Jun 25,2026
ISG Vertical Inline Centrifugal Pump for HVAC & Water Supply
ISG vertical inline centrifugal pumps provide high‑efficiency water circulation for HVAC, building supply, industrial processes, and municipal systems with a compact, space‑saving design.
Introduction: The Vertical Inline Advantage in Modern Pumping Infrastructure
The ISG series vertical inline centrifugal pump is a single-stage, single-suction pump engineered for applications where horizontal floor space is at a premium and vertical integration into piping systems is preferred. Unlike horizontal pumps that require significant footprint area, the ISG series features a true vertical inline design with suction and discharge flanges aligned on the same vertical centerline and sharing identical nominal diameters. This configuration enables the pump to be installed directly in the pipeline like a valve, dramatically reducing both installation footprint and structural support requirements.
Designed in accordance with ISO 2858 and JB/T 53058-90 standards, the ISG series represents the second generation of high-efficiency, energy-saving vertical pipeline pumps. With flow capacities from 1.5 m³/h to 6000 m³/h, heads up to 153.6 meters, and power ratings from 0.18 kW to 110 kW, the ISG series addresses the complete spectrum of industrial and urban water supply, high-rise building pressurization, HVAC circulation, fire-fighting systems, and long-distance water transfer applications.
1. Vertical Inline Pump Technology: Design Principles
1.1 Valve-Like Installation Concept
The defining engineering characteristic of the ISG series is its vertical inline configuration with identical inlet and outlet diameters on the same centerline:
- Compact footprint: The pump occupies minimal floor space, with the motor mounted vertically above the pump casing
- Piping simplification: Straight-through alignment eliminates the need for suction elbows, discharge elbows, and directional changes
- Structural efficiency: The pump can be supported by the piping itself or on a small foundation pad, reducing civil engineering costs
- Outdoor capability: With the addition of a protective canopy, the ISG series can operate in exposed environments without dedicated pump houses
Space Comparison: For a DN100 pump installation, the ISG series requires approximately 0.25 m² of floor space versus 0.8–1.2 m² for an equivalent horizontal end-suction pump with suction elbow and discharge piping. This represents a 70–80% footprint reduction — critical in congested mechanical rooms and equipment galleries.
1.2 Impeller-on-Motor-Shaft Architecture
The ISG series employs a direct-drive design with the impeller mounted directly on the motor's extended shaft, eliminating coupling and separate bearing housing, reducing overall height by 20–30%, and minimizing torsional oscillation for low vibration and quiet operation.
The axial load generated by the single-suction impeller is calculated as:
Faxial = ΔP × Aimpeller eye
Where:
Faxial = Axial thrust force (N)
ΔP = Pressure differential across impeller (Pa)
Aimpeller eye = Cross-sectional area of impeller eye (m²)
The motor thrust bearing is sized to absorb this load with a minimum safety factor of 2.0.
2. Hydraulic Fundamentals: Pump Performance Equations
2.1 Hydraulic Power & Pump Efficiency
Phydraulic = (ρ × g × Q × H) / (1000 × ηp)
Practical Calculation Example:
For an ISG80-200 pump operating at rated conditions (Q=50 m³/h = 0.0139 m³/s, H=50 m), with ηp = 0.76:
Phydraulic = (1000 × 9.81 × 0.0139 × 50) / (1000 × 0.76) ≈ 8.97 kW
The installed 15 kW motor provides adequate service factor for startup torque, wear-induced efficiency degradation, and voltage fluctuation tolerance.
2.2 System Head Calculation
Htotal = Hstatic + Hfriction + Hvelocity
Darcy-Weisbach Friction Loss:
Hf = f × (L / D) × (v2 / (2g))
Velocity Head:
Hv = v2 / (2g)
For ISG series applications, recommended pipe velocities range from 1.0 to 2.5 m/s on the discharge side and 0.8 to 1.8 m/s on the suction side to prevent cavitation and ensure efficient operation.
2.3 Specific Speed & Impeller Classification
Ns = n × √Q / H0.75
For the ISG100-250 pump (n=2900 RPM, Q=100 m³/h = 0.0278 m³/s, H=80 m):
Ns = (2900 × √0.0278) / 800.75 ≈ 1810, indicating a radial-to-mixed-flow impeller design optimized for moderate flow and moderate-to-high head applications.
3. ISG Series Technical Specifications
3.1 General Operating Parameters
| Parameter | Specification |
|---|---|
| Pump Type | Single-stage single-suction vertical inline centrifugal pump |
| Standard Compliance | ISO 2858, JB/T 53058-90 |
| Power Range | 0.18 kW – 110 kW |
| Flow Range | 1.5 m³/h – 6000 m³/h |
| Head Range | 5 m – 153.6 m |
| Voltage / Frequency | Three-phase 380 V / 50 Hz (standard); optional voltages |
| Rotational Speed | 1450 RPM (4-pole); 2900 RPM (2-pole); 970 RPM (6-pole) |
| Medium Temperature | -15°C to +80°C (standard); up to +240°C (high-temp variant) |
| Max Working Pressure | 1.6 MPa (16 bar) |
| Inlet/Outlet Connection | Flanged (PN16); threaded (for small models) |
3.2 Model Nomenclature
Example: ISG80-200
ISG: ISG series vertical inline centrifugal pump
80: Inlet/outlet nominal diameter = 80 mm (3 inch)
200: Impeller nominal diameter = 200 mm
Variant Codes:
- A / B suffix: Trimmed impeller for reduced head at same flow
- (I) suffix: High-flow variant with enlarged impeller eye
- ISG-H / ISG-IH: Corrosion-resistant / chemical variants
- ISG-R / ISG-GR: Hot water / high-temperature variants
- ISG-YG / ISG-EX: Oil pump / explosion-proof variants
4. Performance Data Tables
4.1 Small-Duty Range: DN15 – DN32 (0.18 kW – 4.0 kW)
| Model | DN (mm) | Flow Q (m³/h) | Head H (m) | η (%) | RPM | Power (kW) | NPSHr (m) |
|---|---|---|---|---|---|---|---|
| ISG15-80 | 15 | 1.1 / 1.5 / 2.0 | 8.5 / 8 / 7 | 26 / 34 / 34 | 2800 | 0.18 | 2.3 |
| ISG25-125 | 25 | 2.8 / 4.0 / 5.2 | 20.6 / 20 / 18 | 28 / 36 / 35 | 2900 | 0.75 | 2.3 |
| ISG32-100(I) | 32 | 4.4 / 6.3 / 8.3 | 13.2 / 12.5 / 11.3 | 48 / 54 / 53 | 2900 | 0.75 | 2.0 |
| ISG32-200(I) | 32 | 4.4 / 6.3 / 8.3 | 50.5 / 50 / 48 | 26 / 33 / 35 | 2900 | 4.0 | 2.0 |
4.2 Medium-Duty Range: DN40 – DN65 (0.55 kW – 15 kW)
| Model | DN (mm) | Flow Q (m³/h) | Head H (m) | η (%) | RPM | Power (kW) | NPSHr (m) |
|---|---|---|---|---|---|---|---|
| ISG40-160 | 40 | 4.4 / 6.3 / 8.3 | 33 / 32 / 30 | 35 / 40 / 40 | 2900 | 2.2 | 2.3 |
| ISG50-200 | 50 | 8.3 / 12.5 / 16.3 | 50 / 48 / 46 | 32 / 40 / 42 | 2900 | 5.5 | 2.3 |
| ISG65-160 | 65 | 17.5 / 25 / 32.5 | 35 / 32 / 28 | 48 / 56 / 55 | 2900 | 5.5 | 2.5 |
| ISG65-250 | 65 | 17.5 / 25 / 32.5 | 82 / 80 / 74 | 38 / 48 / 50 | 2900 | 15 | 2.5 |
4.3 Large-Duty Range: DN80 – DN100 (5.5 kW – 90 kW)
| Model | DN (mm) | Flow Q (m³/h) | Head H (m) | η (%) | RPM | Power (kW) | NPSHr (m) |
|---|---|---|---|---|---|---|---|
| ISG80-160(I) | 80 | 70 / 100 / 130 | 36.5 / 32 / 24 | 70 / 76 / 65 | 2900 | 15 | 4.5 |
| ISG100-160(I) | 100 | 96 / 160 / 192 | 36 / 32 / 27 | 69 / 79 / 75 | 2900 | 22 | 5.6 |
| ISG100-250(I) | 100 | 96 / 160 / 192 | 83 / 80 / 72 | 65 / 77 / 74 | 2900 | 55 | 4.8 |
| ISG100-350 | 100 | 60 / 100 / 120 | 153.6 / 150 / 142.8 | 72 / 57 / 74 | 2900 | 90 | 4.0 |
4.4 Heavy-Duty Range: DN125 – DN300 (11 kW – 132 kW)
| Model | DN (mm) | Flow Q (m³/h) | Head H (m) | η (%) | RPM | Power (kW) | NPSHr (m) |
|---|---|---|---|---|---|---|---|
| ISG125-250 | 125 | 96 / 160 / 192 | 87 / 80 / 73 | 75 | 2900 | 55 | 5.0 |
| ISG150-315 | 150 | 140 / 200 / 260 | 33.8 / 32 / 28 | 70 / 78 / 78 | 1450 | 30 | 2.5 |
| ISG200-315(I) | 200 | 280 / 400 / 520 | 36 / 32 / 26 | 73 / 80 / 75 | 1450 | 55 | 4.0 |
| ISG300-380 | 300 | 480 / 720 / 900 | 48 / 44 / 34 | 84 | 970 | 132 | 5.0 |
Note: Flow values are presented as minimum/rated/maximum operating points. The (I) suffix denotes high-flow variants. 6-pole (970 RPM) models are available for large-flow, low-head applications where reduced speed improves efficiency and NPSH performance.
5. Structural Design & Material Engineering
5.1 Pump Casing & Impeller Materials
| Component | Standard Material | Optional Material | Application Driver |
|---|---|---|---|
| Pump Casing | Cast Iron (HT200) | Stainless Steel, Ductile Iron | Corrosion resistance, pressure rating |
| Impeller | Cast Iron (HT200) | Bronze, Stainless Steel | Seawater, chemical compatibility |
| Shaft | 45# Carbon Steel | 2Cr13, 304/316 SS | Corrosion resistance, strength |
| Wear Ring | Stainless Steel (2Cr13) | Bronze, Hastelloy | Abrasion resistance |
5.2 Vertical Configuration Advantages
- Space Efficiency: Minimal footprint (0.2–0.4 m²); vertical integration reduces horizontal space requirements by 60–70%.
- Installation & Maintenance: No field alignment required; top-access service allows mechanical seal and impeller replacement without disturbing piping.
- Operational Stability: Balanced rotor design with short shaft overhang minimizes deflection, resulting in low vibration and quiet operation.
5.3 Mechanical Seal System
| Seal Component | Standard Configuration | High-Duty Configuration |
|---|---|---|
| Seal Faces | Carbon vs. Ceramic | Silicon Carbide (SiC) vs. SiC |
| Secondary Seal | NBR O-rings | Viton (FKM) or EPDM |
| Spring | AISI 304 Stainless Steel | Hastelloy C |
| Cooling | Internal recirculation | External flush (for hot water >80°C) |
6. Motor Engineering & Drive Options
6.1 Standard Motor Configuration
| Parameter | Specification |
|---|---|
| Motor Type | TEFC three-phase induction motor |
| Efficiency Class | IE2 (standard); IE3 (premium efficiency option) |
| Poles / Speed | 2-pole (2900 RPM), 4-pole (1450 RPM), or 6-pole (970 RPM) |
| Insulation / Protection | Class F (155°C) / IP54 (standard), IP55 (optional) |
| Mounting | B5 (flange mounted) vertical |
6.2 Variable Frequency Drive (VFD) Compatibility
The ISG series is fully compatible with VFD operation for energy-efficient flow control:
Q2 = Q1 × (f2 / f1) | H2 = H1 × (f2 / f1)2 | P2 = P1 × (f2 / f1)3
Energy Savings Example: For a high-rise building water supply system operating at 75% of design flow, P75% = 37 × (0.75)3 = 15.6 kW. Energy savings during part-load = 57.8% compared to constant-speed operation with throttling control.
7. Application Engineering & Selection Guidelines
7.1 Duty Point Selection & NPSH
The optimal pump selection positions the system operating point at or near the Best Efficiency Point (BEP):
Qoperating ≈ 0.8 × QBEP to 1.1 × QBEP
NPSHa = (Pinlet - Pvapor) / (ρg) + Hstatic - Hfriction,suction ≥ NPSHr + 0.5 m
7.2 Typical Application Scenarios
| Application | Recommended Model Range | Key Selection Criteria |
|---|---|---|
| High-rise building water supply | ISG80-160 to ISG150-315 | High head for vertical lift; constant pressure with VFD; compact footprint |
| HVAC chilled/hot water | ISG50-125 to ISG200-400(I) | Energy-efficient VFD operation; quiet operation; 4-pole for large flows |
| Industrial and urban water supply | ISG100-200 to ISG300-380 | Large flow; moderate head; reliability; redundancy |
| Fire-fighting pressurization | ISG80-250 to ISG125-315 | High head for sprinkler pressure; automatic start; standby duty |
| Boiler hot water circulation | ISG50-160 to ISG100-200 | High temperature capability (ISG-R); reliable bearing system |
| Petroleum & chemical transfer | ISG-YG / ISG-IH variants | Chemical compatibility; explosion-proof (ISG-EX); corrosion resistance |
8. Installation, Operation & Maintenance
8.1 Installation Requirements
| Parameter | Requirement |
|---|---|
| Foundation | Rigid, level concrete pad or steel frame; anchor bolts for vibration isolation |
| Piping Support | Pump can be supported by piping for small models (≤DN50); independent supports required for DN65+ |
| Vertical Alignment | Ensure pump is plumb within 0.5° to prevent bearing misalignment |
| Outdoor Installation | Provide protective canopy or enclosure; ensure IP rating matches environment |
8.2 Maintenance Protocol
| Inspection Item | Frequency | Action |
|---|---|---|
| Mechanical seal leakage | Monthly | Replace if drip rate exceeds 5 drops/minute |
| Bearing temperature | Monthly | Investigate if >80°C or ΔT >15°C from ambient |
| Vibration analysis | Quarterly | ISO 10816 criteria; velocity >4.5 mm/s RMS requires investigation |
| Vertical alignment | Annually | Verify plumbness; correct if foundation settlement detected |
| Cooling system (ISG-GR) | Quarterly | Verify coolant flow and temperature |
9. Ordering Information & Custom Engineering
9.1 Required Specification Data
| Parameter | Example Value |
|---|---|
| Pump Model | ISG100-200(I) |
| Fluid Type | Chilled water / Hot water / Process water |
| Flow Rate (Q) | 160 m³/h |
| Total Dynamic Head (H) | 50 m |
| Fluid Temperature | ≤ 80°C (standard) / ≤ 240°C (high-temp) |
| Material Specification | Standard cast iron |
| Connection Type | Flanged PN16, DN100 |
9.2 Custom Engineering Options
- ISG-H / ISG-IH: Full stainless steel or alloy construction for chemical/seawater applications
- ISG-R / ISG-GR: Cooling system and high-temperature seals for service up to +120°C or +240°C
- ISG-YG / ISG-EX: Oil pump or explosion-proof variants for hazardous areas
- Special voltages/frequencies: 220 V, 415 V, 460 V; 60 Hz designs for export markets
- Double mechanical seal: Barrier fluid system for hazardous or crystallizing fluids
10. Why Choose ISG Series for Your Fluid Circulation Needs?
| Engineering Criterion | ISG Series Advantage |
|---|---|
| Space Efficiency | Vertical inline design reduces footprint by 60–70% vs. horizontal pumps |
| Installation Simplicity | Valve-like installation in pipeline; no directional changes; minimal civil works |
| Maintenance Accessibility | Top-access service; union seat removal without pipeline disassembly |
| Energy Savings | VFD-compatible for variable-flow systems; affinity law cubic power reduction |
| Operational Stability | Direct-drive impeller on motor shaft; balanced rotor; low vibration and noise |
| Temperature Range | Standard -15°C to +80°C; ISG-R to +120°C; ISG-GR to +240°C |
| Versatility | Flow range 1.5–6000 m³/h; head range 5–153.6 m; covers all building services |
| Global Compliance | ISO 2858, JB/T 53058-90 certified; CE marking available |
Get a Free Custom Quote for ISG Vertical Inline Pumps
Choose TITECHO's ISG series for space-saving vertical design, superior hydraulic efficiency, and reliable fluid circulation. Our team responds within 24 hours!
📞 +86 13305761511
✉️ info@cntecho.com
💬 WhatsApp: Nancy / Jahor
Related News
LATEST
INFORMATION
Get the latest product information of the company
NAVIGATION
PRODUCTS
CONTACT US
Telephone: +86 13305761511
Email: info@cntecho.com
Add: RM. 602, BUILDING B, NO.1551 SHUANGSHUI RD., LUQIAO DIST., TAIZHOU CITY, ZHEJIANG, CHINA
Copyright © 2026 TECHO ELECTRICAL & MECHANICAL (TAIZHOU) CO., LTD. All Rights Reserved.