head groundwater extraction, superior hydraulic efficiency, and reliable deep well pumping. Our team responds within 24 hours!

📞 +86 13305761511

✉️ info@cntecho.com

💬 WhatsApp: Nancy / Jahor

Get Free Custom Quote Now → 

LATEST

INFORMATION

Get the latest product information of the company

%{tishi_zhanwei}%

CONTACT US

Telephone: +86 13305761511
Email: info@cntecho.com

Add: RM. 602, BUILDING B, NO.1551 SHUANGSHUI RD., LUQIAO DIST., TAIZHOU CITY, ZHEJIANG, CHINA

 


Copyright © 2026 TECHO ELECTRICAL & MECHANICAL (TAIZHOU) CO., LTD. All Rights Reserved.

Business License

Search for the product name you want to search

TECHO ELECTRICAL & MECHANICAL

%{tishi_zhanwei}%