TECHO ELECTRICAL & MECHANICAL

BLOG

Jun 25,2026

ISW Horizontal Inline Centrifugal Pump for HVAC & Water Supply

ISW horizontal inline centrifugal pumps deliver high‑efficiency water circulation for HVAC, building supply, industrial processes, and fire‑fighting systems with compact, space‑saving design.


Introduction: The Inline Revolution in Centrifugal Pump Design

The ISW series horizontal inline centrifugal pump is a single-stage, single-suction pump engineered for applications where space constraints, piping simplicity, and installation efficiency are paramount. Unlike conventional end-suction or split-case pumps that require complex piping configurations with 90° elbows and suction diffusers, the ISW series features a true inline design with suction and discharge flanges aligned on the same horizontal axis. This configuration enables straight-through piping, eliminating the need for directional changes at the pump and reducing both installation cost and hydraulic losses.

Designed in accordance with GB/T 5657-2013 (equivalent to ISO 2858) and GB 19762-2007 (energy efficiency limits for centrifugal pumps), the ISW series delivers hydraulic performance optimized for building water supply, HVAC circulation, industrial process transfer, and fire-fighting systems. With flow capacities from 1.1 m³/h to 520 m³/h, heads up to 153.6 meters, and power ratings from 0.18 kW to 110 kW, the ISW series addresses the complete spectrum of clean fluid handling requirements in modern infrastructure.

1. Inline Pump Technology: Hydraulic Principles

1.1 Straight-Through Flow Path

The defining engineering characteristic of the ISW series is its axial inline configuration. Fluid enters the pump suction flange, passes through the impeller in a single directional plane, and exits the discharge flange without directional change. This geometry eliminates elbow-induced turbulence, suction diffuser requirements, and complex piping geometry.

The hydraulic efficiency benefit of the inline configuration can be quantified by comparing the total system head loss:

Hsystem,inline = Hstatic + Hfriction,pipe + Hfriction,pump

Hsystem,endsuction = Hstatic + Hfriction,pipe + Helbow + Hdiffuser + Hfriction,pump

For typical installations, the elimination of the suction elbow and diffuser reduces system head by 0.5–1.5 meters, translating to 5–15% energy savings over the pump's operational lifetime.

1.2 Hydraulic Power & Pump Efficiency

Phydraulic = (ρ × g × Q × H) / (1000 × ηp)

Practical Calculation Example: 
For an ISW80-160 pump operating at rated conditions (Q=50 m³/h = 0.0139 m³/s, H=32 m), with ηp = 0.76: 
Phydraulic = (1000 × 9.81 × 0.0139 × 32) / (1000 × 0.76) ≈ 5.75 kW 
The installed 7.5 kW motor provides adequate service factor for startup torque and wear-induced efficiency degradation.

1.3 Specific Speed & Impeller Classification

Ns = n × √Q / H0.75

For the ISW100-200 pump (n=2900 RPM, Q=100 m³/h = 0.0278 m³/s, H=50 m): 
Ns = (2900 × √0.0278) / 500.75 ≈ 2580, indicating a mixed-flow impeller design optimized for medium-to-high flow and moderate head applications.

2. ISW Series Technical Specifications

2.1 General Operating Parameters

ParameterSpecification
Pump TypeSingle-stage single-suction horizontal inline centrifugal pump
Standard ComplianceGB/T 5657-2013 (ISO 2858), GB 19762-2007
Power Range0.18 kW – 110 kW
Flow Range1.1 m³/h – 520 m³/h
Head Range7 m – 153.6 m
Voltage / FrequencyThree-phase 380 V / 50 Hz (standard); optional voltages
Rotational Speed1450 RPM (4-pole); 2900 RPM (2-pole, 50 Hz)
Medium Temperature-10°C to +120°C (standard); up to +240°C (ISW-R)
Max Working Pressure1.6 MPa (16 bar)
Inlet/Outlet ConnectionFlanged (PN16); threaded (for small models)

2.2 Model Nomenclature

Example: ISW80-160 
ISW: ISW series horizontal inline centrifugal pump 
80: Inlet/outlet nominal diameter = 80 mm (3 inch) 
160: Impeller nominal diameter = 160 mm

Variant Codes:

  • A / B suffix: Trimmed impeller for reduced head at same flow
  • (I) suffix: High-flow variant with enlarged impeller eye
  • ISW-H: Corrosion-resistant variant (stainless steel or alloy)
  • ISW-R: Hot water variant with cooling jacket and high-temperature seals

3. Performance Data Tables

3.1 Small-Duty Range: DN15 – DN32 (0.18 kW – 4.0 kW)

ModelDN (mm)Flow Q (m³/h)Head H (m)η (%)RPMPower (kW)NPSHr (m)
ISW15-80151.1 / 1.5 / 2.08.5 / 8 / 726 / 34 / 3428000.182.3
ISW20-110201.8 / 2.5 / 3.316 / 15 / 13.525 / 34 / 3528000.372.3
ISW25-125252.8 / 4.0 / 5.220.6 / 20 / 1828 / 36 / 3529000.752.3
ISW32-100(I)324.4 / 6.3 / 8.313.2 / 12.5 / 11.348 / 54 / 5329000.752.0
ISW32-200(I)324.4 / 6.3 / 8.350.5 / 50 / 4826 / 33 / 3529004.02.0

3.2 Medium-Duty Range: DN40 – DN65 (0.55 kW – 15 kW)

ModelDN (mm)Flow Q (m³/h)Head H (m)η (%)RPMPower (kW)NPSHr (m)
ISW40-125404.4 / 6.3 / 8.321 / 20 / 1841 / 46 / 4329001.12.3
ISW50-160508.3 / 12.5 / 16.333 / 32 / 3040 / 48 / 5029003.02.3
ISW65-1256517.5 / 25 / 32.522 / 20 / 1850 / 58 / 5629003.02.5
ISW65-2506517.5 / 25 / 32.582 / 80 / 7438 / 48 / 502900152.5

3.3 Large-Duty Range: DN80 – DN100 (5.5 kW – 90 kW)

ModelDN (mm)Flow Q (m³/h)Head H (m)η (%)RPMPower (kW)NPSHr (m)
ISW80-160(I)8070 / 100 / 13036.5 / 32 / 2470 / 76 / 652900154.5
ISW100-160(I)10096 / 160 / 19236 / 32 / 2769 / 79 / 752900225.6
ISW100-250(I)10096 / 160 / 19283 / 80 / 7265 / 77 / 742900554.8
ISW100-35010060 / 100 / 120153.6 / 150 / 142.872 / 57 / 742900904.0

3.4 Heavy-Duty Range: DN125 – DN250 (11 kW – 110 kW)

ModelDN (mm)Flow Q (m³/h)Head H (m)η (%)RPMPower (kW)NPSHr (m)
ISW125-20012596 / 160 / 19255 / 50 / 46772900375.5
ISW150-315150140 / 200 / 26033.8 / 32 / 2870 / 78 / 781450302.5
ISW200-315(I)200280 / 400 / 52036 / 32 / 2673 / 80 / 751450554.0
ISW250-250250350 / 550 / 65022 / 20 / 1678 / 82 / 811450455.0

Note: Flow values are presented as minimum/rated/maximum operating points. Efficiency values correspond to the rated flow point. The (I) suffix denotes high-flow variants with enlarged impeller eye area.

4. Structural Design & Material Engineering

4.1 Pump Casing & Impeller Materials

ComponentStandard MaterialOptional MaterialApplication Driver
Pump CasingCast Iron (HT200)Stainless Steel, Ductile IronCorrosion resistance, pressure rating
ImpellerCast Iron (HT200)Bronze, Stainless SteelSeawater, chemical compatibility
Shaft45# Carbon Steel2Cr13, 304/316 SSCorrosion resistance, strength
Wear RingStainless Steel (2Cr13)Bronze, HastelloyAbrasion resistance

4.2 Inline Configuration Advantages

  • Space Efficiency: Footprint reduction of 40–60% vs. end-suction pumps; horizontal alignment eliminates vertical motor extensions.
  • Piping Simplification: Straight-through flanges eliminate the need for suction/discharge elbows and associated support structures.
  • Hydraulic Efficiency: Axial flow path minimizes pre-rotation and flow separation; lower NPSHr by 0.5–1.0 m.
  • Installation & Maintenance: No field alignment required; cartridge seal design allows replacement without pump disassembly.

4.3 Mechanical Seal System

Seal ComponentStandard ConfigurationHigh-Duty Configuration
Seal FacesCarbon vs. CeramicSilicon Carbide (SiC) vs. SiC
Secondary SealNBR O-ringsViton (FKM) or EPDM
SpringAISI 304 Stainless SteelHastelloy C
CoolingInternal recirculationExternal flush (for hot water >80°C)

5. Motor Engineering & Drive Options

5.1 Standard Motor Configuration

ParameterSpecification
Motor TypeTEFC three-phase induction motor
Efficiency ClassIE2 (standard); IE3 (premium efficiency option)
Poles / Speed2-pole (2900 RPM) or 4-pole (1450 RPM)
Insulation / ProtectionClass F (155°C) / IP55
Service Factor1.15

5.2 Variable Frequency Drive (VFD) Compatibility

The ISW series is fully compatible with VFD operation for energy-efficient flow control:

Q2 = Q1 × (f2 / f1)   |   H2 = H1 × (f2 / f1)2   |   P2 = P1 × (f2 / f1)3

Energy Savings Example: For an HVAC circulation system operating at 70% of design flow, P70% = 22 × (0.7)3 = 7.55 kW. Energy savings during part-load = 65.7% compared to constant-speed operation with throttling control.

6. Application Engineering & Selection Guidelines

6.1 Duty Point Selection & System Head

The optimal pump selection positions the system operating point at or near the Best Efficiency Point (BEP): 
Qoperating ≈ 0.8 × QBEP to 1.1 × QBEP

Htotal = Hstatic + Hfriction + Hpressure + Hvelocity

6.2 Typical Application Scenarios

ApplicationRecommended Model RangeKey Selection Criteria
High-rise building water supplyISW80-160 to ISW150-315Moderate-to-high head; constant pressure with VFD
HVAC chilled/hot waterISW50-125 to ISW200-400(I)Energy-efficient VFD; quiet operation; 4-pole for large flows
Industrial process coolingISW65-160 to ISW125-250Continuous duty; temperature tolerance; reliability
Boiler feed water (low-pressure)ISW40-200 to ISW80-250High temperature capability (ISW-R); NPSH verification
Fire-fighting jockey pumpISW80-160 to ISW125-200Maintain system pressure; automatic start on pressure drop
Municipal water distributionISW125-200 to ISW250-250Large flow; moderate head; reliability; redundancy

7. Installation, Operation & Maintenance

7.1 Installation Requirements

ParameterRequirement
FoundationRigid, level concrete pad or steel baseplate; anchor bolts for vibration isolation
Piping SupportIndependent pipe supports within 0.5 m of pump flanges; no pipe strain on pump
Suction ConditionsFlooded suction preferred; verify NPSHa > NPSHr + 0.5 m
Ambient Conditions≤ +40°C; adequate clearance for motor cooling air intake (minimum 0.3 m)

7.2 Maintenance Protocol

Inspection ItemFrequencyAction
Mechanical seal leakageMonthlyReplace if drip rate exceeds 5 drops/minute
Bearing temperatureMonthlyInvestigate if >80°C or ΔT >15°C from ambient
Vibration analysisQuarterlyISO 10816 criteria; velocity >4.5 mm/s RMS requires investigation
Motor current drawMonthlyCompare to baseline; investigate deviations >10%
Impeller wearAnnuallyInspect for erosion, corrosion, or cavitation pitting

8. Ordering Information & Custom Engineering

8.1 Required Specification Data

ParameterExample Value
Pump ModelISW100-160(I)
Fluid TypeChilled water / Hot water / Process water
Flow Rate (Q)160 m³/h
Total Dynamic Head (H)32 m
Fluid Temperature≤ 40°C (standard) / ≤ 120°C (hot water)
Material SpecificationStandard cast iron
Connection TypeFlanged PN16, DN100

8.2 Custom Engineering Options

  • ISW-H corrosion-resistant variant: Full stainless steel or alloy construction for chemical/seawater applications
  • ISW-R hot water variant: Cooling jacket, high-temperature seals for service up to +240°C
  • Special voltages/frequencies: 220 V, 415 V, 460 V; 60 Hz designs for export markets
  • Explosion-proof motors: ATEX/IECEx certified for Zone 1/Zone 2 hazardous areas
  • Double mechanical seal: Barrier fluid system for hazardous or crystallizing fluids

9. Why Choose ISW Series for Your Fluid Circulation Needs?

Engineering CriterionISW Series Advantage
Space EfficiencyInline design reduces footprint by 40–60% vs. end-suction pumps
Installation SimplicityStraight-through piping eliminates elbows; no field alignment required
Hydraulic EfficiencyAxial inlet minimizes pre-rotation losses; improves NPSH performance
Energy SavingsVFD-compatible for variable-flow systems; affinity law cubic power reduction
Maintenance AccessibilityCartridge seal replacement; back pull-out motor assembly (selected models)
VersatilityFlow range 1.1–520 m³/h; head range 7–153 m; covers all building services
Temperature RangeStandard -10°C to +120°C; ISW-R variant to +240°C
Global ComplianceGB/T 5657-2013 (ISO 2858), GB 19762-2007 certified

Get a Free Custom Quote for ISW Inline Centrifugal Pumps

Choose TITECHO's ISW series for space-saving inline design, superior hydraulic efficiency, and reliable fluid circulation. Our team responds within 24 hours!

📞 +86 13305761511

✉️ info@cntecho.com

💬 WhatsApp: Nancy / Jahor

Get Free Custom Quote Now → 

LATEST

INFORMATION

Get the latest product information of the company

%{tishi_zhanwei}%

CONTACT US

Telephone: +86 13305761511
Email: info@cntecho.com

Add: RM. 602, BUILDING B, NO.1551 SHUANGSHUI RD., LUQIAO DIST., TAIZHOU CITY, ZHEJIANG, CHINA

 


Copyright © 2026 TECHO ELECTRICAL & MECHANICAL (TAIZHOU) CO., LTD. All Rights Reserved.

Business License

Search for the product name you want to search

TECHO ELECTRICAL & MECHANICAL

%{tishi_zhanwei}%