The L Series horizontal single-stage centrifugal pump represents one of the most widely adopted pump configurations in industrial, commercial, and municipal fluid handling applications worldwide. Designed in accordance with DIN 24255 / EN 733 international standards, the L Series combines robust construction, standardized dimensions, and versatile material options to deliver reliable performance across an extensive duty range.

Unlike specialized pump designs optimized for narrow application windows, the L Series excels as a general-purpose workhorse — capable of handling clean and slightly contaminated liquids across water supply, HVAC, irrigation, process cooling, and light industrial applications. Its back-pull-out design enables rapid maintenance without disturbing piping connections, while the standardized flange dimensions ensure seamless interchangeability with other DIN-compliant pump brands.

2. Design Standards & Construction Philosophy

2.1 Compliance Standards

StandardScopeRelevance
DIN 24255 / EN 733End-suction centrifugal pumpsDimensions, performance, interface
ISO 2858 / ISO 5199Global interchangeability / Class IIMain dimensions, design & testing
IEC 60034Rotating electrical machinesMotor specs, efficiency, protection

2.2 Structural Design Features

FeatureEngineering Benefit
Back-pull-out designMaintenance time reduced 60–80% without pipe disturbance
Bearing bracket with supporting footIsolates pipe strain from bearing alignment
Flexible coupling driveEasy alignment; motor can be reused with replacement pump

2.3 Model Nomenclature System

L □□ - □□□ / □□□ - [A/B/C]
        │  │    │     │      └── Impeller trim code (optional)
        │  │    │     └───────── Nominal impeller diameter (mm)
        │  │    └─────────────── Nominal discharge diameter (mm)
        │  └───────────────────── Nominal suction diameter (mm)
        └──────────────────────── Series designation (L = Horizontal Single-Stage)
        Example: L 80-50-200A
        80: Suction DN80 | 50: Discharge DN50 | 200: Base impeller Ø | A: First trim

3. Technical Specifications & Performance Range

3.1 Standard Performance Parameters

ParameterSpecification Range
Flow Rate (Q)2 – 2,300 m³/h
Total Head (H)2 – 150 m (Single-stage limit)
Speed (n)1,450 / 2,900 r/min (50 Hz)
Max Working Pressure10 bar (standard); 16 bar (optional)
Efficiency at BEP55% – 85%

3.2 Performance Data — Standard EN 733 Sizes (50 Hz, 2,900 r/min)

ModelSuction × DischargeImpeller ØFlow RangeHead RangeEff. BEP
L 50-32-20050 × 32200 mm12 – 35 m³/h15 – 45 m60 – 68%
L 65-40-25065 × 40250 mm25 – 80 m³/h28 – 75 m68 – 76%
L 80-50-25080 × 50250 mm45 – 130 m³/h25 – 65 m72 – 78%
L 100-65-315100 × 65315 mm100 – 250 m³/h45 – 100 m75 – 82%
L 150-100-315150 × 100315 mm220 – 550 m³/h35 – 80 m80 – 85%

4. Hydraulic Design & Performance Characteristics

4.1 Impeller Design Parameters

Htheoretical = (u2 × vu2) / g   |   Q1/Q2 = (D1/D2)3   |   H1/H2 = (D1/D2)2

Trim CodeDiameter ReductionHead ReductionEfficiency Impact
A (First trim)5%9.75%-2% to -3%
B (Second trim)10%19%-4% to -6%
C (Third trim)15%27.75%-7% to -10%

4.2 Specific Speed and Impeller Geometry

Ns (SI)Impeller TypeL Series Application
10 – 30Low-specific-speed radialHigh head, low flow (L 32-20, L 40-25)
30 – 60Medium-specific-speed radialGeneral purpose (L 50-32, L 65-40)
60 – 100High-specific-speed radial / mixedMedium flow (L 80-50, L 100-65)
100 – 150Mixed flowHigh flow, low head (L 125-80, L 150-100)

5. Material Specifications

5.2 Material Selection by Application

ApplicationFluidRecommended Configuration
Potable water supplyClean water < 50°CCast Iron / SS 420 / Carbon-Ceramic-Viton
Cooling tower waterTreated water < 40°CCast Iron / Bronze / SS 420 / Carbon-Ceramic-EPDM
Boiler feed (condensate)Deaerated water < 105°CCast Steel / SS 316 / SiC-SiC-Viton
Seawater coolingSeawater < 40°CBronze / Ni-Al Bronze / SS 316 / SiC-SiC-Viton
Food & beverageProcess water, CIP < 100°CSS 316L / SS 316L / SiC-SiC-EPDM

6. Motor Selection & Drive Configuration

6.1 Motor Power Calculation

Phydraulic = (Q × H) / 367 [kW]   |   Pmotor = (Pshaft × SF) / ηm

Application ConditionService Factor (SF)
Clean water, steady load, continuous duty1.10
Slightly contaminated water, intermittent solids1.15
High ambient temperature (> 40°C) / High altitude1.05–1.10

6.3 Starting Method Selection

Motor PowerStarting MethodApplication Notes
≤ 3.0 kWDOLStandard for small pumps
3.0 – 11 kWDOL or Star-DeltaY-Δ reduces starting stress
11 – 30 kWStar-Delta or Soft StarterSoft starter recommended for large systems
> 75 kWSoft Starter or VFDVFD for variable flow systems

7. Installation & Commissioning

7.2 Alignment Tolerances

Δh = α × L × ΔT   (Thermal Growth Compensation)

ParameterCold AlignmentHot Alignment
Angular misalignment< 0.05 mm/100 mm< 0.08 mm/100 mm
Parallel offset< 0.05 mm< 0.10 mm
Soft foot (per foot)< 0.05 mm—

7.3 Piping Requirements

Flange Size (DN)Max Force (N)Max Moment (N·m)
32 – 5050050
65 – 80800100
100 – 1251,200200
150 – 2002,000400

8. Operating Performance Monitoring

8.1 Key Performance Indicators (KPIs)

ParameterNormal RangeAlarmCritical
Suction pressurePer design< 0.5 bar (gauge)< 0 bar
Bearing temperature< 70°C70–80°C> 80°C
Motor current85–100% FLA> 105% continuous> 115%
Vibration (velocity)< 4.5 mm/s4.5–7.1 mm/s> 7.1 mm/s

8.2 Efficiency Monitoring

ηpump = Phydraulic / Pshaft = (ρgQH) / (Pmotor × ηmotor × ηcoupling)

9. Maintenance & Troubleshooting

9.1 Preventive Maintenance Schedule

IntervalComponentAction
WeeklySeal leakage / Bearing tempVisual inspection / Record readings
MonthlyVibration / CouplingMeasure and trend / Inspect spider
Semi-annuallyAlignment / Wear ringsLaser check / Measure clearances
AnnuallyImpeller / Casing / ShaftVisual inspection / Runout check

9.3 Wear Ring Clearance Maintenance

Pump Size (DN)New Clearance (mm)Max Allowable (mm)Efficiency Loss at Max
32 – 500.30 – 0.400.70 – 0.804 – 6%
65 – 800.40 – 0.500.90 – 1.105 – 8%
100 – 1250.50 – 0.651.10 – 1.406 – 10%
150 – 2000.65 – 0.801.40 – 1.808 – 12%

10. Application Engineering

10.1 Application Selection Matrix

ApplicationTypical ModelFlow (m³/h)Head (m)
HVAC chilled waterL 100-65-25080 – 15025 – 45
Cooling tower circulationL 125-80-250120 – 25015 – 35
Fire fighting (main)L 125-80-315150 – 30060 – 100
Raw water intakeL 200-150-400400 – 80020 – 40

10.3 Variable Speed (VFD) Applications

ParameterRecommended SettingPurpose
Minimum frequency25 Hz (50%)Prevent low-flow recirculation
Acceleration time5 – 10 sPrevent water hammer
Sleep functionEnableStop pump at zero demand

11. Comparative Analysis: L Series vs. Alternative Pump Types

Evaluation CriteriaL Series (DIN/EN)Inline CirculatorSplit-Case Double-Suction
Maintenance accessExcellent (back-pull-out)GoodExcellent
Efficiency at BEP70–85%60–75%80–90%
Maximum head (single)150 m30 m150 m
InterchangeabilityExcellent (DIN/EN)LimitedLimited

12. Quality Assurance & Certifications

CertificationStandardApplicability
CE MarkingEU Machinery Directive 2006/42/ECEuropean market
ISO 9001 / 14001ISO 9001:2015 / ISO 14001:2015Quality & Environmental
EN 733 / DIN 24255End-suction centrifugal pumpsDimensional & performance
WRAS / NSFBS 6920 / NSF 61Potable water applications

13. Conclusion

The L Series horizontal single-stage centrifugal pump represents a mature, standardized, and economically compelling solution for the vast majority of clean-fluid pumping applications. Its adherence to DIN 24255 / EN 733 standards ensures dimensional interchangeability with global suppliers, while the back-pull-out design minimizes lifecycle maintenance costs.

  • Proven reliability: Decades of field-proven performance across millions of installations worldwide.
  • Standardized maintenance: Readily available spare parts; no proprietary dependencies.
  • Low total cost of ownership: Simple construction, minimal wear parts, easy field service.

For general water supply, HVAC circulation, irrigation, process cooling, and light industrial duty, the L Series remains the technically sound and economically superior standard choice.

Get Expert Support for L Series Pump Selection

Choose TITECHO's L Series for standardized reliability, back-pull-out maintenance, and versatile fluid handling. Our engineering team responds within 24 hours!

📞 +86 13305761511

✉️ info@cntecho.com

💬 WhatsApp: Nancy / Jahor

Get Free Custom Quote Now → 

LATEST

INFORMATION

Get the latest product information of the company

%{tishi_zhanwei}%

CONTACT US

Telephone: +86 13305761511
Email: info@cntecho.com

Add: RM. 602, BUILDING B, NO.1551 SHUANGSHUI RD., LUQIAO DIST., TAIZHOU CITY, ZHEJIANG, CHINA

 


Copyright © 2026 TECHO ELECTRICAL & MECHANICAL (TAIZHOU) CO., LTD. All Rights Reserved.

Business License

Search for the product name you want to search

TECHO ELECTRICAL & MECHANICAL

%{tishi_zhanwei}%