Deep Well Pumps – Submersible Borehole Pump Engineering Guide

A complete engineering guide to deep well pumps, covering multistage hydraulics, TDH calculation, borehole sizing, cable selection, cooling, materials, and installation best practices.


What Is a Deep Well Pump?

A deep well pump is a submersible multistage centrifugal pump designed to extract groundwater from boreholes where the water table lies beyond the practical suction limit of surface pumps. Unlike jet pumps that pull water upward (limited to approximately 8 meters of suction lift), submersible pumps push water from below — with no theoretical depth limit, operating reliably at depths exceeding 500 meters.

The pump unit consists of two hermetically sealed components: a hydraulic section (multiple impeller stages stacked in series) and a submersible motor (oil-filled or water-filled, cooled by the surrounding well water). The entire assembly is suspended in the borehole on a riser pipe, with power supplied through a specialized submersible cable.

The Multistage Centrifugal Principle

How Pressure Builds Stage by Stage

Each impeller stage adds incremental pressure to the fluid. The total head developed is approximately:

Htotal = Nstages × Hper stage

SymbolDescriptionUnit
HtotalTotal pump headm
NstagesNumber of impeller stages—
Hper stageHead per stage at operating pointm

Typical Stage Performance (4-inch pump)

Impeller DesignHead per Stage @ BEPFlow Range
Standard radial8–15 m1–10 m³/h
Semi-open6–12 m5–20 m³/h
High-head closed12–20 m1–8 m³/h

Example: A 25-stage pump with 10 m per stage delivers 250 m total head — sufficient for a 200-meter well with 50 meters of residual pressure for distribution.

Pump Types by Borehole Diameter

Pump SeriesOuter DiameterFits CasingMax FlowTypical DepthBest Applications
3-inch (75 mm)74 mm3.5"+1–3 m³/h30–150 mDomestic, small gardens
4-inch (100 mm)95–98 mm5"–6"1–25 m³/h50–300 mHomes, small communities, irrigation
6-inch (150 mm)143–146 mm8"+5–80 m³/h50–500 mMunicipal supply, large irrigation
8-inch (200 mm)190–195 mm10"+20–200 m³/h50–400 mIndustrial, municipal
10-inch (250 mm)240–245 mm12"+50–400 m³/h50–300 mLarge municipal, mining
12-inch (300 mm)290–295 mm14"+100–600 m³/h50–250 mBulk water transfer

Critical Sizing Rule: The pump must fit inside the casing with adequate clearance for the power cable, cable guard, and safe lowering. A tight casing increases the risk of cable abrasion, pump jamming, and poor motor cooling. Always provide the casing internal diameter, not just the nominal well size, when requesting a quotation.

Total Dynamic Head (TDH): The Core Calculation

The single most important parameter for deep well pump selection is Total Dynamic Head — the total resistance the pump must overcome. It is not the well depth.

TDH = Hdynamic + Helevation + Hpressure + Hfriction

Component Breakdown

ComponentSymbolDescriptionHow to Determine
Dynamic water levelHdynamicWater level during pumpingPump test or specific yield curve
Elevation liftHelevationHeight from ground to discharge pointSite survey
Pressure headHpressureRequired outlet pressureApplication requirement
Friction lossesHfrictionPipe, valves, fittings resistanceDarcy-Weisbach or Hazen-Williams

Pressure-to-Head Conversion

Hm = (Pbar × 100,000) / (ρ × g) = Pbar × 10.2

Required PressureEquivalent Head
1 bar10.2 m
2 bar20.4 m
3 bar30.6 m
4 bar40.8 m
5 bar51.0 m

Complete Sizing Example: Industrial Borehole

Project: Water supply from borehole to elevated storage tank for a small community

Input Data

ParameterValue
Required flow rate40 m³/h
Static water level30 m below ground
Drawdown at 40 m³/h10 m (from specific yield test)
Dynamic water level30 + 10 = 40 m
Tank elevation above ground15 m
Horizontal pipe distance100 m
Pipe materialSteel, DN80
Discharge pressure0 bar (gravity feed to tank)
Valves & fittings1 check valve, 3 × 90° elbows

Step-by-Step Calculation

Step 1: Determine Flow Velocity

v = Q / A = (40/3600) / (π × 0.08² / 4) ≈ 2.21 m/s

Design Check: Velocity of 2.21 m/s is within the recommended 1.5–3.0 m/s range for steel discharge pipes.

Step 2: Calculate Friction Losses

hf = 8.2 m/100m × (140m / 100) = 11.5 m 
Local losses: Check valve (0.09 m) + 3 elbows (0.21 m) = 0.30 m 
Hfriction = 11.5 + 0.30 = 11.8 m

Step 3 & 4: Calculate Static Head & Total Dynamic Head

Hstatic = Hdynamic + Helevation = 40 + 15 = 55 m 
TDH = Hstatic + Hfriction = 55 + 11.8 = 66.8 m

Step 5: Select Pump from Catalog

From manufacturer curves, select a pump where the duty point (40 m³/h @ 66.8 m) falls within the preferred operating range of 70–120% of nominal capacity and near the Best Efficiency Point (BEP). 
Selected: CRS 8-40/6-15 pump — 40 m³/h @ 90 m head (provides margin for future demand increase and wear).

Pump Selection Example: Domestic Deep Well

Project: 2-story house with garden, water at 70 m depth

ParameterValue
Bathrooms / Storeys2 / 2
Static / Dynamic water level70 m / 75 m (5m drawdown)
Highest fixture elevation6 m above ground
System pressure loss20% of geometric head
Required residual pressure2 bar (20.4 m)

Hgeo = 70 + (3 × 2) = 76 m 
Hsystem = 20% × 76 = 15.2 m 
TDH = 76 + 15.2 + 20.4 = 111.6 m ≈ 112 m

From flow rate tables for 2 bathrooms: Q = 1.7 m³/h. Selected: 4-inch submersible pump, 1.7 m³/h @ 112 m head (e.g., S4C-25 model).

Friction Loss Reference Tables

Steel Pipe Head Loss (m per 100 m)

Flow (m³/h)DN50DN65DN80DN100DN125
106.52.10.70.20.1
2023.87.62.50.80.3
3051.216.35.41.70.6
40—28.29.32.91.1
50—43.414.34.51.7

Plastic Pipe (PE/HDPE) Head Loss (m per 100 m)

Flow (m³/h)d40d50d63d75d90
58.93.21.00.40.2
1032.611.73.71.50.7
1570.025.17.93.21.5
20—43.413.75.52.6
25——21.08.44.0

Design Guideline: Plastic pipes have significantly lower friction than steel. When replacing steel with plastic, you may reduce pipe diameter by one nominal size while maintaining equivalent or better hydraulic performance.

Cable Selection & Voltage Drop

Submersible motors require specialized cables rated for underwater installation. The cable must be sized to limit voltage drop to maximum 2% of nominal voltage.

ΔV = (√3 × I × L × cosϕ × Rcable) / 1000

Motor PowerNominal CurrentCable LengthMin. Cross-Section
1.5 kW6.5 A100 m2.5 mm²
3.0 kW12 A100 m4 mm²
5.5 kW20 A150 m6 mm²
7.5 kW27 A150 m10 mm²
11 kW38 A200 m16 mm²
15 kW50 A200 m25 mm²
22 kW72 A250 m35 mm²

Example: HMS Ciris 8-25-125 pump, 13 kW, 33 A nominal current, 160 m cable length → 25 mm² cross-section required.

Motor Cooling & Installation Depth

Critical Cooling Requirement

The submersible motor relies on water flow past its housing for cooling. Insufficient flow causes overheating and premature failure. Minimum flow velocity past motor: vmin = 0.2 m/s.

Casing IDMax Pump OD @ 40 m³/hMax Pump OD @ 80 m³/h
150 mm (6")143 mm138 mm
200 mm (8")193 mm189 mm
250 mm (10")243 mm240 mm

Warning: Installing a pump in an oversized casing without a cooling shroud reduces water velocity past the motor, leading to overheating and shortened operational life.

Installation Depth Guidelines

ParameterRequirement
Pump intake strainerMinimum 1 m below dynamic water level
Motor bottomMinimum 1 m above well screen/filter
Total pump lengthMust fit within straight section of casing
Cable routingAlongside riser pipe, secured with cable guards

Control, Protection & Materials

Essential Protection Functions

ProtectionPurposeImplementation
Overload protectionPrevent motor burnout from excessive currentThermal relays or electronic overload
Dry-run protectionPrevent operation without waterFloat switch, level sensor, or current monitoring
Under/overvoltageProtect motor from power quality issuesVoltage monitoring relay
Soft startEliminate water hammer, reduce starting currentSoft starter or VFD (recommended ≥7.5 kW)

Material Selection for Water Chemistry

Water ConditionRecommended MaterialAvoid
Clean water, pH 6.5–8.5Stainless steel 304Cast iron (rust)
Aggressive water, high chloridesStainless steel 316304 SS (pitting)
High TDS (>2000 ppm)Duplex stainless steelStandard 304/316
High sand content (>50 g/m³)Sand-resistant with floating impellersFixed impeller designs
Seawater / brackishDuplex 2205 or titaniumAll standard grades

Common Selection & Installation Mistakes

MistakeConsequencePrevention
Sizing by well depth aloneUndersized or oversized pump; energy wasteAlways calculate TDH with dynamic water level
Exceeding well yieldDry running, motor burnout, well damagePump flow ≤ tested well yield
Undersized discharge pipeExcessive friction, reduced flow, high energy costMatch pipe to pump outlet; velocity 1.5–3 m/s
Oversized casing without cooling shroudMotor overheating, shortened lifeInstall cooling sleeve or select larger pump diameter
Undersized cableVoltage drop, motor overheating, starting failureSize cable for 2% max voltage drop
Installing pump below screen/filterSand ingress, rapid wear, motor damageMaintain 1 m minimum clearance above screen

Energy Optimization: Variable Speed Drives

Modern deep well pump systems increasingly incorporate Variable Frequency Drives (VFD) for energy savings and operational flexibility.

Operating ConditionFixed SpeedVFD-ControlledSavings
Peak demand (100% flow)100% power100% power0%
Average demand (75% flow)100% power (throttled)42% power58%
Low demand (50% flow)100% power (bypassed)12.5% power87.5%

VFD Benefits: Beyond energy savings, VFDs enable soft starting (eliminating water hammer), precise pressure control, automatic pump curve optimization, and integration with SCADA/remote monitoring systems.

Maintenance Schedule

TaskFrequencyPurpose
Check control panel indicatorsMonthlyEarly fault detection
Measure operating currentQuarterlyDetect motor degradation
Inspect cable entry sealAnnuallyPrevent water ingress
Pull pump for inspectionEvery 3–5 yearsAssess impeller wear, sand damage
Well yield testEvery 5 yearsVerify aquifer performance

Conclusion

Deep well pumps are the engineering solution to one of humanity's oldest challenges: accessing groundwater reliably and efficiently. The technology has evolved from simple piston pumps to sophisticated multistage centrifugal systems capable of delivering hundreds of cubic meters per hour from depths exceeding 500 meters.

The key to successful deep well pump installation lies not in selecting the most powerful pump, but in rigorous calculation of Total Dynamic Head, matching pump performance to well characteristics, proper material selection for water chemistry, and ensuring adequate motor cooling and electrical protection. For every meter of unnecessary head or every millimeter of undersized cable, the system pays a price in energy, reliability, and lifespan. The investment in accurate engineering at the selection stage pays dividends for decades of trouble-free operation.

Get Expert Deep Well Pump Consultation

Choose the right submersible pump system for your borehole project. Our technical team specializes in well pump sizing, TDH calculation, and material selection. Response within 24 hours!

📞 +86 13305761511

✉️ info@cntecho.com

💬 WhatsApp: Nancy / Jahor

Get Free Custom Quote Now → 

LATEST

INFORMATION

Get the latest product information of the company

%{tishi_zhanwei}%

CONTACT US

Telephone: +86 13305761511
Email: info@cntecho.com

Add: RM. 602, BUILDING B, NO.1551 SHUANGSHUI RD., LUQIAO DIST., TAIZHOU CITY, ZHEJIANG, CHINA

 


Copyright © 2026 TECHO ELECTRICAL & MECHANICAL (TAIZHOU) CO., LTD. All Rights Reserved.

Business License

Search for the product name you want to search

TECHO ELECTRICAL & MECHANICAL

%{tishi_zhanwei}%