Introduction

An electrically excited synchronous motor is an AC motor whose rotor magnetic field is produced by direct current (DC) flowing in a rotor field winding. The stator creates a rotating magnetic field, and the rotor runs in step with it once the motor is synchronized. This design is also called a wound-field synchronous motor, distinguishing it from a permanent magnet synchronous motor, whose rotor field comes from permanent magnets. [1] [2]

Electrically excited synchronous motors are used in applications that need steady operating speed, high power, or control of reactive power and power factor. Their operation depends on an excitation system as well as the stator supply, so the motor, exciter, starter, and protection need to be considered together. [2] [3]

Key Takeaways

  • DC excitation in the rotor winding establishes the rotor’s magnetic field. [1] [2]
  • Once synchronized, the rotor turns at the same average speed as the stator’s rotating magnetic field. [1]
  • Changing field current affects the motor’s reactive-power exchange and power factor, within the motor’s operating limits. [3]
  • Large synchronous motors may start using a damper winding or a controlled starting system, then receive field excitation as they approach synchronous speed. [2]
  • Excitation can be supplied through brushes and collector rings or by a brushless exciter. [2]

What does “electrically excited” mean?

The stator of a synchronous motor is supplied with AC and produces a rotating magnetic field. The rotor carries a field winding. When DC is passed through that winding, it creates north and south magnetic poles on the rotor. The interaction between the rotor poles and the stator’s rotating field produces torque. [1] [2]

“Electrically excited” describes how the rotor field is created. In a permanent magnet synchronous motor (PMSM), permanent magnets provide the rotor field. In a wound-field machine, a controllable DC current in the rotor winding provides it. This gives the machine an adjustable excitation level, but it also means the motor needs a field supply and an excitation system. [1] [2]

How does a synchronous motor maintain speed?

The speed of the stator’s rotating magnetic field is set by supply frequency and the number of poles:

Synchronous speed (r/min) = 120 × frequency (Hz) ÷ number of poles

At 50 Hz, a four-pole motor has a synchronous speed of 1,500 r/min. At 60 Hz, the same pole count gives 1,800 r/min. Once the rotor has pulled into synchronism, it rotates at this synchronous speed under steady conditions. If the mechanical load changes within the motor’s capability, the rotor’s torque angle changes to produce the required torque, rather than the speed falling in the same way it does for an induction motor. [1] [3]

A fixed-frequency synchronous motor therefore runs at a speed determined by the supply frequency and pole count. Where a process requires a range of speeds, a suitable variable-frequency drive can control the supply frequency. The motor and converter must be designed and configured as a compatible drive system. [2]

How is the rotor field supplied?

Brushes and collector rings

In a static excitation arrangement, a DC source supplies the rotor field through brushes that contact collector rings on the rotating shaft. This provides a direct electrical path to the rotor winding. Brush and collector-ring condition is part of the machine’s inspection and maintenance requirements. [2]

Brushless excitation

A brushless system uses a rotating exciter and rectifier assembly to provide DC to the main rotor field. Because the field current is transferred without conventional brushes and collector rings, the arrangement reduces some brush-related maintenance tasks. The actual system design and maintenance schedule remain equipment-specific. [2]

Both approaches control the strength of the rotor field by adjusting excitation current. The exciter, control equipment, and protective functions must be matched to the synchronous motor and its operating mode. [2]

Why does excitation affect power factor?

The stator current supplies both the active power associated with mechanical output and reactive power associated with the magnetic fields. Adjusting rotor field current changes the magnetic relationship between the stator and rotor fields and therefore changes the motor’s reactive-power exchange with the electrical system. [3]

At a given load, a synchronous motor can be operated near unity power factor by setting the field excitation appropriately. Underexcited operation generally draws reactive power and has a lagging power factor. Overexcited operation can supply reactive power to the system and operate at a leading power factor. These operating points are limited by the motor’s stator and rotor thermal ratings, excitation limits, and the needs of the electrical system. [3]

This capability is why synchronous motors can be used for more than mechanical drive. When correctly controlled and integrated, they can contribute to power-factor management. They do not automatically correct power factor under every condition, and excitation should be managed according to system requirements and machine limits. [2] [3]

How are synchronous motors started?

A conventional synchronous motor connected to a fixed-frequency supply does not generally start by itself as a synchronous rotor. It needs a method to accelerate the rotor and bring it into synchronism. Depending on the motor and application, starting may use a damper or amortisseur winding, a variable-frequency drive, a separate starting motor, or another engineered starting arrangement. [2]

In one common approach, the motor accelerates asynchronously with the aid of a damper winding. When it reaches a suitable speed, the control system applies field excitation and synchronizes the rotor with the rotating stator field. Large motors may use dedicated synchronization controls to manage field application and monitor the start. [2]

The correct method depends on the motor’s construction, load inertia, starting torque, supply-network capacity, and process requirements. The motor documentation and starting-system design specify the permitted procedure. [2]

Typical applications

Synchronous motors are used for compressors, pumps, fans, extruders, mills, refiners, and other large industrial loads. They are found in sectors such as oil and gas, metals and mining, pulp and paper, marine, water and wastewater, and power utilities. Both fixed-speed and variable-speed synchronous drives are used, depending on the process. [2] [4]

Their use is particularly relevant where the application benefits from synchronous speed, high power, or adjustable power factor. These characteristics do not make the motor a universal choice: starting method, excitation equipment, drive requirements, size, installation, and maintenance all factor into the system decision.

Electrically excited synchronous motor vs. PMSM

Both motor types are synchronous AC machines. The key distinction is how the rotor field is created. An electrically excited synchronous motor uses a rotor winding supplied with DC, while a PMSM uses permanent magnets embedded in or attached to the rotor. [1]

The wound-field design allows the rotor excitation to be adjusted during operation, which can support reactive-power and power-factor control. A PMSM does not need a rotor field winding or a separate field-excitation supply, but its magnetic field is set by the permanent magnets and cannot be reduced by simply lowering a field current. Both types require suitable control and protection for their specific motor design. [1] [2]

Frequently asked questions

1 What is an electrically excited synchronous motor?

It is a synchronous AC motor in which DC current in a rotor field winding creates the rotor’s magnetic field. Once synchronized with the stator’s rotating magnetic field, it runs at synchronous speed. [1]

2 How does excitation control a synchronous motor’s power factor?

Changing the rotor field current changes the motor’s reactive-power exchange with the supply. Underexcited operation generally produces a lagging power factor, while overexcited operation can produce a leading power factor. The allowed range depends on the motor and system limits. [3]

3 Does a synchronous motor need brushes?

Not always. Some machines feed DC to the rotor through brushes and collector rings, while brushless excitation systems use a rotating exciter and rectifier to supply the rotor field. [2]

4 Can an electrically excited synchronous motor start directly from rest?

A conventional synchronous motor on a fixed-frequency supply generally needs a starting method to accelerate and synchronize the rotor. Common arrangements include damper-winding starting and converter-based starting, but the specific method depends on the motor and application. [2]

5 What is the difference between a wound-field synchronous motor and a PMSM?

A wound-field synchronous motor uses DC in a rotor winding to create its magnetic field. A PMSM uses permanent magnets in the rotor. The wound-field motor can adjust excitation current; a PMSM does not use a separate rotor field-current supply. [1] [2]

References

LATEST

INFORMATION

Get the latest product information of the company

%{tishi_zhanwei}%

CONTACT US

Telephone: +86 13305761511
Email: info@cntecho.com

Add: RM. 602, BUILDING B, NO.1551 SHUANGSHUI RD., LUQIAO DIST., TAIZHOU CITY, ZHEJIANG, CHINA

 


Copyright © 2026 TECHO ELECTRICAL & MECHANICAL (TAIZHOU) CO., LTD. All Rights Reserved.

Business License

Search for the product name you want to search

TECHO ELECTRICAL & MECHANICAL

%{tishi_zhanwei}%