TECHO ELECTRICAL & MECHANICAL

BLOG

Jun 23,2026

CDL/CDLF Vertical Multistage Pumps for Pressure Boosting & RO

cdl cdlf vertical multistage pump, stainless steel multistage pump, high pressure booster pump, ro feed pump


Introduction: The Evolution of Multistage Pump Technology

The CDL/CDLF series vertical multistage centrifugal pump represents a generational advancement in high-pressure fluid handling technology. Unlike conventional cast iron multistage pumps manufactured through sand casting processes, the CDL/CDLF series employs stainless steel sheet stamping, deep drawing, and precision welding to create impellers, diffusers, and pump casings with exceptional dimensional accuracy, surface finish, and material consistency.

This manufacturing methodology delivers:

  • 30–40% weight reduction compared to cast iron equivalents
  • Superior hydraulic efficiency due to precise vane geometry and smooth flow passages
  • Enhanced corrosion resistance from full stainless steel construction
  • Reduced noise and vibration through improved rotor dynamic balance

With flow capacities from 1 m³/h to 120 m³/h, heads up to 250 meters, and power ratings from 0.37 kW to 75 kW, the CDL/CDLF series addresses the complete spectrum of clean water pressure boosting, boiler feed, reverse osmosis, and industrial process applications.

1. Multistage Pump Fundamentals: Hydraulic Principles

1.1 Stage Head & Total Head Relationship

In a multistage centrifugal pump, the total head is the cumulative sum of the head developed by each individual stage:

Htotal = n × Hstage

Where: 
Htotal = Total pump head (m) 
n = Number of stages (impeller/diffuser pairs) 
Hstage = Head per stage (m)

Example: A 25CDLF2-20 pump with 20 stages develops approximately: 
Htotal = 20 × 7.5 m/stage = 150 m 
This modular stage-stacking approach enables the CDL/CDLF series to achieve heads ranging from 15 m to 250 m within a compact vertical envelope, with pump height increasing linearly with stage count.

1.2 Hydraulic Power & Efficiency

Pshaft = (ρ × g × Q × H) / (1000 × ηoverall)

Where: 
ρ = Fluid density (kg/m³); 1000 kg/m³ for water 
g = 9.81 m/s² 
Q = Flow rate (m³/s) 
H = Total dynamic head (m) 
ηoverall = Overall efficiency (pump + motor)

The CDL/CDLF series achieves overall efficiencies of 72–87% depending on flow rate, stage count, and operating point proximity to the Best Efficiency Point (BEP).

1.3 Specific Speed & Impeller Geometry

Ns = n × √Q / Hstage0.75

For the CDL/CDLF series (n=2900 RPM, Q=2 m³/h, Hstage ≈ 7.5 m): 
Ns = (2900 × √0.000556) / 7.50.75 = (2900 × 0.0236) / 4.22 ≈ 16.2 
Converted to conventional metric specific speed: Ns ≈ 1620, indicating a mixed-flow to radial-flow impeller design optimized for moderate flow and moderate-to-high head per stage.

1.4 NPSH & Cavitation Analysis

Net Positive Suction Head required (NPSHr) for the CDL/CDLF series ranges from 1.8 m to 4.5 m depending on flow rate and pump size. The available NPSH must satisfy:

NPSHa = (Pinlet − Pvapor) / (ρg) ≥ NPSHr + 0.5 m

Where: 
Pinlet = Absolute pressure at pump inlet (Pa) 
Pvapor = Fluid vapor pressure at operating temperature (Pa) 
For boiler feed and high-temperature applications, Pvapor increases significantly, requiring elevated inlet pressure or subcooling to prevent cavitation.

2. CDL/CDLF Series Technical Specifications

2.1 General Operating Parameters

ParameterSpecification
Pump TypeVertical multistage centrifugal pump
ConstructionCDL: Cast iron inlet/outlet + stainless steel wetted parts; CDLF: Full AISI 304/316 stainless steel
Standard ComplianceISO 2858, ISO 5199, GB/T 5657
Power Range0.37 kW – 75 kW
Flow Range1 m³/h – 120 m³/h
Head Range4 m – 250 m
Voltage / FrequencyThree-phase 380 V / 50 Hz (standard); 220 V, 415 V, 460 V, 60 Hz (optional)
Rotational Speed2900 RPM (2-pole, 50 Hz)
Stage Count1 – 22 stages (depending on flow series and head requirement)
Medium Temperature-15°C to +120°C (standard); up to +180°C with special seals
Max Working Pressure≤ 2.5 MPa (25 bar) at inlet; ≤ 3.0 MPa at outlet for high-pressure variants
Max Ambient Temperature+40°C
Protection ClassIP55 (standard motor)
Insulation ClassF (standard)
Inlet/Outlet ConnectionThreaded (G/NPT) or Flanged (DN25 – DN125)

2.2 Model Nomenclature

The CDL/CDLF series model designation follows a systematic coding convention: 
[Inlet DN]CDL/CDLF [Flow]-[Stage Count]

Example: 25CDLF2-20 
25: Inlet/outlet nominal diameter = 25 mm 
CDLF: Light vertical multistage centrifugal pump, full stainless steel 
2: Design flow rate = 2 m³/h 
20: Number of stages = 20

Variant Codes:

  • CDL: Standard version with cast iron inlet/outlet sections, stainless steel wetted internal parts
  • CDLF: Full stainless steel version (AISI 304 or AISI 316); all fluid-contact parts in stainless steel
  • Suffix -2, -1: Intermediate stage configurations for fine head adjustment (e.g., CDL32-20-2 vs. CDL32-20)

3. Performance Data Tables

3.1 25CDL/CDLF2 Series: 2 m³/h Design Flow

ModelFlow Q (m³/h)Head H (m)Power P (kW)Efficiency η (%)NPSHr (m)Height (mm)Weight (kg)Stages
25CDL/CDLF2-22150.37721.8445202
25CDL/CDLF2-32220.37721.8463203
25CDL/CDLF2-42300.55721.8481204
25CDL/CDLF2-52370.55721.8499205
25CDL/CDLF2-62450.75741.8522206
25CDL/CDLF2-72520.75741.8540257
25CDL/CDLF2-82601.1741.8548258
25CDL/CDLF2-9267—761.8596259
25CDL/CDLF2-10275—761.86143010
25CDL/CDLF2-11282—761.86323011
25CDL/CDLF2-12290—761.86503012
25CDL/CDLF2-13297—821.86853513
25CDL/CDLF2-142105—821.87033514
25CDL/CDLF2-152112—821.87213515
25CDL/CDLF2-162120—821.87593516
25CDL/CDLF2-172127—821.87774017
25CDL/CDLF2-182135—841.87954018
25CDL/CDLF2-192142—841.88134019
25CDL/CDLF2-202150—841.88314020
25CDL/CDLF2-212157—841.88494021
25CDL/CDLF2-222165—841.88674522
25CDL/CDLF2-232172—841.89184523
25CDL/CDLF2-242180—841.89364524
25CDL/CDLF2-252187—841.89455025
25CDL/CDLF2-262195—861.89725026

3.2 32CDL/CDLF4 Series: 4 m³/h Design Flow

ModelFlow Q (m³/h)Head H (m)Power P (kW)Efficiency η (%)NPSHr (m)Height (mm)Weight (kg)Stages
32CDL/CDLF4-24160.37721.8460202
32CDL/CDLF4-34240.55721.8490203
32CDL/CDLF4-44320.75741.8520204
32CDL/CDLF4-54401.1761.8570205
32CDL/CDLF4-64481.1761.8595206
32CDL/CDLF4-74561.5761.8640257
32CDL/CDLF4-84641.5821.8665258
32CDL/CDLF4-94722.2821.8715309
32CDL/CDLF4-104802.2841.87403010
32CDL/CDLF4-114882.2841.87653011
32CDL/CDLF4-124962.2841.87953012
32CDL/CDLF4-1341043.0841.88603513
32CDL/CDLF4-1441123.0841.88853514
32CDL/CDLF4-1541203.0841.89103515
32CDL/CDLF4-1641283.0861.89353516
32CDL/CDLF4-1741364.0861.810004017
32CDL/CDLF4-1841444.0861.810254018
32CDL/CDLF4-1941524.0871.810504019
32CDL/CDLF4-2041604.0871.810754020
32CDL/CDLF4-2141684.0871.811004521
32CDL/CDLF4-2241764.0871.811304522

3.3 40CDL/CDLF8 Series: 8 m³/h Design Flow

ModelFlow Q (m³/h)Head H (m)Power P (kW)Efficiency η (%)NPSHr (m)Stages
40CDL/CDLF8-28180.75742.32
40CDL/CDLF8-38271.1762.33
40CDL/CDLF8-48361.5762.34
40CDL/CDLF8-58452.2762.35
40CDL/CDLF8-68542.2762.36
40CDL/CDLF8-78633.0762.37
40CDL/CDLF8-88723.0822.38
40CDL/CDLF8-98814.0822.39
40CDL/CDLF8-108904.0842.310
40CDL/CDLF8-118994.0842.311
40CDL/CDLF8-1281084.0842.312
40CDL/CDLF8-1381175.5842.313
40CDL/CDLF8-1481265.5842.314
40CDL/CDLF8-1581355.5842.315
40CDL/CDLF8-1681445.5842.316
40CDL/CDLF8-1781537.5842.317
40CDL/CDLF8-1881627.5842.318
40CDL/CDLF8-1981717.5842.319
40CDL/CDLF8-2081807.5842.320

3.4 50CDL/CDLF12 Series: 12 m³/h Design Flow

ModelFlow Q (m³/h)Head H (m)Power P (kW)Efficiency η (%)Stages
50CDL/CDLF12-212201.5—2
50CDL/CDLF12-312302.2—3
50CDL/CDLF12-412403.0—4
50CDL/CDLF12-512503.0—5
50CDL/CDLF12-612604.0—6
50CDL/CDLF12-712705.5—7
50CDL/CDLF12-812805.5—8
50CDL/CDLF12-912905.5—9
50CDL/CDLF12-10121007.5—10
50CDL/CDLF12-11121107.5—11
50CDL/CDLF12-12121207.5—12
50CDL/CDLF12-13121307.5—13
50CDL/CDLF12-141214011—14
50CDL/CDLF12-151215011—15
50CDL/CDLF12-161216011—16
50CDL/CDLF12-171217011—17
50CDL/CDLF12-181218011—18

3.5 50CDL/CDLF16 Series: 16 m³/h Design Flow (Selection)

ModelFlow Q (m³/h)Head H (m)Power P (kW)Stages
50CDL/CDLF16-216242.22
50CDL/CDLF16-316363.03
50CDL/CDLF16-416484.04
50CDL/CDLF16-516605.55
50CDL/CDLF16-616725.56
50CDL/CDLF16-716847.57
50CDL/CDLF16-816967.58
50CDL/CDLF16-10161181110
50CDL/CDLF16-12161411112
50CDL/CDLF16-14161661514
50CDL/CDLF16-16161891516

3.6 65CDL/CDLF20 Series: 20 m³/h Design Flow (Selection)

ModelFlow Q (m³/h)Head H (m)Power P (kW)Stages
65CDL/CDLF20-220232.22
65CDL/CDLF20-320354.03
65CDL/CDLF20-420475.54
65CDL/CDLF20-520585.55
65CDL/CDLF20-620707.56
65CDL/CDLF20-720827.57
65CDL/CDLF20-82094118
65CDL/CDLF20-10201181110
65CDL/CDLF20-12201421512
65CDL/CDLF20-14201661514
65CDL/CDLF20-172020218.517

3.7 80CDL/CDLF42 Series: 42 m³/h Design Flow (Selection)

ModelFlow Q (m³/h)Head H (m)Power P (kW)Stages
80CDL/CDLF42-1042417.510
80CDL/CDLF42-2042811520
80CDL/CDLF42-30421222230
80CDL/CDLF42-40421623040
80CDL/CDLF42-50422033750
80CDL/CDLF42-60422474560
80CDL/CDLF42-70421423070
80CDL/CDLF42-80421623080
80CDL/CDLF42-90421833790
80CDL/CDLF42-1004220337100
80CDL/CDLF42-1104222545110
80CDL/CDLF42-1204224745120

3.8 100CDL/CDLF65 & CDLF85 Series: High-Flow Configurations (Selection)

ModelFlow Q (m³/h)Head H (m)Power P (kW)Stages
100CDL/CDLF65-1065205.510
100CDL/CDLF65-2065401120
100CDL/CDLF65-30656018.530
100CDL/CDLF65-4065802240
100CDL/CDLF65-50651023050
100CDL/CDLF65-60651243760
100CDL/CDLF65-70651464570
100CDL/CDLF85-1085207.510
100CDL/CDLF85-2085411520
100CDL/CDLF85-3085642230
100CDL/CDLF85-4085863040
100CDL/CDLF85-50851103750
100CDL/CDLF85-60851344560

Note: All performance data represents nominal values at rated voltage, frequency, and clean water conditions (ρ = 1000 kg/m³, 20°C). Efficiency values represent pump hydraulic efficiency at the Best Efficiency Point. Height and weight data refer to standard motor configurations; actual dimensions vary with motor manufacturer and special executions.

4. Structural Design & Material Engineering

4.1 Stamped Stainless Steel Construction

The CDL/CDLF series employs a revolutionary manufacturing process that replaces conventional sand casting with precision sheet metal stamping and welding:

ComponentManufacturing MethodMaterialAdvantage
ImpellerDeep drawing + stampingAISI 304/316 stainless steelPrecise vane geometry; balanced mass distribution; smooth surface (Ra ≤ 1.6 μm)
DiffuserStamping + weldingAISI 304/316 stainless steelAccurate flow channel dimensions; minimal hydraulic losses
Pump Casing (internal)Stamping + weldingAISI 304/316 stainless steelUniform wall thickness; no casting defects (porosity, sand inclusions)
Inlet/Outlet (CDL)CastingCast iron (EN-GJL-200)Cost-effective; adequate strength for flanged connections
Inlet/Outlet (CDLF)Stamping + weldingAISI 304/316 stainless steelFull corrosion resistance; hygienic surface finish

Critical Advantages Over Cast Construction: Dimensional accuracy (stamping tolerances of ±0.1 mm vs. ±1.0 mm for sand casting), superior surface finish (Ra ≤ 1.6 μm vs. Ra ≥ 6.3 μm for cast surfaces), material consistency (no casting segregation or porosity), and 30–40% weight reduction for equivalent hydraulic performance.

4.2 Vertical Inline Configuration

The CDL/CDLF series features a vertical inline design with the motor mounted directly above the pump:

  • Compact footprint: Pump and motor share the same vertical axis; minimal floor space requirement
  • Simplified piping: Inlet and outlet flanges are aligned on the same vertical plane; straight-through piping configuration
  • Easy maintenance: Motor removal does not disturb piping; cartridge seal replacement without pump disassembly
  • Stable operation: Vertical shaft alignment eliminates coupling misalignment issues inherent in horizontal split-case designs

4.3 Mechanical Seal & Bearing System

ComponentSpecificationFunction
Mechanical SealSilicon Carbide (SiC) vs. Carbon or SiC vs. SiCHigh-pressure sealing; wear-resistant; chemical compatible
Seal ConfigurationSingle mechanical seal (standard); double mechanical seal (optional)Leak prevention; barrier fluid protection
Upper BearingDeep-groove ball bearing (radial load)Supports rotor weight and radial hydraulic forces
Lower BearingAngular contact ball bearing (thrust load)Absorbs axial thrust from multistage impeller arrangement
Bearing LubricationGrease (standard); oil (high-temperature option)Long life; minimal maintenance

The multistage impeller arrangement generates significant axial thrust proportional to the pressure differential across each stage: 
Faxial = ΔP × Aimpeller eye × n 
The lower angular contact bearing is specifically sized to absorb this cumulative thrust load across all stages.

5. Motor Engineering & Drive Options

5.1 Standard Motor Configuration

ParameterSpecification
Motor TypeTEFC (Totally Enclosed Fan Cooled) three-phase induction motor
Efficiency ClassIE2 (standard); IE3 (premium efficiency option)
Insulation ClassF (155°C)
Protection ClassIP55
Voltage / Frequency380 V / 50 Hz (standard); 220 V, 415 V, 460 V, 660 V; 60 Hz (optional)
CoolingExternal fan (IC411)
MountingB5 (flange mounted) standard

5.2 Variable Frequency Drive (VFD) Compatibility

The CDL/CDLF series is fully compatible with VFD operation for energy-efficient flow control:

Affinity Laws for VFD Operation:

Q2 = Q1 × (f2 / f1) 
H2 = H1 × (f2 / f1)2 
P2 = P1 × (f2 / f1)3

Where f = motor supply frequency (Hz).

Energy Savings Example: 
For a HVAC booster system requiring 70% of design flow for 50% of operating hours: 
P70% = P100% × (0.7)3 = P100% × 0.343 
Energy savings = 65.7% during reduced-flow periods compared to throttling control.

VFD Minimum Frequency: Do not operate below 30 Hz (60% of rated speed) to maintain adequate bearing lubrication and cooling fan effectiveness.

6. Application Engineering & Selection Guidelines

6.1 Duty Point Selection

The optimal pump selection positions the system operating point at or near the Best Efficiency Point (BEP):

Qoperating ≈ 0.8 × QBEP to 1.1 × QBEP

Operating outside this range results in: 
Left of BEP (low flow): Increased radial thrust on impeller; higher bearing loads; recirculation losses; potential vibration 
Right of BEP (high flow): Increased NPSH requirements; potential cavitation; reduced head; higher power consumption

6.2 System Head Calculation

For pressure boosting applications, the required pump head is:

Hpump = Hstatic + Hfriction + Hpressure + Hvelocity − Hsuction

Where: 
Hstatic = Elevation difference between suction and discharge water levels (m) 
Hfriction = Total pipe friction loss (m) 
Hpressure = Required discharge pressure head (m) = Prequired / (ρg) 
Hvelocity = Velocity head at discharge (m) 
Hsuction = Suction pressure head (m); positive for flooded suction, negative for suction lift

6.3 Parallel Pump Operation

For systems requiring variable flow or redundancy, multiple CDL/CDLF pumps can operate in parallel:

  • Identical pumps only: Pumps must have identical head-flow curves
  • Common discharge header: Each pump requires an individual check valve
  • Staggered startup: Sequential start with time delay to minimize inrush current
  • Flow addition: Qtotal = Q1 + Q2 + ... + Qn at constant head

Note: Operating dissimilar pumps in parallel will cause the higher-head pump to throttle the lower-head pump, potentially resulting in reverse flow through the weaker unit.

6.4 Typical Application Scenarios

ApplicationRecommended Model RangeKey Selection Criteria
High-rise building water supply32CDLF4-10 to 65CDLF20-10High head for vertical lift; constant pressure with VFD
Boiler feed water25CDLF2-15 to 50CDLF12-12High temperature capability; NPSH verification; reliability
Reverse osmosis pre-treatment25CDLF2-10 to 40CDLF8-8Moderate flow, high pressure; stainless steel for corrosion
HVAC chilled/hot water circulation40CDLF8-5 to 80CDLF42-20Energy-efficient VFD operation; quiet operation
Industrial process water50CDLF16-5 to 100CDLF65-30Chemical compatibility; continuous duty; high reliability
Water treatment (UF/RO/NF)25CDLF2-20 to 50CDLF12-15High pressure for membrane filtration; sanitary construction
Fire suppression jockey pump32CDLF4-8 to 50CDLF12-8Maintain system pressure; automatic start on pressure drop
Irrigation & sprinkler systems40CDLF8-5 to 65CDLF20-5Moderate head for sprinkler pressure; corrosion resistance
Pharmaceutical CIP/SIPCDLF full 316 SS constructionFDA compliance; electropolished surfaces; validated cleaning
Food & beverage processingCDLF full 316 SS constructionHygienic design; 3A compliance; crevice-free construction

7. Installation, Operation & Maintenance

Installation & Maintenance

7.1 Installation Requirements

ParameterRequirement
FoundationRigid, level concrete base; anchor bolts for vibration isolation
Piping AlignmentNo pipe strain on pump flanges; use flexible connectors if necessary
Suction ConditionsFlooded suction preferred; if suction lift required, verify NPSHa > NPSHr + 0.5 m
Discharge PipingMinimum pipe size equal to pump outlet; avoid abrupt diameter changes
Electrical SupplyProperly sized cables; circuit breaker with motor overload protection
Ambient Conditions≤ +40°C; adequate ventilation for motor cooling
Vibration IsolationSpring isolators recommended for installations above occupied spaces

7.2 Commissioning Procedure

  • Pre-startup inspection: Verify piping connections, electrical supply, rotation direction
  • Priming: Ensure pump and suction line are fully filled with liquid
  • Venting: Open air vents at pump casing high points until liquid flows
  • Jog start: Brief motor energization to verify correct rotation (clockwise viewed from motor end)
  • Full startup: Monitor pressure, current, vibration, and noise during initial operation
  • Performance verification: Compare operating pressure and flow to design specifications

7.3 Maintenance Protocol

Inspection ItemFrequencyAction
Mechanical seal leakageMonthlyReplace if drip rate exceeds 5 drops/minute
Bearing temperatureMonthlyInvestigate if >80°C or ΔT >15°C from ambient
Vibration analysisQuarterlyISO 10816 criteria; investigate if velocity >4.5 mm/s RMS
Motor current drawMonthlyCompare to nameplate; investigate deviations >10%
Coupling alignmentAnnuallyVerify within 0.05 mm parallel and angular tolerance
Impeller wearAnnuallyInspect for erosion, corrosion, or cavitation damage
Seal chamber conditionAnnuallyReplace barrier fluid if contaminated (double seal systems)

8. Ordering Information & Custom Engineering

8.1 Required Specification Data

ParameterExample Value
Pump Model40CDLF8-10
Fluid TypePotable water / RO permeate / Chilled water
Flow Rate (Q)8 m³/h
Total Dynamic Head (H)90 m
Fluid Temperature≤ 40°C
Fluid pH6.5 – 8.5
Suction ConditionsFlooded suction at 2 m above pump inlet
Discharge Pressure Required8.5 bar
Voltage / Frequency380 V / 50 Hz / Three-phase
Material SpecificationCDLF (full AISI 304)
Seal MaterialSiC/Carbon with EPDM elastomers
Connection TypeFlanged DN40 (PN16)
VFD RequiredYes / No

8.2 Custom Engineering Options

  • AISI 316 full construction: Enhanced chloride resistance for seawater, brine, and aggressive chemical applications
  • High-temperature execution: Up to +180°C with special seals and cooling modifications
  • Double mechanical seal: Barrier fluid system for hazardous, valuable, or crystallizing fluids
  • Special surface finish: Electropolished to Ra ≤ 0.4 μm for pharmaceutical and biotechnology applications
  • Special voltages/frequencies: 220 V, 415 V, 460 V, 575 V; 60 Hz designs for North American and export markets
  • Explosion-proof motors: ATEX/IECEx certified motors for Zone 1/Zone 2 hazardous areas
  • Special mechanical seals: PTFE-wedge seals for high-temperature or chemically aggressive media

9. Why Choose CDL/CDLF Series for Your Pressure Boosting Needs?

Engineering CriterionCDL/CDLF Series Advantage
Hydraulic EfficiencyStamped impellers achieve 72–87% efficiency; 5–10% higher than cast equivalents
Corrosion ResistanceFull AISI 304/316 stainless steel eliminates rust and scaling
Compact FootprintVertical inline design minimizes floor space; ideal for equipment rooms
Quiet OperationPrecision-balanced stamped rotors reduce vibration and noise
Energy SavingsVFD-compatible for variable-flow systems; affinity law cubic power reduction
Maintenance AccessibilityCartridge seal and motor removal without piping disassembly
Pressure CapabilityMultistage configuration achieves 250 m head in compact envelope
Hygienic DesignSmooth stamped surfaces; crevice-free construction; CIP/SIP compatible
Global ComplianceISO 2858, ISO 5199, GB/T 5657 certified for international projects

Get a Free Custom Quote for CDL/CDLF Multistage Pumps

Choose TITECHO's CDL/CDLF series for superior hydraulic efficiency, stainless steel durability, and reliable pressure boosting. Our team responds within 24 hours!

📞 +86 13305761511

✉️ info@cntecho.com

💬 WhatsApp: Nancy / Jahor

Get Free Custom Quote Now → 

LATEST

INFORMATION

Get the latest product information of the company

%{tishi_zhanwei}%

CONTACT US

Telephone: +86 13305761511
Email: info@cntecho.com

Add: RM. 602, BUILDING B, NO.1551 SHUANGSHUI RD., LUQIAO DIST., TAIZHOU CITY, ZHEJIANG, CHINA

 


Copyright © 2026 TECHO ELECTRICAL & MECHANICAL (TAIZHOU) CO., LTD. All Rights Reserved.

Business License