Introduction

The brushed DC motor is the oldest and most fundamental form of rotary electromechanical energy converter still in widespread use today. Invented in the early 19th century and refined through generations of engineering, it remains the go-to solution for applications requiring simple control, high starting torque, and minimal system cost.

This article provides a comprehensive technical overview of brushed DC motor principles, construction, commutation physics, speed control methods, and the engineering trade-offs that determine when a brushed motor is the optimal choice.

1. Operating Principle: The Lorentz Force

At the heart of every DC motor lies the Lorentz Force Law, which describes the mechanical force experienced by a current-carrying conductor in a magnetic field:

F=B·I·L

Where: 
F = Force on conductor (Newton, N) 
B = Magnetic flux density (Tesla, T) 
I = Current through conductor (Ampere, A) 
L = Active conductor length in magnetic field (meter, m)

The direction of this force is determined by Fleming's Left-Hand Rule: extend the thumb, index finger, and middle finger of your left hand mutually perpendicular. The index finger points in the direction of the magnetic field, the middle finger in the direction of current, and the thumb indicates the direction of the resulting force.

In a practical motor, multiple conductors are wound around a laminated iron core (the armature or rotor) and placed within a stationary magnetic field. The collective force on all active conductors produces a driving torque that rotates the armature.

2. Construction and Components

A brushed DC motor consists of five essential components:

ComponentFunctionMaterial
Stator (Yoke)Provides magnetic flux pathCast iron or steel
Field Windings / PMGenerates stationary magnetic fieldCopper wire or permanent magnets
Armature (Rotor)Rotating component with current-carrying conductorsLaminated silicon steel + copper windings
CommutatorMechanical current reverserCopper segments insulated by mica
BrushesSliding electrical contact to commutatorCarbon, graphite, or metal-graphite composite

The Commutator: Mechanical Intelligence

The commutator is a segmented copper cylinder mounted on the rotor shaft. Each segment connects to a specific armature coil. As the rotor turns, the brushes slide across the commutator surface, sequentially connecting different coils to the power supply. This mechanical switching action ensures that current always flows in the correct direction to maintain continuous rotation.

Key Insight: The number of commutator segments equals the number of armature coils. More segments produce smoother torque with reduced ripple.

3. Fundamental Equations

Back EMF

As the armature rotates, its conductors cut through the magnetic field, inducing an electromotive force (EMF) by Faraday's Law. This back EMF ($E_b$) opposes the applied voltage:

Eb=(P·Φ·Z·N)/(60·A)

Where: 
P = Number of poles 
Φ = Flux per pole (Weber, Wb) 
Z = Total number of armature conductors 
N = Rotational speed (RPM) 
A = Number of parallel paths in armature winding

For practical engineering, this simplifies to:

Eb=Ke·Φ·N

Where Ke is the back EMF constant (V·min/rpm or V·s/rad).

Voltage Equation

Applying Kirchhoff's Voltage Law to the armature circuit:

V=Eb+Ia·Ra+Vbrush

Where: 
V = Applied terminal voltage (V) 
Ia = Armature current (A) 
Ra = Armature resistance (Ω) 
Vbrush = Brush contact voltage drop (typically 0.5–2 V per brush set)

Critical Startup Condition: At standstill ($N=0$), back EMF is zero. The starting current is limited only by Istart=V/Ra, which can be 10–20× the rated current. This is why starting resistors or electronic current limiting are essential.

Torque Equation

The electromagnetic torque developed is:

T=Kt·Φ·Ia

For permanent magnet (PM) brushed motors (where $\Phi$ is constant):

T=Kt·Ia

This linear torque-current relationship makes PM brushed motors exceptionally predictable and easy to control—ideal for servo applications and simple speed regulation.

Speed Equation

Rearranging the voltage equation:

N=(V - Ia*Ra - Vbrush)/(Ke*Φ)

Or equivalently:

N=V/(Ke*Φ)-(Ra/(Ke*Kt*Φ^2))*T

This reveals the two primary methods of speed control: 
• Armature voltage control: Reducing $V$ decreases speed while maintaining torque capability 
• Field flux control: Weakening $\Phi$ increases speed at the expense of torque

4. Types of Brushed DC Motors

Brushed motors are classified by how their magnetic field is produced:

TypeField ExcitationTorque CharacteristicSpeed RegulationTypical Applications
Permanent Magnet (PM)Fixed permanent magnetsT∝Ia (linear)Good (±5–10%)Servos, fans, pumps, power tools
Series-WoundField in series with armatureT∝Ia^2 (very high starting torque)Poor (dangerous no-load speed)Cranes, hoists, starter motors, traction
Shunt-WoundField in parallel with armatureT∝Ia (stable)Excellent (±2–5%)Machine tools, conveyors, mills
Compound-WoundBoth series and shunt fieldsBalanced characteristicModerateRolling mills, elevators, presses

Permanent Magnet DC Motors

PM motors dominate modern low-to-medium power applications because they eliminate the field winding losses and complexity of wound-field designs. Key advantages include:

  • Higher efficiency (no field copper losses)
  • Linear torque-speed characteristic
  • Smaller size and lighter weight for equivalent output
  • No risk of runaway (unlike series motors)

5. Performance Characteristics

Torque-Speed Curve

The torque-speed relationship of a brushed DC motor is fundamentally linear:

N=Nno-load-(Ra/(Ke*Kt*Φ^2))*T
Operating PointConditionCharacteristic
No-load speedT=0Maximum speed; minimum current ($I_0$ = friction/windage losses only)
Rated loadT=TratedRated speed; rated current; maximum continuous efficiency
Stall (locked rotor)N=0Maximum current; maximum torque; zero output power
Maximum powerT=Tstall/2Pmax=Tstall*ωno-load/4
Maximum efficiencyNear rated loadTypically 75–85% for standard designs; up to 90% for premium PM motors

Efficiency and Power Flow

η=(Pout/Pin)*100%=(Tsh*ω/(V*I))*100%
StageExpressionDescription
Electrical InputPin=V*ITotal power from supply
Armature Copper LossIa^2*RaResistive heating in windings
Brush Contact LossVbrush*IaVoltage drop at brush-commutator interface
Field Loss (wound-field)Ia^2*RaExcitation winding losses
Developed PowerEb*IaElectromechanical conversion
Rotational LossesPfriction+Pwindage+PcoreMechanical and magnetic losses
Mechanical OutputPout=Tsh*ωUsable shaft power

Example Calculation

Consider a 24 V PM brushed motor with: 
Ra=0.8 Ω
Ke=0.05 V·min/rpm (=0.477 V·s/rad)
Kt=0.477 N·m/A
Brush drop = 1.5 V 
No-load current = 0.5 A 
Rated current = 10 A

At rated load:

  • Back EMF: Eb=24-10*0.8-1.5=14.5 V
  • Speed: N=14.5/0.05=290 RPM
  • Torque: T=0.477*10=4.77 N·m
  • Output power: Pout=4.77*(290*2*Pi/60)
  • Input power: Pin=24*10=240 W
  • Efficiency: eta=144.8/240*100%=60.3%

Note: This relatively low efficiency is typical for small brushed motors. Larger, optimized designs achieve 75–85%.

6. Speed Control Methods

Armature Voltage Control

The most common and effective method. By varying the applied voltage below the rated value:

N ∝ V (at constant torque)

Implementation methods:

MethodEfficiencySpeed RangeCostComplexity
Rheostat30–70%2:1LowVery low
PWM Drive85–95%100:1MediumMedium
SCR Phase Control70–85%10:1Low-MediumLow

Field Flux Control

Applicable only to wound-field motors. By inserting a variable resistor in series with the shunt field winding, the field current (and thus flux) is reduced:

N ∝ 1/Φ

This method increases speed above the base (rated) speed, but torque capability decreases proportionally. It is commonly used in constant-power applications such as machine tool spindles.

7. Commutation and Brush Wear

The Commutation Process

Commutation is the process of reversing current direction in an armature coil as it passes from one pole to the next. Ideally, this reversal is instantaneous. In practice:

  • Sparkless commutation requires the current to reverse while the coil is temporarily short-circuited by the brush spanning two adjacent commutator segments.
  • Reactance voltage ($L\frac{dI}{dt}$) opposes this rapid current change, causing arcing.
  • Interpoles (commutating poles) are small auxiliary windings placed between main poles to generate a counter-flux that neutralizes reactance voltage.

Brush Materials and Selection

MaterialCompositionAdvantagesDisadvantagesApplications
ElectrographitePure graphiteLow friction; self-lubricating; low noiseHigher resistivity; limited current densitySmall motors; precision instruments
Carbon-GraphiteCarbon + graphiteGood wear; moderate costModerate current capacityGeneral purpose; automotive
Electrographite-CopperGraphite + copperHigh current density; low voltage dropHigher friction; more wearPower tools; traction
Metal-GraphiteCopper + graphiteVery high current; low contact resistanceRapid commutator wear; sparkingHigh-current industrial

Factors Affecting Brush Life

FactorImpact on LifeMitigation
Current densityHigher density → faster wearStay within manufacturer ratings (typically 5–15 A/cm²)
Commutator surface speedHigher speed → increased mechanical wearLimit to 15–40 m/s depending on brush grade
HumidityToo dry → increased friction; too humid → electrolytic corrosionMaintain 40–60% RH
VibrationCauses chattering and uneven wearProper mounting; balanced rotor
ContaminationDust, oil, chemicals degrade brushesSealed enclosures; regular cleaning

Typical brush life ranges from 500 to 5,000 hours depending on operating conditions.

8. Advantages and Limitations

Why Choose Brushed DC?

AdvantageTechnical BasisPractical Benefit
Simple controlTorque ∝ current; speed ∝ voltageNo complex electronics required
Low system costNo controller needed for basic operationReduced BOM cost
High starting torqueSeries-wound: T ∝ Ia^2Direct starting under heavy loads
Wide speed rangeVoltage control from 0 to ratedEasy speed trimming
Linear characteristicPM motors: predictable T-N curveSimple feedback control
Rugged and repairableBrushes and commutator are serviceableField maintenance possible

Key Limitations

LimitationCauseConsequence
Brush wearMechanical friction and electrical erosionPeriodic maintenance; limited life
Commutator sparkingInductive switching; imperfect commutationEMI/RFI generation; fire hazard in explosive atmospheres
Speed ceilingMechanical commutation limitsTypically < 5,000–8,000 RPM
Efficiency ceilingBrush voltage drop + friction5–15% lower than brushless equivalent
Dust/debris sensitivityOpen commutator designRequires protected environment
Acoustic noiseBrush-commutator interaction; sparkingUnsuitable for quiet applications

9. Brushed vs. Brushless: Selection Guide

ParameterBrushed DC MotorBrushless DC Motor
CommutationMechanical (brushes + commutator)Electronic (controller + sensors)
Typical Efficiency50–75%80–95%
Life Expectancy500–5,000 hours (brush-dependent)10,000–50,000+ hours
Maximum Speed~5,000–8,000 RPM>15,000 RPM
Starting TorqueVery high (series-wound)High
Speed-Torque LinearityExcellent (PM type)Excellent
Electrical Noise (EMI)High (brush arcing)Negligible
MaintenanceBrush replacement requiredBearing lubrication only
Controller RequiredNo (for basic operation)Yes (mandatory)
Upfront CostLowestHigher
Total Cost of OwnershipHigher (maintenance + energy)Lower (long life + efficiency)
Explosion SafetySpark hazardInherently safe

When to Choose Brushed

Application ConditionRecommended Choice
Intermittent duty (< 500 hrs/year)Brushed
Cost-sensitive, high-volume consumer productBrushed
Simple speed control, no electronics budgetBrushed
Very high starting torque requiredBrushed (series-wound)
Field serviceability requiredBrushed
Speed < 3,000 RPM, torque > 5 N·mBrushed

10. Modern Developments

Despite the dominance of brushless technology, brushed DC motors continue to evolve:

InnovationBenefit
Silver-graphite brushes30% longer life; lower contact resistance
Self-lubricating commutatorsReduced maintenance intervals
Rare-earth PM rotorsHigher power density; improved efficiency
Integrated PWM drivesBrush motor + controller in one package
Sealed commutator designsIP54+ rating for harsh environments

Conclusion

The brushed DC motor remains a viable and often optimal solution for applications where simplicity, cost, and high starting torque outweigh the benefits of brushless technology. Understanding the fundamental equations—back EMF, torque production, and the voltage balance—enables engineers to select, size, and control brushed motors effectively.

While brushless motors dominate continuous-duty, high-speed, and high-efficiency applications, the brushed DC motor's straightforward operation and minimal system complexity ensure its continued relevance in the electromechanical landscape.

LATEST

INFORMATION

Get the latest product information of the company

%{tishi_zhanwei}%

CONTACT US

Telephone: +86 13305761511
Email: info@cntecho.com

Add: RM. 602, BUILDING B, NO.1551 SHUANGSHUI RD., LUQIAO DIST., TAIZHOU CITY, ZHEJIANG, CHINA

 


Copyright © 2026 TECHO ELECTRICAL & MECHANICAL (TAIZHOU) CO., LTD. All Rights Reserved.

Business License

Search for the product name you want to search

TECHO ELECTRICAL & MECHANICAL

%{tishi_zhanwei}%