Jun 23,2026
CHL/CHLF Horizontal Multistage Pumps for HVAC & Water Systems
CHL/CHLF horizontal multistage pumps provide compact, high‑efficiency pressure boosting for HVAC, water treatment, industrial washing, and process systems with stainless steel wetted parts.
Introduction: The Horizontal Alternative in Multistage Pump Technology
The CHL/CHLF(T) series horizontal multistage centrifugal pump represents a space-optimized solution for applications where vertical pump installation is impractical or where low center-of-gravity mounting is preferred for vibration and stability considerations. Unlike its vertical counterpart (CDL/CDLF), the CHL/CHLF(T) series features a horizontal inline configuration with the pump section mounted directly on a common baseplate with a long-shaft TEFC motor, enabling side-by-side installation in mechanical rooms, skid-mounted systems, and confined equipment bays.
Engineered in accordance with ISO 2858, ISO 5199, and GB/T 5657 standards, the CHL/CHLF(T) series employs stamped stainless steel flow passage components combined with cast iron or stainless steel inlet/outlet sections. With flow capacities from 0.5 m³/h to 32 m³/h, heads up to 88 meters, and power ratings from 0.37 kW to 7.5 kW, the CHL/CHLF(T) series addresses the complete spectrum of air-conditioning circulation, industrial washing, water purification, and light chemical transfer applications.
1. Multistage Pump Fundamentals: Hydraulic Principles
1.1 Stage Head & Total Head Relationship
In a multistage centrifugal pump, the total head is the cumulative sum of the head developed by each individual stage:
Htotal = n × Hstage
Example Calculation:
For a CHLF4-50 pump with 5 stages, each developing approximately 7.6 m at rated flow:
Htotal = 5 × 7.6 m/stage = 38 m
1.2 Hydraulic Power & Efficiency
Pshaft = (ρ × g × Q × H) / (1000 × ηoverall)
The CHL/CHLF(T) series achieves pump hydraulic efficiencies of 41–64% depending on flow series and operating point proximity to the Best Efficiency Point (BEP).
1.3 Specific Speed & Impeller Geometry
Ns = n × √Q / Hstage0.75
For the CHLF4-40 pump (n=2900 RPM, Q=4 m³/h, Hstage ≈ 7.5 m): Ns ≈ 2290, indicating a mixed-flow impeller design optimized for the low-flow, moderate-head-per-stage application space.
1.4 NPSH & Cavitation Analysis
NPSHa = (Pinlet − Pvapor) / (ρg) ≥ NPSHr + 0.5 m
For hot water circulation applications (up to +110°C), Pvapor increases significantly, requiring pressurized inlet conditions or subcooling to prevent cavitation.
2. CHL/CHLF(T) Series Technical Specifications
2.1 General Operating Parameters
| Parameter | Specification |
|---|---|
| Pump Type | Horizontal multistage non-self-priming centrifugal pump |
| Construction | CHL: Full SS; CHLF/CHLT: Cast iron inlet/outlet + SS wetted internals |
| Standard Compliance | ISO 2858, ISO 5199, GB/T 5657 |
| Power Range | 0.37 kW – 7.5 kW |
| Flow Range | 0.5 m³/h – 32 m³/h (50 Hz); 1 m³/h – 32 m³/h (60 Hz) |
| Head Range | 6 m – 60 m (50 Hz); 8.5 m – 88 m (60 Hz) |
| Voltage / Frequency | 1×220-240V / 3×220-240V/380-415V / 50 Hz (standard) |
| Rotational Speed | 2900 RPM (50 Hz); 3500 RPM (60 Hz) |
| Stage Count | 1 – 6 stages |
| Medium Temperature | -15°C to +70°C (normal); -15°C to +110°C (hot water) |
| Max Working Pressure | 10 bar (1.0 MPa) |
| Inlet/Outlet Connection | Threaded (G/NPT): G1 (25 mm) to G2 (50 mm) |
2.2 Model Nomenclature
Example: CHLF4-50
CHLF: Light horizontal multistage centrifugal pump with cast iron inlet/outlet and stainless steel wetted parts
4: Design flow rate = 4 m³/h
50: Stage count indicator (5 stages × 10); actual stages = 5
Variant Codes:
- CHL: Full stainless steel construction (all parts including inlet/outlet in AISI 304)
- CHLF: Cast iron inlet/outlet with AISI 304 stainless steel impellers, diffusers, shaft
- CHLT: Cast iron inlet/outlet with stainless steel wetted parts (economy variant)
3. Performance Data Tables
3.1 CHL/CHLF(T)2 Series: 2 m³/h Design Flow
| Model | Flow Q (m³/h) | Head H (m) | Power P (kW) | Efficiency η (%) | Stages | Weight (kg) |
|---|---|---|---|---|---|---|
| CHL/CHLF(T)2-20 | 2 | 15 | 0.37 | 41 | 2 | 13 |
| CHL/CHLF(T)2-30 | 2 | 22 | 0.37 | 41 | 3 | 13 |
| CHL/CHLF(T)2-40 | 2 | 29 | 0.55 | 41 | 4 | 13 |
| CHL/CHLF(T)2-50 | 2 | 36 | 0.55 | 41 | 5 | 13 |
| CHL/CHLF(T)2-60 | 2 | 44 | 0.75 | 41 | 6 | 15 |
3.2 CHL/CHLF(T)4 Series: 4 m³/h Design Flow
| Model | Flow Q (m³/h) | Head H (m) | Power P (kW) | Efficiency η (%) | Stages | Weight (kg) |
|---|---|---|---|---|---|---|
| CHL/CHLF(T)4-20 | 4 | 15 | 0.37 | 49 | 2 | 12 |
| CHL/CHLF(T)4-30 | 4 | 23.5 | 0.55 | 49 | 3 | 12 |
| CHL/CHLF(T)4-40 | 4 | 31 | 0.75 | 49 | 4 | 15 |
| CHL/CHLF(T)4-50 | 4 | 38 | 1.1 | 49 | 5 | 16 |
| CHL/CHLF(T)4-60 | 4 | 45 | 1.1 | 49 | 6 | 17 |
3.3 CHL/CHLF(T)8 Series: 8 m³/h Design Flow
| Model | Flow Q (m³/h) | Head H (m) | Power P (kW) | Efficiency η (%) | Stages | Weight (kg) |
|---|---|---|---|---|---|---|
| CHL/CHLF(T)8-10 | 8 | 8.5 | 0.75 | 57 | 1 | 20 |
| CHL/CHLF(T)8-20 | 8 | 17 | 0.75 | 57 | 2 | 20 |
| CHL/CHLF(T)8-30 | 8 | 25.5 | 1.1 | 57 | 3 | 25 |
| CHL/CHLF(T)8-40 | 8 | 34 | 1.5 | 57 | 4 | 25 |
| CHL/CHLF(T)8-50 | 8 | 42.5 | 2.2 | 57 | 5 | 30 |
3.4 CHL/CHLF(T)12 Series: 12 m³/h Design Flow
| Model | Flow Q (m³/h) | Head H (m) | Power P (kW) | Efficiency η (%) | Stages | Weight (kg) |
|---|---|---|---|---|---|---|
| CHL/CHLF(T)12-10 | 12 | 9.5 | 0.75 | 60 | 1 | 20 |
| CHL/CHLF(T)12-20 | 12 | 19.5 | 1.2 | 60 | 2 | 21 |
| CHL/CHLF(T)12-30 | 12 | 29.5 | 1.8 | 60 | 3 | 25 |
| CHL/CHLF(T)12-40 | 12 | 39.5 | 2.4 | 60 | 4 | 29 |
| CHL/CHLF(T)12-50 | 12 | 50 | 3.0 | 60 | 5 | 34 |
3.5 CHL/CHLF(T)16 Series: 16 m³/h Design Flow
| Model | Flow Q (m³/h) | Head H (m) | Power P (kW) | Efficiency η (%) | Stages | Weight (kg) |
|---|---|---|---|---|---|---|
| CHL/CHLF(T)16-10 | 16 | 10.5 | 1.1 | 62 | 1 | 20 |
| CHL/CHLF(T)16-20 | 16 | 21.7 | 2.2 | 62 | 2 | 27 |
| CHL/CHLF(T)16-30 | 16 | 34 | 3.0 | 62 | 3 | 34 |
| CHL/CHLF(T)16-40 | 16 | 43 | 4.0 | 62 | 4 | — |
3.6 CHL/CHLF(T)20 Series: 20 m³/h Design Flow
| Model | Flow Q (m³/h) | Head H (m) | Power P (kW) | Efficiency η (%) | Stages | Weight (kg) |
|---|---|---|---|---|---|---|
| CHL/CHLF(T)20-10 | 20 | 10 | 1.1 | 64 | 1 | 21 |
| CHL/CHLF(T)20-20 | 20 | 22 | 2.2 | 64 | 2 | 28 |
| CHL/CHLF(T)20-30 | 20 | 34 | 4.0 | 64 | 3 | 42 |
| CHL/CHLF(T)20-40 | 20 | 44.5 | 4.4 | 64 | 4 | — |
Note: All performance data represents nominal values at rated voltage, frequency, and clean water conditions. CHLF(T) series performance is identical to CHL series for equivalent flow and stage count.
4. Structural Design & Material Engineering
4.1 Stamped Stainless Steel Flow Passage Components
| Component | Manufacturing Method | Material | Advantage |
|---|---|---|---|
| Impeller | Deep drawing + stamping | AISI 304 SS | Precise vane geometry; smooth surface (Ra ≤ 1.6 μm) |
| Diffuser | Stamping + welding | AISI 304 SS | Accurate flow channel dimensions; minimal hydraulic losses |
| Shaft | CNC machining | AISI 304 SS | Dimensional accuracy; corrosion resistance |
| Inlet/Outlet (CHL) | Stamping + welding | AISI 304 SS | Full corrosion resistance; hygienic surface finish |
| Inlet/Outlet (CHLF) | Sand casting | Cast iron (EN-GJL-200) | Cost-effective; adequate strength for threaded connections |
4.2 Horizontal Inline Configuration
- Axial inlet, radial outlet: Minimizes inlet losses and enables compact piping layouts
- Common baseplate mounting: Ensures alignment stability and simplifies installation
- Side-by-side installation: Allows multiple pumps to be installed in parallel banks within limited headroom spaces
- Easy maintenance: Motor removal and seal replacement accessible from either end without disturbing piping
4.3 Mechanical Seal & Bearing System
| Component | Specification | Function |
|---|---|---|
| Mechanical Seal | SiC vs. Carbon (standard); SiC vs. SiC (optional) | High-pressure sealing; wear-resistant |
| Drive-End Bearing | Deep-groove ball bearing | Supports rotor weight and radial hydraulic forces |
| Non-Drive-End Bearing | Deep-groove ball bearing | Absorbs residual axial thrust |
5. Motor Engineering & Drive Options
5.1 Standard Motor Configuration
| Parameter | Specification |
|---|---|
| Motor Type | TEFC squirrel-cage induction motor |
| Speed | 2900 RPM (50 Hz); 3500 RPM (60 Hz) |
| Efficiency Class | IE2 (standard); IE3 (premium efficiency option) |
| Insulation / Protection | Class F (155°C) / IP55 |
| Mounting | B3 (foot mounted) with B5 flange adapter |
5.2 Variable Frequency Drive (VFD) Compatibility
The CHL/CHLF(T) series is compatible with VFD operation for energy-efficient flow control:
Q2 = Q1 × (f2 / f1) | H2 = H1 × (f2 / f1)2 | P2 = P1 × (f2 / f1)3
VFD Minimum Frequency: Do not operate below 25 Hz (50% of rated speed) to maintain adequate bearing grease migration and cooling fan effectiveness.
6. Application Engineering & Selection Guidelines
6.1 Duty Point Selection & System Head
The optimal pump selection positions the system operating point within the thickened curve region:
Qmin ≈ 0.5 × Qrated to Qmax ≈ 1.1 × Qrated
For pressure boosting and circulation applications:
Hpump = Hstatic + Hfriction + Hpressure + Hvelocity − Hsuction
6.2 Typical Application Scenarios
| Application | Recommended Model Range | Key Selection Criteria |
|---|---|---|
| Air-conditioning chilled water | CHLF8-20 to CHLF20-30 | Moderate head; VFD-compatible for part-load efficiency |
| Industrial washing & cleaning | CHLF4-30 to CHLF8-40 | Moderate pressure for spray nozzles; SS for detergent compatibility |
| Water treatment (RO/UF) | CHLF2-40 to CHLF4-50 | High pressure for membrane feed; sanitary construction |
| Boiler hot water circulation | CHLF8-20 to CHLF12-30 | High temperature capability (+110°C); reliable bearing system |
| Food & beverage CIP systems | CHL full 316 SS | FDA compliance; hygienic surface; chemical cleaning compatibility |
| Pressure boosting stations | CHLF4-40 to CHLF12-40 | Stacked head for building height; parallel configuration |
7. Installation, Operation & Maintenance
7.1 Installation Requirements
| Parameter | Requirement |
|---|---|
| Foundation | Rigid, level concrete pad or steel frame; anchor bolts for vibration isolation |
| Pump Alignment | Shaft alignment within 0.05 mm parallel and 0.05 mm/m angular tolerance |
| Piping Support | Independent pipe supports; no pipe strain transmitted to pump flanges |
| Suction Conditions | Flooded suction preferred; verify NPSHa > NPSHr + 0.5 m |
7.2 Maintenance Protocol
| Inspection Item | Frequency | Action |
|---|---|---|
| Mechanical seal leakage | Monthly | Replace if drip rate exceeds 5 drops/minute |
| Bearing temperature | Monthly | Investigate if >80°C or ΔT >15°C from ambient |
| Vibration analysis | Quarterly | ISO 10816 criteria; velocity >4.5 mm/s RMS requires investigation |
| Motor current draw | Monthly | Compare to baseline; investigate deviations >10% |
| Impeller wear | Annually | Inspect for erosion, corrosion, or cavitation pitting |
8. Ordering Information & Custom Engineering
8.1 Required Specification Data
| Parameter | Example Value |
|---|---|
| Pump Model | CHLF8-40 |
| Fluid Type | Chilled water / Soft water / Light chemical |
| Flow Rate (Q) | 8 m³/h |
| Total Dynamic Head (H) | 34 m |
| Material Specification | CHLF (cast iron inlet/outlet + AISI 304 internals) |
| Connection Type | Threaded G2 (50 mm) |
8.2 Custom Engineering Options
- AISI 316 full construction: Enhanced chloride resistance for seawater and aggressive chemicals
- High-temperature execution: Up to +110°C with special seal materials
- Double mechanical seal: Barrier fluid system for hazardous fluids
- Special surface finish: Electropolished to Ra ≤ 0.4 μm for pharmaceutical applications
- Explosion-proof motors: ATEX/IECEx certified motors for Zone 1/Zone 2 hazardous areas
9. Why Choose CHL/CHLF(T) Series for Your Fluid Handling Needs?
| Engineering Criterion | CHL/CHLF(T) Series Advantage |
|---|---|
| Horizontal Configuration | Low center of gravity; stable mounting; ideal for mechanical rooms with headroom constraints |
| Corrosion Resistance | AISI 304 stainless steel wetted parts eliminate rust and scaling; AISI 316 option available |
| Hydraulic Efficiency | Stamped impellers achieve 41–64% efficiency; smooth surfaces reduce friction losses |
| Compact Footprint | Inline design minimizes floor space; multiple pumps install side-by-side in banks |
| Energy Savings | VFD-compatible for variable-flow systems; affinity law cubic power reduction |
| Maintenance Accessibility | Horizontal alignment enables easy seal and bearing service without pump removal |
| Temperature Range | Normal type -15°C to +70°C; hot water type up to +110°C |
| Cost Flexibility | CHL (full SS) for maximum corrosion resistance; CHLF/CHLT (hybrid) for cost-optimized applications |
Get a Free Custom Quote for CHL/CHLF(T) Horizontal Multistage Pumps
Choose TITECHO's CHL/CHLF(T) series for space-saving horizontal design, superior hydraulic efficiency, and reliable pressure boosting. Our team responds within 24 hours!
📞 +86 13305761511
✉️ info@cntecho.com
💬 WhatsApp: Nancy / Jahor
Related News
LATEST
INFORMATION
Get the latest product information of the company
NAVIGATION
PRODUCTS
CONTACT US
Telephone: +86 13305761511
Email: info@cntecho.com
Add: RM. 602, BUILDING B, NO.1551 SHUANGSHUI RD., LUQIAO DIST., TAIZHOU CITY, ZHEJIANG, CHINA
Copyright © 2026 TECHO ELECTRICAL & MECHANICAL (TAIZHOU) CO., LTD. All Rights Reserved.