Deep Well Pumps – Submersible Borehole Pump Engineering Guide
A complete engineering guide to deep well pumps, covering multistage hydraulics, TDH calculation, borehole sizing, cable selection, cooling, materials, and installation best practices.
What Is a Deep Well Pump?
A deep well pump is a submersible multistage centrifugal pump designed to extract groundwater from boreholes where the water table lies beyond the practical suction limit of surface pumps. Unlike jet pumps that pull water upward (limited to approximately 8 meters of suction lift), submersible pumps push water from below — with no theoretical depth limit, operating reliably at depths exceeding 500 meters.
The pump unit consists of two hermetically sealed components: a hydraulic section (multiple impeller stages stacked in series) and a submersible motor (oil-filled or water-filled, cooled by the surrounding well water). The entire assembly is suspended in the borehole on a riser pipe, with power supplied through a specialized submersible cable.
The Multistage Centrifugal Principle
How Pressure Builds Stage by Stage
Each impeller stage adds incremental pressure to the fluid. The total head developed is approximately:
Htotal = Nstages × Hper stage
| Symbol | Description | Unit |
|---|---|---|
| Htotal | Total pump head | m |
| Nstages | Number of impeller stages | — |
| Hper stage | Head per stage at operating point | m |
Typical Stage Performance (4-inch pump)
| Impeller Design | Head per Stage @ BEP | Flow Range |
|---|---|---|
| Standard radial | 8–15 m | 1–10 m³/h |
| Semi-open | 6–12 m | 5–20 m³/h |
| High-head closed | 12–20 m | 1–8 m³/h |
Example: A 25-stage pump with 10 m per stage delivers 250 m total head — sufficient for a 200-meter well with 50 meters of residual pressure for distribution.
Pump Types by Borehole Diameter
| Pump Series | Outer Diameter | Fits Casing | Max Flow | Typical Depth | Best Applications |
|---|---|---|---|---|---|
| 3-inch (75 mm) | 74 mm | 3.5"+ | 1–3 m³/h | 30–150 m | Domestic, small gardens |
| 4-inch (100 mm) | 95–98 mm | 5"–6" | 1–25 m³/h | 50–300 m | Homes, small communities, irrigation |
| 6-inch (150 mm) | 143–146 mm | 8"+ | 5–80 m³/h | 50–500 m | Municipal supply, large irrigation |
| 8-inch (200 mm) | 190–195 mm | 10"+ | 20–200 m³/h | 50–400 m | Industrial, municipal |
| 10-inch (250 mm) | 240–245 mm | 12"+ | 50–400 m³/h | 50–300 m | Large municipal, mining |
| 12-inch (300 mm) | 290–295 mm | 14"+ | 100–600 m³/h | 50–250 m | Bulk water transfer |
Critical Sizing Rule: The pump must fit inside the casing with adequate clearance for the power cable, cable guard, and safe lowering. A tight casing increases the risk of cable abrasion, pump jamming, and poor motor cooling. Always provide the casing internal diameter, not just the nominal well size, when requesting a quotation.
Total Dynamic Head (TDH): The Core Calculation
The single most important parameter for deep well pump selection is Total Dynamic Head — the total resistance the pump must overcome. It is not the well depth.
TDH = Hdynamic + Helevation + Hpressure + Hfriction
Component Breakdown
| Component | Symbol | Description | How to Determine |
|---|---|---|---|
| Dynamic water level | Hdynamic | Water level during pumping | Pump test or specific yield curve |
| Elevation lift | Helevation | Height from ground to discharge point | Site survey |
| Pressure head | Hpressure | Required outlet pressure | Application requirement |
| Friction losses | Hfriction | Pipe, valves, fittings resistance | Darcy-Weisbach or Hazen-Williams |
Pressure-to-Head Conversion
Hm = (Pbar × 100,000) / (ρ × g) = Pbar × 10.2
| Required Pressure | Equivalent Head |
|---|---|
| 1 bar | 10.2 m |
| 2 bar | 20.4 m |
| 3 bar | 30.6 m |
| 4 bar | 40.8 m |
| 5 bar | 51.0 m |
Complete Sizing Example: Industrial Borehole
Project: Water supply from borehole to elevated storage tank for a small community
Input Data
| Parameter | Value |
|---|---|
| Required flow rate | 40 m³/h |
| Static water level | 30 m below ground |
| Drawdown at 40 m³/h | 10 m (from specific yield test) |
| Dynamic water level | 30 + 10 = 40 m |
| Tank elevation above ground | 15 m |
| Horizontal pipe distance | 100 m |
| Pipe material | Steel, DN80 |
| Discharge pressure | 0 bar (gravity feed to tank) |
| Valves & fittings | 1 check valve, 3 × 90° elbows |
Step-by-Step Calculation
Step 1: Determine Flow Velocity
v = Q / A = (40/3600) / (π × 0.08² / 4) ≈ 2.21 m/s
Design Check: Velocity of 2.21 m/s is within the recommended 1.5–3.0 m/s range for steel discharge pipes.
Step 2: Calculate Friction Losses
hf = 8.2 m/100m × (140m / 100) = 11.5 m
Local losses: Check valve (0.09 m) + 3 elbows (0.21 m) = 0.30 m
Hfriction = 11.5 + 0.30 = 11.8 m
Step 3 & 4: Calculate Static Head & Total Dynamic Head
Hstatic = Hdynamic + Helevation = 40 + 15 = 55 m
TDH = Hstatic + Hfriction = 55 + 11.8 = 66.8 m
Step 5: Select Pump from Catalog
From manufacturer curves, select a pump where the duty point (40 m³/h @ 66.8 m) falls within the preferred operating range of 70–120% of nominal capacity and near the Best Efficiency Point (BEP).
Selected: CRS 8-40/6-15 pump — 40 m³/h @ 90 m head (provides margin for future demand increase and wear).
Pump Selection Example: Domestic Deep Well
Project: 2-story house with garden, water at 70 m depth
| Parameter | Value |
|---|---|
| Bathrooms / Storeys | 2 / 2 |
| Static / Dynamic water level | 70 m / 75 m (5m drawdown) |
| Highest fixture elevation | 6 m above ground |
| System pressure loss | 20% of geometric head |
| Required residual pressure | 2 bar (20.4 m) |
Hgeo = 70 + (3 × 2) = 76 m
Hsystem = 20% × 76 = 15.2 m
TDH = 76 + 15.2 + 20.4 = 111.6 m ≈ 112 m
From flow rate tables for 2 bathrooms: Q = 1.7 m³/h. Selected: 4-inch submersible pump, 1.7 m³/h @ 112 m head (e.g., S4C-25 model).
Friction Loss Reference Tables
Steel Pipe Head Loss (m per 100 m)
| Flow (m³/h) | DN50 | DN65 | DN80 | DN100 | DN125 |
|---|---|---|---|---|---|
| 10 | 6.5 | 2.1 | 0.7 | 0.2 | 0.1 |
| 20 | 23.8 | 7.6 | 2.5 | 0.8 | 0.3 |
| 30 | 51.2 | 16.3 | 5.4 | 1.7 | 0.6 |
| 40 | — | 28.2 | 9.3 | 2.9 | 1.1 |
| 50 | — | 43.4 | 14.3 | 4.5 | 1.7 |
Plastic Pipe (PE/HDPE) Head Loss (m per 100 m)
| Flow (m³/h) | d40 | d50 | d63 | d75 | d90 |
|---|---|---|---|---|---|
| 5 | 8.9 | 3.2 | 1.0 | 0.4 | 0.2 |
| 10 | 32.6 | 11.7 | 3.7 | 1.5 | 0.7 |
| 15 | 70.0 | 25.1 | 7.9 | 3.2 | 1.5 |
| 20 | — | 43.4 | 13.7 | 5.5 | 2.6 |
| 25 | — | — | 21.0 | 8.4 | 4.0 |
Design Guideline: Plastic pipes have significantly lower friction than steel. When replacing steel with plastic, you may reduce pipe diameter by one nominal size while maintaining equivalent or better hydraulic performance.
Cable Selection & Voltage Drop
Submersible motors require specialized cables rated for underwater installation. The cable must be sized to limit voltage drop to maximum 2% of nominal voltage.
ΔV = (√3 × I × L × cosϕ × Rcable) / 1000
| Motor Power | Nominal Current | Cable Length | Min. Cross-Section |
|---|---|---|---|
| 1.5 kW | 6.5 A | 100 m | 2.5 mm² |
| 3.0 kW | 12 A | 100 m | 4 mm² |
| 5.5 kW | 20 A | 150 m | 6 mm² |
| 7.5 kW | 27 A | 150 m | 10 mm² |
| 11 kW | 38 A | 200 m | 16 mm² |
| 15 kW | 50 A | 200 m | 25 mm² |
| 22 kW | 72 A | 250 m | 35 mm² |
Example: HMS Ciris 8-25-125 pump, 13 kW, 33 A nominal current, 160 m cable length → 25 mm² cross-section required.
Motor Cooling & Installation Depth
Critical Cooling Requirement
The submersible motor relies on water flow past its housing for cooling. Insufficient flow causes overheating and premature failure. Minimum flow velocity past motor: vmin = 0.2 m/s.
| Casing ID | Max Pump OD @ 40 m³/h | Max Pump OD @ 80 m³/h |
|---|---|---|
| 150 mm (6") | 143 mm | 138 mm |
| 200 mm (8") | 193 mm | 189 mm |
| 250 mm (10") | 243 mm | 240 mm |
Warning: Installing a pump in an oversized casing without a cooling shroud reduces water velocity past the motor, leading to overheating and shortened operational life.
Installation Depth Guidelines
| Parameter | Requirement |
|---|---|
| Pump intake strainer | Minimum 1 m below dynamic water level |
| Motor bottom | Minimum 1 m above well screen/filter |
| Total pump length | Must fit within straight section of casing |
| Cable routing | Alongside riser pipe, secured with cable guards |
Control, Protection & Materials
Essential Protection Functions
| Protection | Purpose | Implementation |
|---|---|---|
| Overload protection | Prevent motor burnout from excessive current | Thermal relays or electronic overload |
| Dry-run protection | Prevent operation without water | Float switch, level sensor, or current monitoring |
| Under/overvoltage | Protect motor from power quality issues | Voltage monitoring relay |
| Soft start | Eliminate water hammer, reduce starting current | Soft starter or VFD (recommended ≥7.5 kW) |
Material Selection for Water Chemistry
| Water Condition | Recommended Material | Avoid |
|---|---|---|
| Clean water, pH 6.5–8.5 | Stainless steel 304 | Cast iron (rust) |
| Aggressive water, high chlorides | Stainless steel 316 | 304 SS (pitting) |
| High TDS (>2000 ppm) | Duplex stainless steel | Standard 304/316 |
| High sand content (>50 g/m³) | Sand-resistant with floating impellers | Fixed impeller designs |
| Seawater / brackish | Duplex 2205 or titanium | All standard grades |
Common Selection & Installation Mistakes
| Mistake | Consequence | Prevention |
|---|---|---|
| Sizing by well depth alone | Undersized or oversized pump; energy waste | Always calculate TDH with dynamic water level |
| Exceeding well yield | Dry running, motor burnout, well damage | Pump flow ≤ tested well yield |
| Undersized discharge pipe | Excessive friction, reduced flow, high energy cost | Match pipe to pump outlet; velocity 1.5–3 m/s |
| Oversized casing without cooling shroud | Motor overheating, shortened life | Install cooling sleeve or select larger pump diameter |
| Undersized cable | Voltage drop, motor overheating, starting failure | Size cable for 2% max voltage drop |
| Installing pump below screen/filter | Sand ingress, rapid wear, motor damage | Maintain 1 m minimum clearance above screen |
Energy Optimization: Variable Speed Drives
Modern deep well pump systems increasingly incorporate Variable Frequency Drives (VFD) for energy savings and operational flexibility.
| Operating Condition | Fixed Speed | VFD-Controlled | Savings |
|---|---|---|---|
| Peak demand (100% flow) | 100% power | 100% power | 0% |
| Average demand (75% flow) | 100% power (throttled) | 42% power | 58% |
| Low demand (50% flow) | 100% power (bypassed) | 12.5% power | 87.5% |
VFD Benefits: Beyond energy savings, VFDs enable soft starting (eliminating water hammer), precise pressure control, automatic pump curve optimization, and integration with SCADA/remote monitoring systems.
Maintenance Schedule
| Task | Frequency | Purpose |
|---|---|---|
| Check control panel indicators | Monthly | Early fault detection |
| Measure operating current | Quarterly | Detect motor degradation |
| Inspect cable entry seal | Annually | Prevent water ingress |
| Pull pump for inspection | Every 3–5 years | Assess impeller wear, sand damage |
| Well yield test | Every 5 years | Verify aquifer performance |
Conclusion
Deep well pumps are the engineering solution to one of humanity's oldest challenges: accessing groundwater reliably and efficiently. The technology has evolved from simple piston pumps to sophisticated multistage centrifugal systems capable of delivering hundreds of cubic meters per hour from depths exceeding 500 meters.
The key to successful deep well pump installation lies not in selecting the most powerful pump, but in rigorous calculation of Total Dynamic Head, matching pump performance to well characteristics, proper material selection for water chemistry, and ensuring adequate motor cooling and electrical protection. For every meter of unnecessary head or every millimeter of undersized cable, the system pays a price in energy, reliability, and lifespan. The investment in accurate engineering at the selection stage pays dividends for decades of trouble-free operation.
Get Expert Deep Well Pump Consultation
Choose the right submersible pump system for your borehole project. Our technical team specializes in well pump sizing, TDH calculation, and material selection. Response within 24 hours!
📞 +86 13305761511
✉️ info@cntecho.com
💬 WhatsApp: Nancy / Jahor
Related News
LATEST
INFORMATION
Get the latest product information of the company
NAVIGATION
PRODUCTS
CONTACT US
Telephone: +86 13305761511
Email: info@cntecho.com
Add: RM. 602, BUILDING B, NO.1551 SHUANGSHUI RD., LUQIAO DIST., TAIZHOU CITY, ZHEJIANG, CHINA
Copyright © 2026 TECHO ELECTRICAL & MECHANICAL (TAIZHOU) CO., LTD. All Rights Reserved.