QJ Deep Well Submersible Pump | High‑Head Water Supply
The QJ deep well submersible pump delivers high‑head, high‑efficiency groundwater extraction for agricultural, municipal, and industrial water supply systems.
Introduction: The Engineering of Deep Aquifer Extraction
The QJ series deep well submersible pump is a vertically integrated, multi-stage centrifugal pump-motor unit engineered specifically for groundwater extraction from boreholes and wells exceeding 25 meters in depth. Unlike surface-mounted pumps limited by atmospheric suction constraints, the QJ series operates fully submerged at the aquifer level, utilizing positive pressure head to lift water from depths of 25 meters to over 300 meters. This fundamental design principle eliminates the 10.33-meter theoretical suction limit imposed by atmospheric pressure, enabling reliable water supply from deep confined aquifers.
Designed in accordance with GB/T 2816 and IEC 60034-1 standards, the QJ series features a slender, modular construction with the pump section positioned above a water-filled or oil-filled submersible motor. With flow capacities from 5 m³/h to 600 m³/h, heads up to 300 meters, and power ratings from 0.75 kW to 450 kW, the QJ series addresses the complete spectrum of groundwater extraction requirements.
1. Deep Well Pumping Fundamentals: Physics & Hydraulics
1.1 Atmospheric Limitations & Submersible Advantage
The maximum theoretical suction lift for any surface-mounted pump is determined by atmospheric pressure:
Hsuction,max = Patm / (ρ × g) = 101325 / (1000 × 9.81) ≈ 10.33 m
The QJ series overcomes this limitation by operating below the water surface, where the pump inlet is always under positive pressure:
Pinlet = Patm + ρghsubmergence
1.2 Multi-Stage Head Accumulation
Htotal = n × Hstage × ηstage
Example Calculation:
For a QJ100-523-4 pump extracting water from 80 m depth with 20 m discharge pressure:
Required head: Htotal = 80 + 20 = 100 m
Stage head: 5 m/stage
Stages required: n = 100 / 5 = 20 stages
Selected pump: 23 stages (provides 115 m head with margin for drawdown and friction)
1.3 Hydraulic Power & Efficiency
Pshaft = (ρ × g × Q × H) / (1000 × ηoverall)
Practical Calculation Example:
For a QJ200-80-55 pump (Q=80 m³/h = 0.0222 m³/s, H=150 m, ηoverall = 0.78):
Pshaft = (1000 × 9.81 × 0.0222 × 150) / (1000 × 0.78) ≈ 41.9 kW
The installed 55 kW motor provides adequate service factor for voltage fluctuation and transient overload conditions.
1.4 Well Drawdown & Aquifer Hydraulics
Hdynamic = Hstatic + s | s = (Q / 2πT) × ln(R / rw)
Critical Design Rule: The QJ pump must be set at least 3–5 meters below the anticipated maximum dynamic water level to prevent intake vortex formation and air entrainment.
2. QJ Series Technical Specifications
2.1 General Operating Parameters
| Parameter | Specification |
|---|---|
| Pump Type | Vertical multi-stage submersible centrifugal pump |
| Standard Compliance | GB/T 2816, IEC 60034-1 |
| Power Range | 0.75 kW – 450 kW |
| Flow Range | 5 m³/h – 600 m³/h |
| Head Range | 11 m – 300 m |
| Voltage / Frequency | Three-phase 380 V / 50 Hz (standard); 660 V, 3000 V, 6000 V (high-power) |
| Rotational Speed | 2850 RPM (2-pole, 50 Hz); 3450 RPM (2-pole, 60 Hz) |
| Well Casing Diameter | 100 mm – 400 mm (4" – 16") |
| Submergence Requirement | ≥ 1 m below dynamic water level; ≥ 3 m above well bottom |
| Medium Temperature | ≤ 40°C (standard); ≤ 80°C (high-temp option) |
| Sand Content | ≤ 0.01% (150 g/m³ maximum for standard construction) |
| Protection / Insulation | IP68 (continuous submersion) / Class F (155°C) |
2.2 Model Nomenclature
Example: 100QJ5-23-4
100: Applicable minimum well casing diameter = 100 mm (4 inch)
QJ: QJ series deep well submersible pump
5: Design flow rate = 5 m³/h
23: Total head = 23 m
4: Motor power = 4 kW
Variant Codes:
- QJ: Standard cast iron construction
- QJ-S: Full stainless steel construction (AISI 304/316)
- QJ-H / QJ-R / QJ-K: High-head, Hot water, or Mine drainage variants
3. Performance Data Tables
3.1 Small-Duty Range: 100 mm Well Casing (4"), 0.75 kW – 7.5 kW
| Model | Flow Q (m³/h) | Head H (m) | Power P (kW) | Stages | Efficiency η (%) |
|---|---|---|---|---|---|
| 100QJ2-50/8-1.1 | 2 | 50 | 1.1 | 8 | 60 |
| 100QJ5-100/15-3 | 5 | 100 | 3.0 | 15 | 68 |
| 100QJ8-100/14-4 | 8 | 100 | 4.0 | 14 | 70 |
| 100QJ8-200/27-7.5 | 8 | 200 | 7.5 | 27 | 72 |
3.2 Medium-Duty Range: 150 mm – 200 mm Well Casing (6" – 8")
| Model | Flow Q (m³/h) | Head H (m) | Power P (kW) | Stages | Efficiency η (%) |
|---|---|---|---|---|---|
| 150QJ20-100/10-11 | 20 | 100 | 11 | 10 | 72 |
| 150QJ32-150/12-22 | 32 | 150 | 22 | 12 | 76 |
| 200QJ50-100/6-22 | 50 | 100 | 22 | 6 | 76 |
| 200QJ80-150/6-45 | 80 | 150 | 45 | 6 | 80 |
3.3 Large-Duty Range: 250 mm – 400 mm Well Casing (10" – 16")
| Model | Flow Q (m³/h) | Head H (m) | Power P (kW) | Stages | Efficiency η (%) |
|---|---|---|---|---|---|
| 250QJ100-100/4-45 | 100 | 100 | 45 | 4 | 80 |
| 300QJ200-150/6-132 | 200 | 150 | 132 | 6 | 83 |
| 300QJ300-200/4-200 | 300 | 200 | 200 | 4 | 85 |
| 400QJ500-100/2-200 | 500 | 100 | 200 | 2 | 85 |
| 400QJ600-50/1-132 | 600 | 50 | 132 | 1 | 84 |
Note: Efficiency values represent overall pump-motor efficiency at the Best Efficiency Point. Stage count indicates the number of impeller/diffuser pairs.
4. Structural Design & Material Engineering
4.1 Pump Section Architecture
| Component | Material | Function |
|---|---|---|
| Impeller | Cast iron / Stainless steel | Converts rotational energy to fluid kinetic energy |
| Diffuser | Cast iron / Stainless steel | Converts kinetic energy to pressure; guides flow |
| Pump Shaft | Stainless steel (2Cr13 / 304 / 316) | Transmits torque from motor; resists corrosion |
| Bearing Bush | Rubber or PTFE | Radial support for pump shaft; wear compensation |
4.2 Submersible Motor Design
| Parameter | Water-Filled Motor | Oil-Filled Motor |
|---|---|---|
| Cooling Medium | Water (well water or deionized) | Transformer oil (insulating oil) |
| Bearings | Water-lubricated rubber bearings | Oil-lubricated ball/roller bearings |
| Maintenance | Minimal; water replacement every 2–3 years | Oil replacement every 1–2 years |
| Temperature Limit | ≤ 40°C (standard) | ≤ 80°C (standard) |
The submersible motor incorporates a Kingsbury-type or tilting-pad thrust bearing to absorb the substantial downward hydraulic thrust generated by the multi-stage impeller arrangement.
5. Installation Engineering & Well Design
5.1 Well Casing Sizing & Pump Setting Depth
Dcasing ≥ Dpump + 2 × Cclearance | Dsetting = Hstatic + smax + 1 m (safety) + 3 m (bottom clearance)
5.2 Cable Sizing & Voltage Drop
Voltage Drop (%) = (√3 × I × L × Rcable / Vnominal) × 100
Maximum allowable voltage drop: 5% (3% recommended for optimal motor performance). Undersized cables lead to increased motor current, reduced efficiency, and potential starting failure.
6. Application Engineering & Selection Guidelines
6.1 Duty Point & Aquifer Yield Matching
The optimal pump selection positions the system operating point at or near the Best Efficiency Point (BEP):
Qoperating ≈ 0.8 × QBEP to 1.05 × QBEP
The pump flow rate must not exceed the sustainable aquifer yield:
Qpump ≤ 0.9 × Qaquifer
6.2 Typical Application Scenarios
| Application | Recommended Model Range | Key Selection Criteria |
|---|---|---|
| Agricultural irrigation (large farms) | 200QJ80-100 to 300QJ200-100 | High flow; continuous duty; energy efficiency |
| Municipal water supply (cities) | 250QJ140-150 to 400QJ400-100 | Very high flow; multiple pump configuration; SCADA |
| Industrial process water | 150QJ32-100 to 300QJ200-150 | Water quality compliance; continuous duty |
| Mine dewatering | 200QJ50-200 to 250QJ140-200 | Abrasion resistance; high head; reliability |
| Geothermal extraction | 200QJ80-150 to 300QJ200-150 | High temperature tolerance; corrosion resistance |
7. Control Systems & Protection
7.1 Standard Control & VFD Operation
The QJ series is compatible with VFD operation for soft starting, flow modulation, and energy savings. VFD constraints include a minimum frequency of 30 Hz to maintain adequate cooling and bearing lubrication, and sine wave filters are recommended for cable runs >100 m.
7.2 Maximum Starts Per Hour
| Motor Power | Max Starts/Hour (Single-Phase) | Max Starts/Hour (Three-Phase) |
|---|---|---|
| ≤ 0.75 kW | 300 | 300 |
| 1.1 – 4.0 kW | 100 | 300 |
| 5.5 – 22 kW | 50 | 100 |
| ≥ 30 kW | 20 | 50 |
8. Maintenance Protocol & Troubleshooting
8.1 Scheduled Maintenance
| Inspection Item | Frequency | Action |
|---|---|---|
| Discharge pressure & flow | Weekly | Compare to baseline; investigate deviations >10% |
| Water quality (sand content) | Monthly | >150 g/m³ requires investigation; >500 g/m³ shutdown |
| Motor insulation resistance | Annually | Megger test; >5 MΩ minimum |
| Pump lift & inspection | Every 2–3 years | Inspect impellers, diffusers, bearings, seals |
8.2 Common Faults & Remedies
| Symptom | Probable Cause | Remedy |
|---|---|---|
| Reduced flow/head | Impeller wear; sand erosion | Lift pump; inspect impellers; replace worn stages |
| Motor overload/trip | High sand content; binding bearings | Check water quality; inspect bearings; verify supply |
| Motor overheating | Insufficient cooling water flow | Verify submergence depth; check cooling circuit |
| Frequent cycling | Undersized pressure tank; leak | Install larger pressure tank; repair leaks |
9. Ordering Information & Custom Engineering
9.1 Required Specification Data
| Parameter | Example Value |
|---|---|
| Pump Model | 200QJ50-100/6-22 |
| Well Casing Diameter | 200 mm (8 inch) |
| Static Water Level / Drawdown | 45 m / 15 m |
| Required Flow / Total Dynamic Head | 50 m³/h / 100 m |
| Fluid Temperature / Sand Content | ≤ 30°C / < 50 g/m³ |
| Motor Type | Water-filled |
9.2 Custom Engineering Options
- AISI 304/316 full stainless steel: For corrosive groundwater (high chloride, acidic, or saline)
- High-chrome impellers: For abrasive water with elevated sand content
- Hot water execution: Up to 80°C with high-temperature seals and motor cooling
- High-voltage motors: 3000 V or 6000 V for installations >200 kW (reduces cable size)
- SCADA integration: Remote monitoring of flow, pressure, power, vibration, and temperature
10. Why Choose QJ Series for Your Groundwater Extraction?
| Engineering Criterion | QJ Series Advantage |
|---|---|
| Depth Capability | Extracts from 25 m to 300+ m; eliminates atmospheric suction limitations |
| High Efficiency | Multi-stage optimization achieves 65–82% overall pump-motor efficiency |
| Modular Design | Customizable stage count for precise head matching; reduced inventory |
| Reliability | Submersible motor eliminates surface weather exposure; IP68 protection |
| Energy Savings | IE3 motor option; VFD compatibility for variable-demand systems |
| Low Maintenance | Water-filled or oil-filled motors with 2–3 year service intervals |
| Application Versatility | Flow range 5–600 m³/h; covers domestic to municipal-scale water supply |
Get a Free Custom Quote for QJ Deep Well Submersible Pumps
Choose TITECHO's QJ series for high-head groundwater extraction, superior hydraulic efficiency, and reliable deep well pumping. Our team responds within 24 hours!
📞 +86 13305761511
✉️ info@cntecho.com
💬 WhatsApp: Nancy / Jahor
Related News
LATEST
INFORMATION
Get the latest product information of the company
NAVIGATION
PRODUCTS
CONTACT US
Telephone: +86 13305761511
Email: info@cntecho.com
Add: RM. 602, BUILDING B, NO.1551 SHUANGSHUI RD., LUQIAO DIST., TAIZHOU CITY, ZHEJIANG, CHINA
Copyright © 2026 TECHO ELECTRICAL & MECHANICAL (TAIZHOU) CO., LTD. All Rights Reserved.