CHL/CHLF Horizontal Multistage Pumps for HVAC & Water Systems

CHL/CHLF horizontal multistage pumps provide compact, high‑efficiency pressure boosting for HVAC, water treatment, industrial washing, and process systems with stainless steel wetted parts.


Introduction: The Horizontal Alternative in Multistage Pump Technology

The CHL/CHLF(T) series horizontal multistage centrifugal pump represents a space-optimized solution for applications where vertical pump installation is impractical or where low center-of-gravity mounting is preferred for vibration and stability considerations. Unlike its vertical counterpart (CDL/CDLF), the CHL/CHLF(T) series features a horizontal inline configuration with the pump section mounted directly on a common baseplate with a long-shaft TEFC motor, enabling side-by-side installation in mechanical rooms, skid-mounted systems, and confined equipment bays.

Engineered in accordance with ISO 2858, ISO 5199, and GB/T 5657 standards, the CHL/CHLF(T) series employs stamped stainless steel flow passage components combined with cast iron or stainless steel inlet/outlet sections. With flow capacities from 0.5 m³/h to 32 m³/h, heads up to 88 meters, and power ratings from 0.37 kW to 7.5 kW, the CHL/CHLF(T) series addresses the complete spectrum of air-conditioning circulation, industrial washing, water purification, and light chemical transfer applications.

1. Multistage Pump Fundamentals: Hydraulic Principles

1.1 Stage Head & Total Head Relationship

In a multistage centrifugal pump, the total head is the cumulative sum of the head developed by each individual stage:

Htotal = n × Hstage

Example Calculation: 
For a CHLF4-50 pump with 5 stages, each developing approximately 7.6 m at rated flow: 
Htotal = 5 × 7.6 m/stage = 38 m

1.2 Hydraulic Power & Efficiency

Pshaft = (ρ × g × Q × H) / (1000 × ηoverall)

The CHL/CHLF(T) series achieves pump hydraulic efficiencies of 41–64% depending on flow series and operating point proximity to the Best Efficiency Point (BEP).

1.3 Specific Speed & Impeller Geometry

Ns = n × √Q / Hstage0.75

For the CHLF4-40 pump (n=2900 RPM, Q=4 m³/h, Hstage ≈ 7.5 m): Ns ≈ 2290, indicating a mixed-flow impeller design optimized for the low-flow, moderate-head-per-stage application space.

1.4 NPSH & Cavitation Analysis

NPSHa = (Pinlet − Pvapor) / (ρg) ≥ NPSHr + 0.5 m

For hot water circulation applications (up to +110°C), Pvapor increases significantly, requiring pressurized inlet conditions or subcooling to prevent cavitation.

2. CHL/CHLF(T) Series Technical Specifications

2.1 General Operating Parameters

ParameterSpecification
Pump TypeHorizontal multistage non-self-priming centrifugal pump
ConstructionCHL: Full SS; CHLF/CHLT: Cast iron inlet/outlet + SS wetted internals
Standard ComplianceISO 2858, ISO 5199, GB/T 5657
Power Range0.37 kW – 7.5 kW
Flow Range0.5 m³/h – 32 m³/h (50 Hz); 1 m³/h – 32 m³/h (60 Hz)
Head Range6 m – 60 m (50 Hz); 8.5 m – 88 m (60 Hz)
Voltage / Frequency1×220-240V / 3×220-240V/380-415V / 50 Hz (standard)
Rotational Speed2900 RPM (50 Hz); 3500 RPM (60 Hz)
Stage Count1 – 6 stages
Medium Temperature-15°C to +70°C (normal); -15°C to +110°C (hot water)
Max Working Pressure10 bar (1.0 MPa)
Inlet/Outlet ConnectionThreaded (G/NPT): G1 (25 mm) to G2 (50 mm)

2.2 Model Nomenclature

Example: CHLF4-50 
CHLF: Light horizontal multistage centrifugal pump with cast iron inlet/outlet and stainless steel wetted parts 
4: Design flow rate = 4 m³/h 
50: Stage count indicator (5 stages × 10); actual stages = 5

Variant Codes:

  • CHL: Full stainless steel construction (all parts including inlet/outlet in AISI 304)
  • CHLF: Cast iron inlet/outlet with AISI 304 stainless steel impellers, diffusers, shaft
  • CHLT: Cast iron inlet/outlet with stainless steel wetted parts (economy variant)

3. Performance Data Tables

3.1 CHL/CHLF(T)2 Series: 2 m³/h Design Flow

ModelFlow Q (m³/h)Head H (m)Power P (kW)Efficiency η (%)StagesWeight (kg)
CHL/CHLF(T)2-202150.3741213
CHL/CHLF(T)2-302220.3741313
CHL/CHLF(T)2-402290.5541413
CHL/CHLF(T)2-502360.5541513
CHL/CHLF(T)2-602440.7541615

3.2 CHL/CHLF(T)4 Series: 4 m³/h Design Flow

ModelFlow Q (m³/h)Head H (m)Power P (kW)Efficiency η (%)StagesWeight (kg)
CHL/CHLF(T)4-204150.3749212
CHL/CHLF(T)4-30423.50.5549312
CHL/CHLF(T)4-404310.7549415
CHL/CHLF(T)4-504381.149516
CHL/CHLF(T)4-604451.149617

3.3 CHL/CHLF(T)8 Series: 8 m³/h Design Flow

ModelFlow Q (m³/h)Head H (m)Power P (kW)Efficiency η (%)StagesWeight (kg)
CHL/CHLF(T)8-1088.50.7557120
CHL/CHLF(T)8-208170.7557220
CHL/CHLF(T)8-30825.51.157325
CHL/CHLF(T)8-408341.557425
CHL/CHLF(T)8-50842.52.257530

3.4 CHL/CHLF(T)12 Series: 12 m³/h Design Flow

ModelFlow Q (m³/h)Head H (m)Power P (kW)Efficiency η (%)StagesWeight (kg)
CHL/CHLF(T)12-10129.50.7560120
CHL/CHLF(T)12-201219.51.260221
CHL/CHLF(T)12-301229.51.860325
CHL/CHLF(T)12-401239.52.460429
CHL/CHLF(T)12-5012503.060534

3.5 CHL/CHLF(T)16 Series: 16 m³/h Design Flow

ModelFlow Q (m³/h)Head H (m)Power P (kW)Efficiency η (%)StagesWeight (kg)
CHL/CHLF(T)16-101610.51.162120
CHL/CHLF(T)16-201621.72.262227
CHL/CHLF(T)16-3016343.062334
CHL/CHLF(T)16-4016434.0624—

3.6 CHL/CHLF(T)20 Series: 20 m³/h Design Flow

ModelFlow Q (m³/h)Head H (m)Power P (kW)Efficiency η (%)StagesWeight (kg)
CHL/CHLF(T)20-1020101.164121
CHL/CHLF(T)20-2020222.264228
CHL/CHLF(T)20-3020344.064342
CHL/CHLF(T)20-402044.54.4644—

Note: All performance data represents nominal values at rated voltage, frequency, and clean water conditions. CHLF(T) series performance is identical to CHL series for equivalent flow and stage count.

4. Structural Design & Material Engineering

4.1 Stamped Stainless Steel Flow Passage Components

ComponentManufacturing MethodMaterialAdvantage
ImpellerDeep drawing + stampingAISI 304 SSPrecise vane geometry; smooth surface (Ra ≤ 1.6 μm)
DiffuserStamping + weldingAISI 304 SSAccurate flow channel dimensions; minimal hydraulic losses
ShaftCNC machiningAISI 304 SSDimensional accuracy; corrosion resistance
Inlet/Outlet (CHL)Stamping + weldingAISI 304 SSFull corrosion resistance; hygienic surface finish
Inlet/Outlet (CHLF)Sand castingCast iron (EN-GJL-200)Cost-effective; adequate strength for threaded connections

4.2 Horizontal Inline Configuration

  • Axial inlet, radial outlet: Minimizes inlet losses and enables compact piping layouts
  • Common baseplate mounting: Ensures alignment stability and simplifies installation
  • Side-by-side installation: Allows multiple pumps to be installed in parallel banks within limited headroom spaces
  • Easy maintenance: Motor removal and seal replacement accessible from either end without disturbing piping

4.3 Mechanical Seal & Bearing System

ComponentSpecificationFunction
Mechanical SealSiC vs. Carbon (standard); SiC vs. SiC (optional)High-pressure sealing; wear-resistant
Drive-End BearingDeep-groove ball bearingSupports rotor weight and radial hydraulic forces
Non-Drive-End BearingDeep-groove ball bearingAbsorbs residual axial thrust

5. Motor Engineering & Drive Options

5.1 Standard Motor Configuration

ParameterSpecification
Motor TypeTEFC squirrel-cage induction motor
Speed2900 RPM (50 Hz); 3500 RPM (60 Hz)
Efficiency ClassIE2 (standard); IE3 (premium efficiency option)
Insulation / ProtectionClass F (155°C) / IP55
MountingB3 (foot mounted) with B5 flange adapter

5.2 Variable Frequency Drive (VFD) Compatibility

The CHL/CHLF(T) series is compatible with VFD operation for energy-efficient flow control:

Q2 = Q1 × (f2 / f1)   |   H2 = H1 × (f2 / f1)2   |   P2 = P1 × (f2 / f1)3

VFD Minimum Frequency: Do not operate below 25 Hz (50% of rated speed) to maintain adequate bearing grease migration and cooling fan effectiveness.

6. Application Engineering & Selection Guidelines

6.1 Duty Point Selection & System Head

The optimal pump selection positions the system operating point within the thickened curve region: 
Qmin ≈ 0.5 × Qrated to Qmax ≈ 1.1 × Qrated

For pressure boosting and circulation applications: 
Hpump = Hstatic + Hfriction + Hpressure + Hvelocity − Hsuction

6.2 Typical Application Scenarios

ApplicationRecommended Model RangeKey Selection Criteria
Air-conditioning chilled waterCHLF8-20 to CHLF20-30Moderate head; VFD-compatible for part-load efficiency
Industrial washing & cleaningCHLF4-30 to CHLF8-40Moderate pressure for spray nozzles; SS for detergent compatibility
Water treatment (RO/UF)CHLF2-40 to CHLF4-50High pressure for membrane feed; sanitary construction
Boiler hot water circulationCHLF8-20 to CHLF12-30High temperature capability (+110°C); reliable bearing system
Food & beverage CIP systemsCHL full 316 SSFDA compliance; hygienic surface; chemical cleaning compatibility
Pressure boosting stationsCHLF4-40 to CHLF12-40Stacked head for building height; parallel configuration

7. Installation, Operation & Maintenance

7.1 Installation Requirements

ParameterRequirement
FoundationRigid, level concrete pad or steel frame; anchor bolts for vibration isolation
Pump AlignmentShaft alignment within 0.05 mm parallel and 0.05 mm/m angular tolerance
Piping SupportIndependent pipe supports; no pipe strain transmitted to pump flanges
Suction ConditionsFlooded suction preferred; verify NPSHa > NPSHr + 0.5 m

7.2 Maintenance Protocol

Inspection ItemFrequencyAction
Mechanical seal leakageMonthlyReplace if drip rate exceeds 5 drops/minute
Bearing temperatureMonthlyInvestigate if >80°C or ΔT >15°C from ambient
Vibration analysisQuarterlyISO 10816 criteria; velocity >4.5 mm/s RMS requires investigation
Motor current drawMonthlyCompare to baseline; investigate deviations >10%
Impeller wearAnnuallyInspect for erosion, corrosion, or cavitation pitting

8. Ordering Information & Custom Engineering

8.1 Required Specification Data

ParameterExample Value
Pump ModelCHLF8-40
Fluid TypeChilled water / Soft water / Light chemical
Flow Rate (Q)8 m³/h
Total Dynamic Head (H)34 m
Material SpecificationCHLF (cast iron inlet/outlet + AISI 304 internals)
Connection TypeThreaded G2 (50 mm)

8.2 Custom Engineering Options

  • AISI 316 full construction: Enhanced chloride resistance for seawater and aggressive chemicals
  • High-temperature execution: Up to +110°C with special seal materials
  • Double mechanical seal: Barrier fluid system for hazardous fluids
  • Special surface finish: Electropolished to Ra ≤ 0.4 μm for pharmaceutical applications
  • Explosion-proof motors: ATEX/IECEx certified motors for Zone 1/Zone 2 hazardous areas

9. Why Choose CHL/CHLF(T) Series for Your Fluid Handling Needs?

Engineering CriterionCHL/CHLF(T) Series Advantage
Horizontal ConfigurationLow center of gravity; stable mounting; ideal for mechanical rooms with headroom constraints
Corrosion ResistanceAISI 304 stainless steel wetted parts eliminate rust and scaling; AISI 316 option available
Hydraulic EfficiencyStamped impellers achieve 41–64% efficiency; smooth surfaces reduce friction losses
Compact FootprintInline design minimizes floor space; multiple pumps install side-by-side in banks
Energy SavingsVFD-compatible for variable-flow systems; affinity law cubic power reduction
Maintenance AccessibilityHorizontal alignment enables easy seal and bearing service without pump removal
Temperature RangeNormal type -15°C to +70°C; hot water type up to +110°C
Cost FlexibilityCHL (full SS) for maximum corrosion resistance; CHLF/CHLT (hybrid) for cost-optimized applications

Get a Free Custom Quote for CHL/CHLF(T) Horizontal Multistage Pumps

Choose TITECHO's CHL/CHLF(T) series for space-saving horizontal design, superior hydraulic efficiency, and reliable pressure boosting. Our team responds within 24 hours!

📞 +86 13305761511

✉️ info@cntecho.com

💬 WhatsApp: Nancy / Jahor

Get Free Custom Quote Now → 

LATEST

INFORMATION

Get the latest product information of the company

%{tishi_zhanwei}%

CONTACT US

Telephone: +86 13305761511
Email: info@cntecho.com

Add: RM. 602, BUILDING B, NO.1551 SHUANGSHUI RD., LUQIAO DIST., TAIZHOU CITY, ZHEJIANG, CHINA

 


Copyright © 2026 TECHO ELECTRICAL & MECHANICAL (TAIZHOU) CO., LTD. All Rights Reserved.

Business License

Search for the product name you want to search

TECHO ELECTRICAL & MECHANICAL

%{tishi_zhanwei}%