TECHO ELECTRICAL & MECHANICAL

BLOG

Jun 25,2026

ISG Vertical Inline Centrifugal Pump for HVAC & Water Supply

ISG vertical inline centrifugal pumps provide high‑efficiency water circulation for HVAC, building supply, industrial processes, and municipal systems with a compact, space‑saving design.


Introduction: The Vertical Inline Advantage in Modern Pumping Infrastructure

The ISG series vertical inline centrifugal pump is a single-stage, single-suction pump engineered for applications where horizontal floor space is at a premium and vertical integration into piping systems is preferred. Unlike horizontal pumps that require significant footprint area, the ISG series features a true vertical inline design with suction and discharge flanges aligned on the same vertical centerline and sharing identical nominal diameters. This configuration enables the pump to be installed directly in the pipeline like a valve, dramatically reducing both installation footprint and structural support requirements.

Designed in accordance with ISO 2858 and JB/T 53058-90 standards, the ISG series represents the second generation of high-efficiency, energy-saving vertical pipeline pumps. With flow capacities from 1.5 m³/h to 6000 m³/h, heads up to 153.6 meters, and power ratings from 0.18 kW to 110 kW, the ISG series addresses the complete spectrum of industrial and urban water supply, high-rise building pressurization, HVAC circulation, fire-fighting systems, and long-distance water transfer applications.

1. Vertical Inline Pump Technology: Design Principles

1.1 Valve-Like Installation Concept

The defining engineering characteristic of the ISG series is its vertical inline configuration with identical inlet and outlet diameters on the same centerline:

  • Compact footprint: The pump occupies minimal floor space, with the motor mounted vertically above the pump casing
  • Piping simplification: Straight-through alignment eliminates the need for suction elbows, discharge elbows, and directional changes
  • Structural efficiency: The pump can be supported by the piping itself or on a small foundation pad, reducing civil engineering costs
  • Outdoor capability: With the addition of a protective canopy, the ISG series can operate in exposed environments without dedicated pump houses

Space Comparison: For a DN100 pump installation, the ISG series requires approximately 0.25 m² of floor space versus 0.8–1.2 m² for an equivalent horizontal end-suction pump with suction elbow and discharge piping. This represents a 70–80% footprint reduction — critical in congested mechanical rooms and equipment galleries.

1.2 Impeller-on-Motor-Shaft Architecture

The ISG series employs a direct-drive design with the impeller mounted directly on the motor's extended shaft, eliminating coupling and separate bearing housing, reducing overall height by 20–30%, and minimizing torsional oscillation for low vibration and quiet operation.

The axial load generated by the single-suction impeller is calculated as:

Faxial = ΔP × Aimpeller eye

Where: 
Faxial = Axial thrust force (N) 
ΔP = Pressure differential across impeller (Pa) 
Aimpeller eye = Cross-sectional area of impeller eye (m²) 
The motor thrust bearing is sized to absorb this load with a minimum safety factor of 2.0.

2. Hydraulic Fundamentals: Pump Performance Equations

2.1 Hydraulic Power & Pump Efficiency

Phydraulic = (ρ × g × Q × H) / (1000 × ηp)

Practical Calculation Example: 
For an ISG80-200 pump operating at rated conditions (Q=50 m³/h = 0.0139 m³/s, H=50 m), with ηp = 0.76: 
Phydraulic = (1000 × 9.81 × 0.0139 × 50) / (1000 × 0.76) ≈ 8.97 kW 
The installed 15 kW motor provides adequate service factor for startup torque, wear-induced efficiency degradation, and voltage fluctuation tolerance.

2.2 System Head Calculation

Htotal = Hstatic + Hfriction + Hvelocity

Darcy-Weisbach Friction Loss:

Hf = f × (L / D) × (v2 / (2g))

Velocity Head:

Hv = v2 / (2g)

For ISG series applications, recommended pipe velocities range from 1.0 to 2.5 m/s on the discharge side and 0.8 to 1.8 m/s on the suction side to prevent cavitation and ensure efficient operation.

2.3 Specific Speed & Impeller Classification

Ns = n × √Q / H0.75

For the ISG100-250 pump (n=2900 RPM, Q=100 m³/h = 0.0278 m³/s, H=80 m): 
Ns = (2900 × √0.0278) / 800.75 ≈ 1810, indicating a radial-to-mixed-flow impeller design optimized for moderate flow and moderate-to-high head applications.

3. ISG Series Technical Specifications

3.1 General Operating Parameters

ParameterSpecification
Pump TypeSingle-stage single-suction vertical inline centrifugal pump
Standard ComplianceISO 2858, JB/T 53058-90
Power Range0.18 kW – 110 kW
Flow Range1.5 m³/h – 6000 m³/h
Head Range5 m – 153.6 m
Voltage / FrequencyThree-phase 380 V / 50 Hz (standard); optional voltages
Rotational Speed1450 RPM (4-pole); 2900 RPM (2-pole); 970 RPM (6-pole)
Medium Temperature-15°C to +80°C (standard); up to +240°C (high-temp variant)
Max Working Pressure1.6 MPa (16 bar)
Inlet/Outlet ConnectionFlanged (PN16); threaded (for small models)

3.2 Model Nomenclature

Example: ISG80-200 
ISG: ISG series vertical inline centrifugal pump 
80: Inlet/outlet nominal diameter = 80 mm (3 inch) 
200: Impeller nominal diameter = 200 mm

Variant Codes:

  • A / B suffix: Trimmed impeller for reduced head at same flow
  • (I) suffix: High-flow variant with enlarged impeller eye
  • ISG-H / ISG-IH: Corrosion-resistant / chemical variants
  • ISG-R / ISG-GR: Hot water / high-temperature variants
  • ISG-YG / ISG-EX: Oil pump / explosion-proof variants

4. Performance Data Tables

4.1 Small-Duty Range: DN15 – DN32 (0.18 kW – 4.0 kW)

ModelDN (mm)Flow Q (m³/h)Head H (m)η (%)RPMPower (kW)NPSHr (m)
ISG15-80151.1 / 1.5 / 2.08.5 / 8 / 726 / 34 / 3428000.182.3
ISG25-125252.8 / 4.0 / 5.220.6 / 20 / 1828 / 36 / 3529000.752.3
ISG32-100(I)324.4 / 6.3 / 8.313.2 / 12.5 / 11.348 / 54 / 5329000.752.0
ISG32-200(I)324.4 / 6.3 / 8.350.5 / 50 / 4826 / 33 / 3529004.02.0

4.2 Medium-Duty Range: DN40 – DN65 (0.55 kW – 15 kW)

ModelDN (mm)Flow Q (m³/h)Head H (m)η (%)RPMPower (kW)NPSHr (m)
ISG40-160404.4 / 6.3 / 8.333 / 32 / 3035 / 40 / 4029002.22.3
ISG50-200508.3 / 12.5 / 16.350 / 48 / 4632 / 40 / 4229005.52.3
ISG65-1606517.5 / 25 / 32.535 / 32 / 2848 / 56 / 5529005.52.5
ISG65-2506517.5 / 25 / 32.582 / 80 / 7438 / 48 / 502900152.5

4.3 Large-Duty Range: DN80 – DN100 (5.5 kW – 90 kW)

ModelDN (mm)Flow Q (m³/h)Head H (m)η (%)RPMPower (kW)NPSHr (m)
ISG80-160(I)8070 / 100 / 13036.5 / 32 / 2470 / 76 / 652900154.5
ISG100-160(I)10096 / 160 / 19236 / 32 / 2769 / 79 / 752900225.6
ISG100-250(I)10096 / 160 / 19283 / 80 / 7265 / 77 / 742900554.8
ISG100-35010060 / 100 / 120153.6 / 150 / 142.872 / 57 / 742900904.0

4.4 Heavy-Duty Range: DN125 – DN300 (11 kW – 132 kW)

ModelDN (mm)Flow Q (m³/h)Head H (m)η (%)RPMPower (kW)NPSHr (m)
ISG125-25012596 / 160 / 19287 / 80 / 73752900555.0
ISG150-315150140 / 200 / 26033.8 / 32 / 2870 / 78 / 781450302.5
ISG200-315(I)200280 / 400 / 52036 / 32 / 2673 / 80 / 751450554.0
ISG300-380300480 / 720 / 90048 / 44 / 34849701325.0

Note: Flow values are presented as minimum/rated/maximum operating points. The (I) suffix denotes high-flow variants. 6-pole (970 RPM) models are available for large-flow, low-head applications where reduced speed improves efficiency and NPSH performance.

5. Structural Design & Material Engineering

5.1 Pump Casing & Impeller Materials

ComponentStandard MaterialOptional MaterialApplication Driver
Pump CasingCast Iron (HT200)Stainless Steel, Ductile IronCorrosion resistance, pressure rating
ImpellerCast Iron (HT200)Bronze, Stainless SteelSeawater, chemical compatibility
Shaft45# Carbon Steel2Cr13, 304/316 SSCorrosion resistance, strength
Wear RingStainless Steel (2Cr13)Bronze, HastelloyAbrasion resistance

5.2 Vertical Configuration Advantages

  • Space Efficiency: Minimal footprint (0.2–0.4 m²); vertical integration reduces horizontal space requirements by 60–70%.
  • Installation & Maintenance: No field alignment required; top-access service allows mechanical seal and impeller replacement without disturbing piping.
  • Operational Stability: Balanced rotor design with short shaft overhang minimizes deflection, resulting in low vibration and quiet operation.

5.3 Mechanical Seal System

Seal ComponentStandard ConfigurationHigh-Duty Configuration
Seal FacesCarbon vs. CeramicSilicon Carbide (SiC) vs. SiC
Secondary SealNBR O-ringsViton (FKM) or EPDM
SpringAISI 304 Stainless SteelHastelloy C
CoolingInternal recirculationExternal flush (for hot water >80°C)

6. Motor Engineering & Drive Options

6.1 Standard Motor Configuration

ParameterSpecification
Motor TypeTEFC three-phase induction motor
Efficiency ClassIE2 (standard); IE3 (premium efficiency option)
Poles / Speed2-pole (2900 RPM), 4-pole (1450 RPM), or 6-pole (970 RPM)
Insulation / ProtectionClass F (155°C) / IP54 (standard), IP55 (optional)
MountingB5 (flange mounted) vertical

6.2 Variable Frequency Drive (VFD) Compatibility

The ISG series is fully compatible with VFD operation for energy-efficient flow control:

Q2 = Q1 × (f2 / f1)   |   H2 = H1 × (f2 / f1)2   |   P2 = P1 × (f2 / f1)3

Energy Savings Example: For a high-rise building water supply system operating at 75% of design flow, P75% = 37 × (0.75)3 = 15.6 kW. Energy savings during part-load = 57.8% compared to constant-speed operation with throttling control.

7. Application Engineering & Selection Guidelines

7.1 Duty Point Selection & NPSH

The optimal pump selection positions the system operating point at or near the Best Efficiency Point (BEP): 
Qoperating ≈ 0.8 × QBEP to 1.1 × QBEP

NPSHa = (Pinlet - Pvapor) / (ρg) + Hstatic - Hfriction,suction ≥ NPSHr + 0.5 m

7.2 Typical Application Scenarios

ApplicationRecommended Model RangeKey Selection Criteria
High-rise building water supplyISG80-160 to ISG150-315High head for vertical lift; constant pressure with VFD; compact footprint
HVAC chilled/hot waterISG50-125 to ISG200-400(I)Energy-efficient VFD operation; quiet operation; 4-pole for large flows
Industrial and urban water supplyISG100-200 to ISG300-380Large flow; moderate head; reliability; redundancy
Fire-fighting pressurizationISG80-250 to ISG125-315High head for sprinkler pressure; automatic start; standby duty
Boiler hot water circulationISG50-160 to ISG100-200High temperature capability (ISG-R); reliable bearing system
Petroleum & chemical transferISG-YG / ISG-IH variantsChemical compatibility; explosion-proof (ISG-EX); corrosion resistance

8. Installation, Operation & Maintenance

8.1 Installation Requirements

ParameterRequirement
FoundationRigid, level concrete pad or steel frame; anchor bolts for vibration isolation
Piping SupportPump can be supported by piping for small models (≤DN50); independent supports required for DN65+
Vertical AlignmentEnsure pump is plumb within 0.5° to prevent bearing misalignment
Outdoor InstallationProvide protective canopy or enclosure; ensure IP rating matches environment

8.2 Maintenance Protocol

Inspection ItemFrequencyAction
Mechanical seal leakageMonthlyReplace if drip rate exceeds 5 drops/minute
Bearing temperatureMonthlyInvestigate if >80°C or ΔT >15°C from ambient
Vibration analysisQuarterlyISO 10816 criteria; velocity >4.5 mm/s RMS requires investigation
Vertical alignmentAnnuallyVerify plumbness; correct if foundation settlement detected
Cooling system (ISG-GR)QuarterlyVerify coolant flow and temperature

9. Ordering Information & Custom Engineering

9.1 Required Specification Data

ParameterExample Value
Pump ModelISG100-200(I)
Fluid TypeChilled water / Hot water / Process water
Flow Rate (Q)160 m³/h
Total Dynamic Head (H)50 m
Fluid Temperature≤ 80°C (standard) / ≤ 240°C (high-temp)
Material SpecificationStandard cast iron
Connection TypeFlanged PN16, DN100

9.2 Custom Engineering Options

  • ISG-H / ISG-IH: Full stainless steel or alloy construction for chemical/seawater applications
  • ISG-R / ISG-GR: Cooling system and high-temperature seals for service up to +120°C or +240°C
  • ISG-YG / ISG-EX: Oil pump or explosion-proof variants for hazardous areas
  • Special voltages/frequencies: 220 V, 415 V, 460 V; 60 Hz designs for export markets
  • Double mechanical seal: Barrier fluid system for hazardous or crystallizing fluids

10. Why Choose ISG Series for Your Fluid Circulation Needs?

Engineering CriterionISG Series Advantage
Space EfficiencyVertical inline design reduces footprint by 60–70% vs. horizontal pumps
Installation SimplicityValve-like installation in pipeline; no directional changes; minimal civil works
Maintenance AccessibilityTop-access service; union seat removal without pipeline disassembly
Energy SavingsVFD-compatible for variable-flow systems; affinity law cubic power reduction
Operational StabilityDirect-drive impeller on motor shaft; balanced rotor; low vibration and noise
Temperature RangeStandard -15°C to +80°C; ISG-R to +120°C; ISG-GR to +240°C
VersatilityFlow range 1.5–6000 m³/h; head range 5–153.6 m; covers all building services
Global ComplianceISO 2858, JB/T 53058-90 certified; CE marking available

Get a Free Custom Quote for ISG Vertical Inline Pumps

Choose TITECHO's ISG series for space-saving vertical design, superior hydraulic efficiency, and reliable fluid circulation. Our team responds within 24 hours!

📞 +86 13305761511

✉️ info@cntecho.com

💬 WhatsApp: Nancy / Jahor

Get Free Custom Quote Now → 

LATEST

INFORMATION

Get the latest product information of the company

%{tishi_zhanwei}%

CONTACT US

Telephone: +86 13305761511
Email: info@cntecho.com

Add: RM. 602, BUILDING B, NO.1551 SHUANGSHUI RD., LUQIAO DIST., TAIZHOU CITY, ZHEJIANG, CHINA

 


Copyright © 2026 TECHO ELECTRICAL & MECHANICAL (TAIZHOU) CO., LTD. All Rights Reserved.

Business License

Search for the product name you want to search

TECHO ELECTRICAL & MECHANICAL

%{tishi_zhanwei}%